background image

 

 

BK 476 Specific  

8 Further information for all stove owners  

8.1 Reduced burning (Slow combustion)…………………………...   

8.2 Over firing………………………………………………………….    

8.3 Chimney fires……………………………………………………... 

8.4 Periods of non-use (Summer months)………………………….   

8.5 Ash removal ……………………………………………………...  

8.6 Replacement parts……………………………………………….     

8.7 Classification……………………………………………………… 

8.8 Adverse weather conditions……………………………………..

 

8.9 Door glass…………………….………………………………….. 

8.10 Fire door handle ……………………………………………….. 

8.11 Storage cupboard/compartment………………………………. 

 

9 How heat is delivered by your stove  

9.1 Radiant heat …………………………………………………….. 

 

10 Care for your Arada stove  

10.1 Liners / firebricks ……………………………………………… 

10.2 Throat plate …………………………...………………………. 

10.3 Fire door seal …………………………………………………… 

10.4 Cracked glass …………………………………………………. 

10.5 Chimney / flue sweeping ………………………………………. 

 

11 Further resources / reading 

 

11.1 Information………………………………………………………. 

11.2 Specifications …………………………………………………...

 

 

12 Guarantee  

12.1 Guarantee ………………………………………………………. 

12.2 Terms and Conditions …………………………………………. 

12.3 General ………………………………………………………….. 

 

13 Technical data

…………………………………………………….  

 

14 Notes 

………………………………………………………………. 

 

 

Page 4 

LAGOM Stove User Guide 

 

19 

19 

19 

19 

20 

20 

20 

21 

21 

21 

21 

 

 

22 

 

 

23 

23 

23 

24 

24 

 

 

25 

25 

 

 

26 

27 

28 

 

29 

 

30-31 

 

Содержание Lagom

Страница 1: ...PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE BK 746 SPECIFIC Rev 01 ISSUE DATE 05 10 2020 EN 13240 2011 A2 2004 Lagom Stove User Guide Lagom...

Страница 2: ...ave any questions about your stove which are not covered by this manual please contact the Arada retailer in your area call our technical support department on 44 0 1297 632050 or visit our website ww...

Страница 3: ...warnings 2 2 Health and safety 4 Recommended fuels 4 1 Wood 5 Before using your stove 6 Air inlet controls 6 1 Air inlet 6 1 1 Air control location 6 1 2 Air control 7 Lighting your stove 7 1 1 Smoke...

Страница 4: ...8 11 Storage cupboard compartment 9 How heat is delivered by your stove 9 1 Radiant heat 10 Care for your Arada stove 10 1 Liners firebricks 10 2 Throat plate 10 3 Fire door seal 10 4 Cracked glass 1...

Страница 5: ...rnal Rear Flue Outlet Behind Knock Out Rear Cover NOTE Top rear flue outlets are interchangeable will depend upon installation requirements Fire Door Assembly Fire Door Handle Socket LAGOM Stove User...

Страница 6: ...ss LAGOM Stove User Guide Page 6 BK 746 Specific 1 2 Identifying parts terminology of your stove Internal Throat Plates Upper metal lower ceramic Ash Pan Location Below grate area Storage Cupboard Gra...

Страница 7: ...E NOTE This additional information is to be read in addition to BK545 Dry Stove Installation Guide 2 1 Stove clearances dimensions Minimum Distance To Combustible Materials A B C D 100mm 100mm 800mm 1...

Страница 8: ...l building standards in force Floor protection Minimum dimensions Distances can be increase from stated Stove Protection Plate A B 100mm 257mm Corner installation clearances to combustible materials F...

Страница 9: ...LAGOM Stove User Guide 2 4 Stove dimensional drawing BK 746 Specific Page 9 Secondary Primary Air Control External Air Connection 125mm...

Страница 10: ...xternal air connection is required for installation then a suitable supply duct of 125mm diameter in metal construction is recommended External Air Connection Rear Default External Air Connection Base...

Страница 11: ...um coke or Bituminous house coal must NOT be burned in this appliance The use of these fuels will invalidate the appliance guarantee Please ensure that the air inlet vent grills to the dwelling are no...

Страница 12: ...east 24 months in the case of hard wood We recommend using dry logs with a diameter of 5 8cms and length of 20 25cms If when burning wood you see signs of sticky tar inside the appliance or chimney yo...

Страница 13: ...the installation fitter Consideration must be given for the need for extra ventilation if another heating source needing air is to be operated simultaneously If an extraction fan is proposed to be fi...

Страница 14: ...e direct air feed ducting requirements NOTE DO NOT COVER OR PARTIALLY OBSTRUCT THE AIR INLET OPENINGS FOR THE APPLIANCE 6 1 1 Air control location The air control regulates the air entering the fire b...

Страница 15: ...ce and is located centrally below the fire door Pulling the control lever out achieves the fully open position see Figure 1 Pushing the control lever in will reduce the air or shut down the stove as s...

Страница 16: ...quires a good supply of air coming from above the fuel For this reason we open the air inlet fully while igniting the stove then reduce this once the burn is well formed As much as 40 of the heat from...

Страница 17: ...r during the transition period i e when the outside temperature is higher than 15o C during rainy and humid days or wind gusts During this period the fireplace stove should be operated with the minimu...

Страница 18: ...urning material in the fire bed to light a new fuel charge excessive smoke emission can occur Refuelling must be carried out onto a sufficient quantity of glowing embers and ash that the new fuel char...

Страница 19: ...arts body paint which has turned dusty white is also indicative of such use 8 3 Chimney fires Used in the correct manner with the correct fuel and regular maintenance a chimney fire should never occur...

Страница 20: ...Replacement parts Genuine replacement spare parts can be obtained from www aradastovesandspares com You can find a complete list of spares and consumables such as liners grate and throat plates as wel...

Страница 21: ...t blackened To remedy this operate the appliance at a fast rate Alternatively when the stove is cold open the door and clean the inside face of the glass with a damp cloth or with glass cleaner www ar...

Страница 22: ...ss and less intense the further you move away from the stove This radiated heat is delivered as infrared rays heat the objects they strike It is then these objects such as the chimney breast hearth et...

Страница 23: ...ate correctly there is no need to replace them Cracked liners will not in themselves effect the performance of the stove 1 Incline and remove the throat plate 3 2 Incline and remove the side bricks 2...

Страница 24: ...rebox and it may fail completely leading to personal injury or a fire You should discontinue use of your stove until it has been repaired You can source replacement glass kits from www aradastovesands...

Страница 25: ...er more information about your stove and associated articles Arada Technical Support 01297 632052 technical aradastoves com Arada Stoves Support Site www aradastoves com support Competent Person Schem...

Страница 26: ...use The following guarantee periods shall apply in respect of the following Arada stoves The Arada Lagom comes with a 10 year guarantee to the main body The external paint finish carries a one year g...

Страница 27: ...ered by this guarantee Firebox linings Grate Fuel retainer Throat plate Gaskets Door glass Seals 9 The guarantee does not cover damage caused by storing or using the stove in a damp environment defect...

Страница 28: ...ng Standards offices or a Citizens Advice Bureau If you believe your appliance is not working correctly or it has broken components in the first instance please contact your local retailer or installe...

Страница 29: ...6 Minimum Distance to Combustible Materials Single Walled Flue mm 100 Rear 100 Side Weight Packed Kg 123 Nominal Heat Output Wood Kw 4 0 Efficiency Nett 80 5 Mean Flue Gas Temperature C 247 Mean CO E...

Страница 30: ...LAGOM Stove User Guide 14 Notes Page 30 BK 746 Specific...

Страница 31: ...BK 746 Specific Page 31 14 Additional Notes LAGOM Stove User Guide...

Страница 32: ...6 Specific Arada Ltd The Fireworks Weycroft Avenue Axminster Devon EX13 5HU United Kingdom www aradastoves com T 44 0 1297 632050 Email info aradastoves com DATE OF ISSUE 05 10 2020 LAGOM Stove User G...

Отзывы: