Model 1000T2G8B
Rev -
15
System Shutdown Screen
- In the event of a system shutdown due to a fault, refer to Table 3-5. The MENU
screen is replaced by a screen indicating the nature of the fault. Softkey S4 (labeled OK) is implemented as a
reset key; pressing S4 brings back the MENU screens. Line 3 of MENU 1, which normally displays the
operational state of the TWTA, is used as a fault display line until the fault is cleared. Most faults turn HV
off. Faults that do not turn off HV are specified in Table 3-5. When such faults are cleared, the system will
automatically resume the standby state and users may again select the Operate mode.
Some faults (EXTERNAL INHIBIT) will turn off the grid of the tubes to disable RF output while the fault is
being displayed on the screen. HV will remain on during these faults. Once the fault is corrected, the fault will
clear and the system will turn RF back on automatically. This automatic return to operation is provided for
selected faults due to influences external to the TWTA.
Factory Service Screens
- A number of screens intended for factory service and calibration are behind
passwords and are not accessible to the user.
System Malfunction Screens
- A number of screens are reserved to display error messages. These messages
are not normally seen and indicate a malfunction of the TWTA. System malfunction messages include the
following:
Database corrupt
Communication failure
Cannot restore
CU line voltage too low to operate. System shutdown
In the event that one of these appears, shut off the TWTA and contact an authorized service representative
before proceeding.
CAUTION:
Attempts to operate the TWTA despite control unit problems may result
in loss of the static RAM database and calibration information.
Содержание 1000T2G8B
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 10: ......
Страница 18: ......
Страница 30: ...Model 1000T2G8B 16 Rev 3 5 REAR PANEL FEATURES Figure 3 3 Rear Panel Features...
Страница 40: ...Model 1000T2G8B 26 Rev...
Страница 44: ...Model 1000T2G8B 30 Rev...
Страница 46: ...Model 1000T2G8B 32 Rev...
Страница 50: ...Model 1000T2G8B 36 Rev...
Страница 51: ...Model 1000T2G8B Rev 37 5 3 BLOCK DIAGRAM 25 28005 000 RF Combiner for L Band A28005 004...
Страница 52: ...Model 1000T2G8B 38 Rev...
Страница 72: ......