background image

AR BLUE CLEAN

8840 - 8860 - 8870 - 8880

Avoid vehicles transit on the high pressure hose.

While the machine is running do not cover it and avoid placing it where there’s low air
supply.

Avoid vehicles transit on the high pressure hose.

While the machine is running do not cover it and avoid placing it where there’s low air
supply.

If you are working indoors, it’s compulsory to install a fan to discharge the exhaust
gases outside.

The fan terminal must not be obstructed. Don’t leave the lance or any other object
near the exhaust outlet.

The nature of the gases as well as the high temperature are to be considered very
dangerous, the operator must thus be adequately informed in order to avoid being
scalded.

Don’t leave the machine outside when it rains or when the weather conditions are
bad. The operators must wear protection clothes while using the machine.

Do not leave the machine for more than 15 minutes working with the gun closed, the
water   temperature   would   increase   rapidly   causing   serious   damages   to   the   seal
system. 

Each time the machine has to be switched off blow off the hose residual pressure by
using the gun.

Don’t put the hands in front of the machine’s water jet while the machine is working.

Do not use different fuels other than the ones recommended by the manufacturer.

WARNING !

Don’t carry out any operation on the machine before having unplugged it.

Don’t carry out any unwary operation on the electric cable and make sure the same is not
damaged.

Never direct high pressure water jets towards people, animals, electrical installations or the
machine itself.

Use always only clean water. Dirty water and chemical corrosive products are harmful for the
machine.

The   machine   is   equipped   with   idle   wheels;   it   thus   recommendable   to   avoid   placing   the
machine on ramps or slanted floors. Do not tilt the machine by more than 20 °C (with full
tank).

It is forbidden to use plug extensions if the work environment is subject to water/humidity
presence which could cut the isolating conditions of the system. Always check the isolation of
the electric cable as well as  the equipment’s integrity.

In case an extension is required, be sure that plugs and sockets have a protection type IP65
and that the power cord complies with the table reported here below.

VOLTAGE V

EXTENSION LENGTH

CABLE SECTION

USE AND MAINTENANCE HANDBOOK                       

page 6 

https://www.kipogeorgiki.gr/

https://www.kipogeorgiki.gr/

Содержание BLUE CLEAN 8840

Страница 1: ...achine has been examined according to the Directive Machines 2006 42 2004 108 2006 95 and following changes and integrations Annovi Reverberi S p A SERVICE Dept Via Aldo Moro 40 42 41030 Bomporto MO I...

Страница 2: ...Declaration of conformity 18 1 GENERAL WARNINGS Congratulations for having chosen our new model of machine which underlines Your level of technical know how and good taste for design Innovation and t...

Страница 3: ...act immediately your dealer see fig 1 Don t leave the machine unattended in your work environment After the daily use it is recommended to keep the machine in a dry place protected from bad weather co...

Страница 4: ...230 50Hz 3 Max capacity L H 1260 1260 900 900 Gal h 333 333 238 238 Temperature T C 55 55 65 65 Water tank Liters 5 5 5 5 Fuel tank Liters 24 24 24 24 Detergent tank Liters 8 8 8 8 Dimensions H 1040 1...

Страница 5: ...ke sure that the machine is constantly supplied with water Dry working would cause serious damages to the machine seal system Electrical connections must be carried out by skilled trained personnel on...

Страница 6: ...al pressure by using the gun Don t put the hands in front of the machine s water jet while the machine is working Do not use different fuels other than the ones recommended by the manufacturer WARNING...

Страница 7: ...the lever pos 1 and the water jet will come out from the lance To stop the water jet just release the lever pos 1 Once you finished working release the lever rotate the switch pos A fig 8 and set it o...

Страница 8: ...UP After having installed the machine in order to operate it open the water supply faucet H The control panel has been designed to run the operations easily The knob A has three main functions Pos 1...

Страница 9: ...essure On the machine s board are found also 4 lighted leds which indicate the following functions This is lit when the machine is working It flashes if provided when the flame turns off inside the bo...

Страница 10: ...HELTER Once finished working after having discharged the remaining pressure in the hose and after having inserted the safety catch on the gun picture 4 pos 1 and 2 wind up the electrical hose and the...

Страница 11: ...Here below are listed all labels used and their meaning 8840 8860 8870 8880 5 Warning Do not direct the high pressure jet towards people animals or objects etc 2 Type of machine 6 Warning Outlet of hi...

Страница 12: ...achine you have bought has undergone a factory test which ensures correct running at standard conditions Beware In case the machine has been kept inoperative for a long time run some water through the...

Страница 13: ...tance between the electrodes must be of 3 mm If the distance must be adjusted unscrew glow plug screw pos E remove the glow plug udjust the distance to acheive the 3 mm distance Reassemble the glow pl...

Страница 14: ...e metals and plastics The oil found inside the pump is highly dangerous and pollutant and must not be wasted in the environment or poured into civic drains For further informations please contact your...

Страница 15: ...21 Motor fan 4 Boiler delivery hose 13 Electric motor 22 Burner motor 5 Boiler 14 Detergent intake hose 23 Fuel pump 6 High pressure hose 15 Detergent tap 24 Safety valve 7 Gun 16 Tank detergent hose...

Страница 16: ...AL CARD P1 PRESSURE SWITCH 40 BAR TR1 LOW PRESSURE TRANSFORMER GG FUEL FLOATING DEVICE TR2 ELECTRODES HIGH PRESSURE TRANSFORMER EV ELECTROVALVE TM THERMOSTAT MP PUMP MOTOR CO COMMUTATOR MB BURNER MOTO...

Страница 17: ...icient spark to the electrodes Defected flow meter and or pressure switch Motor pump joint Insufficient or non exhisting voltage Check Replace Clean or replace Replace Repalce Replace Replace Replace...

Страница 18: ...ve documents EN 60335 1 EN 60335 2 79 EN 55014 1 EN 55014 2 EN 61000 3 2 EN 61000 3 3 EN 61000 3 11 EN 60704 1 on the basis of the directives prescriptions 2006 42 CE 2006 95 CE 2002 95 CE 2002 96 CE...

Страница 19: ...AR BLUE CLEAN 8840 8860 8870 8880 USE AND MAINTENANCE HANDBOOK page 19 https www kipogeorgiki gr https www kipogeorgiki gr...

Страница 20: ...AR BLUE CLEAN 8840 8860 8870 8880 VIA ALDO MORO 40 42 41030 BOMPORTO MO ITALY supporth annovireverberi it USE AND MAINTENANCE HANDBOOK page 20 https www kipogeorgiki gr https www kipogeorgiki gr...

Отзывы: