![AR 10010475 Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/ar/10010475/10010475_operating-and-service-manual_2962269023.webp)
Page 3
40T18G26A
M1–M10
40 Watts CW
18GHz–26.5GHz
E
Package Alternatives. May select an alternative
from the following [E1C or (E1C and E2S) and/
or E3H]:
E1C Cabinet: Without outer enclosure for rack mount-
ing, size (W x H x D) 48.3 x 13.3 (3U) x 68.6 cm,
19.0 x 5.25 (3U) x 27 in, Subtract approximately
7 kg, 15 lbs, for removal of outer enclosure.
E2S
Slides: slides installed, add approximately 2 kg,
5 lbs.
E3H
Handles: Front pull handles installed.
P Primary
Power must select one primary power
from the following options [P1 or P2]:
P1 99-260
VAC, 50/60 Hz, single phase, 850VA
max.
P2
400V Europe 360-435 VAC, 3 phase, WYE (5
wire) 50/60 Hz, 850 VA max. CE marked to
comply with EMC European Directive 89/336/
EEC for operation inside a shielded room.
Model Configurations
S
Special Features: May select a special feature
(extra cost) from the following [(S1R or S3F)
and/or S2F and/or S5F and/or S4F]:
S1R
Reflected Power Port: Type K female connector
on rear panel. Forward and reflected sample
port calibration data supplied on disk in Excel
format at 51 points, evenly spaced over speci-
fied frequency response.
S2F Flatness: Flatness ± 4 dB max at rated power.
S2V
Video Pulse capability
S3F Reflected
power
port: type K female connector
on front panel. Forward and reflected sample
port calibration data supplied on disk in Excel
format at 51 points, evenly spaced over speci-
fied frequency response.
S4F RF
input
connector: On front panel, not on rear
panel.
S5F
Forward output sample port: On front panel,
not on rear panel.
To order AR Products, call 215.723.8181. For an applications engineer call:800.933.8181. Direct to Service call: 215.723.0275 or
email:
For Faxing Orders:866.859.0582 (Orders Only Please)
Approved for public release by AR RF/Microwave Instrumentation
072216
Model Number
Features
E
P
S
40T18G26A Base
model
P1
–
M1 E1C
P1 –
M2
E1C & E2S &
E3H
P1 –
M3
See individual Specification Sheet
M4 E1C
P1
S2F
M5 -
P1
S1R
M6 E1C
P1
S1R
M7
E1C & E2S &
E3H
P1 S1R
M8 -
P1
S2V
M9
E1C & E2S &
E3H
P2 S3F,
S5F,
S6F
M10
E1C & E2S
P1
S1R, S2F
Example: Model 40T18G26AM1 would have option E1C, no
outer enclosure.