background image

BW

S175 Simple Install Guide 

12 

If a water supply to downstream 

equipment is immediately 

needed, the storage tank can be 

quickly filled. 

v

Place in Service

Step 13

OPEN the Feed Suppy Valve and check for 

leaks. Allow time for the tank to fill before 

using connected equipment (this could take 30 

minutes to several hours depending on the 

tank capacity).

Step 13

v

Quick Tank Fill

Open Bypass

Simply OPEN the Bypass Valve and un-filtered 

water will flow directly into the storage tank. 

When the tank is full, or a desired level is 

reached, CLOSE the Bypass Valve. The system is 

now in normal operating mode and the 

optimized water will 

flow to the tank. 

IMPORTANT: Do not leave the system in 

bypass. This could result in damage to the 

downstream equipment.

Содержание OptiPure BWS175

Страница 1: ...mple Install Guide 970 09729 Rev A 03 19 2019 Aquion Inc All Rights Reserved Access manuals spec sheets and additional educational materials for foodservice water treatment at our website www optipure...

Страница 2: ...40 105 F 5 40 C 3 Maximum Relative Humidity 80 at 88 F 31 C 4 Installation Category II 5 Pollution Degree II 6 Indoor use only protect from elements Safety Instructions 1 Please read and follow these...

Страница 3: ...uld be located within 10 feet of the system Drain must allow a minimum flow of 2 gals min Compliance with most local plumbing codes requires installation of an approved air gap in the drain line The d...

Страница 4: ...ng a proper tube cutter for a clean square cut When routing and securing tubing avoid loops or kinks Membrane Reject Connection Optimized Water Line to Tank Blue 3 8 from Processor To Tank Connection...

Страница 5: ...Blend Valve Assembly 1 4 blue as shown below Step 1 Attach the system with 2 screws user supplied through the attachment keyholes shown below Use anchors or attach directly to studs Be sure to allow a...

Страница 6: ...rom the lower left part of the Permeate Pump Attention Warranty will be void if this step is not performed properly Step 3 Insert and lock the CTO Q10 Cartridge into the Pre Filter Head as shown NOTE...

Страница 7: ...er 164 89905 Step 5a Install the Feedwater Adapter from the installation kit into the user supplied 1 2 Feedwater Supply Valve Do not over tighten Step 5b Connect a piece of 3 8 green tubing to the Fe...

Страница 8: ...ect the other end to the Tank Tee as shown below Step 7b The remaining connection at the Tank Tee is the Optimized Water Outlet Connect a piece of 3 8 blue tubing to the Tank Tee This will later be th...

Страница 9: ...e TDS monitor Step 7c Install TDS Monitor next to the RO processor using sticky tape with Velcro supplied with monitor Connect TDS Probe to 1 4 tee fitting located right before Optimized Water to Stor...

Страница 10: ...alternates between the optimized water line and the drain line You will notice that the water flow pulses when the system is making water Step 9a Ensure Bypass Valve is CLOSED Step 9b Ensure Tank Valv...

Страница 11: ...o desired optimized water TDS Close the Storage Tank valve and run optimized water line to drain temporarily Push the on off button on the water quality monitor It will display the optimized water s T...

Страница 12: ...ake 30 minutes to several hours depending on the tank capacity Step 13 v Quick Tank Fill Open Bypass Simply OPEN the Bypass Valve and un filtered water will flow directly into the storage tank When th...

Страница 13: ...using equipment return the Valve to the CLOSED position DO NOT leave the system in bypass mode for prolonged periods of time IMPORTANT Leaving the system in bypass could cause damage to downstream eq...

Отзывы: