POH / AFM
AQUILA AT01-100A
Section 8
HANDLING & MAINTENANCE
Document Nr.:
Issue:
Supersedes Issue:
Date:
Page:
FM-AT01-1010-101
A.09
A.02 (15.10.2013)
03.03.2021
8 - 2
8.1 INTRODUCTION
Section 8 contains factory recommended procedures for correct ground handling as well as
information regarding care and servicing of the AQUILA AT01. Furthermore, it includes
requirements which must be adhered to during inspection as well as during maintenance and
when modifications and repairs are carried out.
8.2 AIRCRAFT INSPECTION PERIODS
The required inspection items are listed and described in the AQUILA AT01 Maintenance
Manual (Document number MM-AT01-1020-110), the Operation Manual of the ROTAX
®
type
912 engine series and the mt-propeller Operation and Installation Manual.
CAUTION
If the engine is operated extensively on AVGAS 100LL (more than 30 hrs within 100 hrs) the
interval between oil changes shall be reduced to 50 hrs.
8.3 MODIFICATIONS AND REPAIRS
Changes to the aircraft are only permissible with the approval of the EASA or the appropriate
National Aviation Authority to ensure that the airworthiness of the aircraft is not adversely
affected.
All maintenance and repair work must be accomplished in accordance with the instructions
contained in the current issue of the AQUILA AT01 Maintenance Manual.
Prior to major repairs and in situations where the cause of damage to the aircraft is unknown,
the aircraft manufacturer or TC holder should be contacted.