BK 746 Specific   

Page 26 

LAGOM Stove User Guide 

12 Guarantee 

 

When you buy an Arada stove, you are not only buying a first class appliance, you are    

receiving a commitment from us to look after you and your appliance. 

 

12.1 Guarantee 

 

If any part of the main body of the stove fails due to a manufacturing or material defect  

during the guarantee period that applies in respect of the relevant stove (as set out        

below), Arada will, at its sole discretion, repair or replace your Arada stove for no charge. 

 

For the purposes of this guarantee, a material or manufacturing defect includes the      

splitting or cracking of the main body (defined as the steel outer casing and items fixed        

immovably to the casing). 

 

Damage caused by over-firing or over-heating is not covered (as described in the          

operation manual).  Warping and a red-oxide colouring will demonstrate the over-heating 

of internal parts; body paint which has turned dusty white is also indicative of such use. 

 

The following guarantee periods shall apply in respect of the following Arada stoves: 

 

The Arada Lagom comes with a 10 year guarantee to the main body. 

 

The external paint finish carries a one year guarantee only. 

 

This guarantee is subject to the Terms and Conditions set out below. 

 

12.2 Terms and Conditions 

 

The following terms and conditions must be satisfied in order for your stove to be covered 

by the guarantee set out above: 

 

1. Your stove must have been purchased from an officially approved Arada dealer. 

 

2. You must be the original purchaser of the stove in order to make a claim. This        

guarantee is not valid in relation to any claims made by someone who did not originally 

purchase the stove from Arada or an approved Arada dealer. 

 

3. Any claim under this guarantee must be made through the approved Arada dealer 

where the stove was purchased and accompanied by proof of purchase (e.g. a valid      

receipt). Stoves not purchased from an approved Arada dealer will not be covered by this          

guarantee. 

 

4. Your stove must be installed in the UK for this guarantee to be valid. Stoves installed 

outside of the UK will not be covered by this guarantee. 

 

Содержание Lagom

Страница 1: ...PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE BK 746 SPECIFIC Rev 01 ISSUE DATE 05 10 2020 EN 13240 2011 A2 2004 Lagom Stove User Guide Lagom...

Страница 2: ...ave any questions about your stove which are not covered by this manual please contact the Arada retailer in your area call our technical support department on 44 0 1297 632050 or visit our website ww...

Страница 3: ...warnings 2 2 Health and safety 4 Recommended fuels 4 1 Wood 5 Before using your stove 6 Air inlet controls 6 1 Air inlet 6 1 1 Air control location 6 1 2 Air control 7 Lighting your stove 7 1 1 Smoke...

Страница 4: ...8 11 Storage cupboard compartment 9 How heat is delivered by your stove 9 1 Radiant heat 10 Care for your Arada stove 10 1 Liners firebricks 10 2 Throat plate 10 3 Fire door seal 10 4 Cracked glass 1...

Страница 5: ...rnal Rear Flue Outlet Behind Knock Out Rear Cover NOTE Top rear flue outlets are interchangeable will depend upon installation requirements Fire Door Assembly Fire Door Handle Socket LAGOM Stove User...

Страница 6: ...ss LAGOM Stove User Guide Page 6 BK 746 Specific 1 2 Identifying parts terminology of your stove Internal Throat Plates Upper metal lower ceramic Ash Pan Location Below grate area Storage Cupboard Gra...

Страница 7: ...E NOTE This additional information is to be read in addition to BK545 Dry Stove Installation Guide 2 1 Stove clearances dimensions Minimum Distance To Combustible Materials A B C D 100mm 100mm 800mm 1...

Страница 8: ...l building standards in force Floor protection Minimum dimensions Distances can be increase from stated Stove Protection Plate A B 100mm 257mm Corner installation clearances to combustible materials F...

Страница 9: ...LAGOM Stove User Guide 2 4 Stove dimensional drawing BK 746 Specific Page 9 Secondary Primary Air Control External Air Connection 125mm...

Страница 10: ...xternal air connection is required for installation then a suitable supply duct of 125mm diameter in metal construction is recommended External Air Connection Rear Default External Air Connection Base...

Страница 11: ...um coke or Bituminous house coal must NOT be burned in this appliance The use of these fuels will invalidate the appliance guarantee Please ensure that the air inlet vent grills to the dwelling are no...

Страница 12: ...east 24 months in the case of hard wood We recommend using dry logs with a diameter of 5 8cms and length of 20 25cms If when burning wood you see signs of sticky tar inside the appliance or chimney yo...

Страница 13: ...the installation fitter Consideration must be given for the need for extra ventilation if another heating source needing air is to be operated simultaneously If an extraction fan is proposed to be fi...

Страница 14: ...e direct air feed ducting requirements NOTE DO NOT COVER OR PARTIALLY OBSTRUCT THE AIR INLET OPENINGS FOR THE APPLIANCE 6 1 1 Air control location The air control regulates the air entering the fire b...

Страница 15: ...ce and is located centrally below the fire door Pulling the control lever out achieves the fully open position see Figure 1 Pushing the control lever in will reduce the air or shut down the stove as s...

Страница 16: ...quires a good supply of air coming from above the fuel For this reason we open the air inlet fully while igniting the stove then reduce this once the burn is well formed As much as 40 of the heat from...

Страница 17: ...r during the transition period i e when the outside temperature is higher than 15o C during rainy and humid days or wind gusts During this period the fireplace stove should be operated with the minimu...

Страница 18: ...urning material in the fire bed to light a new fuel charge excessive smoke emission can occur Refuelling must be carried out onto a sufficient quantity of glowing embers and ash that the new fuel char...

Страница 19: ...arts body paint which has turned dusty white is also indicative of such use 8 3 Chimney fires Used in the correct manner with the correct fuel and regular maintenance a chimney fire should never occur...

Страница 20: ...Replacement parts Genuine replacement spare parts can be obtained from www aradastovesandspares com You can find a complete list of spares and consumables such as liners grate and throat plates as wel...

Страница 21: ...t blackened To remedy this operate the appliance at a fast rate Alternatively when the stove is cold open the door and clean the inside face of the glass with a damp cloth or with glass cleaner www ar...

Страница 22: ...ss and less intense the further you move away from the stove This radiated heat is delivered as infrared rays heat the objects they strike It is then these objects such as the chimney breast hearth et...

Страница 23: ...ate correctly there is no need to replace them Cracked liners will not in themselves effect the performance of the stove 1 Incline and remove the throat plate 3 2 Incline and remove the side bricks 2...

Страница 24: ...rebox and it may fail completely leading to personal injury or a fire You should discontinue use of your stove until it has been repaired You can source replacement glass kits from www aradastovesands...

Страница 25: ...er more information about your stove and associated articles Arada Technical Support 01297 632052 technical aradastoves com Arada Stoves Support Site www aradastoves com support Competent Person Schem...

Страница 26: ...use The following guarantee periods shall apply in respect of the following Arada stoves The Arada Lagom comes with a 10 year guarantee to the main body The external paint finish carries a one year g...

Страница 27: ...ered by this guarantee Firebox linings Grate Fuel retainer Throat plate Gaskets Door glass Seals 9 The guarantee does not cover damage caused by storing or using the stove in a damp environment defect...

Страница 28: ...ng Standards offices or a Citizens Advice Bureau If you believe your appliance is not working correctly or it has broken components in the first instance please contact your local retailer or installe...

Страница 29: ...6 Minimum Distance to Combustible Materials Single Walled Flue mm 100 Rear 100 Side Weight Packed Kg 123 Nominal Heat Output Wood Kw 4 0 Efficiency Nett 80 5 Mean Flue Gas Temperature C 247 Mean CO E...

Страница 30: ...LAGOM Stove User Guide 14 Notes Page 30 BK 746 Specific...

Страница 31: ...BK 746 Specific Page 31 14 Additional Notes LAGOM Stove User Guide...

Страница 32: ...6 Specific Arada Ltd The Fireworks Weycroft Avenue Axminster Devon EX13 5HU United Kingdom www aradastoves com T 44 0 1297 632050 Email info aradastoves com DATE OF ISSUE 05 10 2020 LAGOM Stove User G...