Model 600A400
16
Rev A
Example:
To set the RF Gain to minimum, send the following command:
LEVEL:GAIN0<LF>
To set the RF Gain to 50%, send the following command:
LEVEL:GAIN50<LF>
To set the ALC Response Time to max, send the following command:
LEVEL:RESP7<LF>
2.4.6.6
Identity
Query to identify the 600A400.
Syntax:
*IDN?
Parameters:
None
Query only (always requires a ? character)
Response Format:
f,m,n,<LF>
Where:
f
= manufacturer
m
= model designation
n
= firmware revision
Example:
To get the identity of the 600A400, send the following command:
*IDN?<LF>
Response:
AR-RF/MICROWAVE-INST,XXXXXXXX,1.0<LF>
2.4.6.7
IO Board Firmware Revision
Query to get the firmware revision of the I/O Board.
Syntax:
*IOB?
Parameters:
None
Query only (always requires a ? character)
Response Format:
INTERFACE_BOARD_SW_REVx<LF>
Where:
x
= firmware revision
Example:
To get the firmware rev. of the I/O Board, send the following command:
*IOB?<LF>
Response:
INTERFACE_BOARD_SW_REV3.10<LF>