40T18G26A
3.2.8 RF
Connector
CAUTION:
Many small RF connectors appear to be similar. Pay special attention to
use only the proper mating connector for this unit.
3.3 FRONT PANEL FEATURES
(Refer to Figure 3-2 below).
1
11
6
7
8
10
12
9
5
3
2
4
STANDBY
POWER
MAIN
REMOTE
INHIBIT
LOCAL
EXIT
Model 40T18G26
40 Watts
18 - 26.5 GHz
OPERATE
Figure 3-2. TWTA Front Panel
Table 3-1. TWTA Front Panel Features
Label Title
Function
1
MAIN POWER
Switchable 16 A. circuit breaker; connects primary power to power supplies.
2.
OPERATE
Push-button; turns on high voltage when all faults and heater delay are cleared.
3.
STANDBY
Push-button; biases grid off and turns off high voltage.
4. ADJUST
Rotary knob used as an input device to change values of a variety of
parameters.
5. EXIT
Push-button; terminates various menu selection routines and returns to the
previous menu level.
6-9.
S1...S4
"Soft Key" push buttons; various menu selection functions.
10.
Display
Displays numerous parameter values and fault messages.
11. Keylock
Switch
Allows operator to inhibit the TWTA, to enable front panel control, or to enable
computer control.
12.
Emergency switch cover
Provides access to emergency bypass switches, which permit manual control
of the amplifier.
Rev C