POH / AFM
AQUILA AT01-100A
Section 4
NORMAL PROCEDURES
Document Nr.:
Issue:
Supersedes Issue:
Date:
Page:
FM-AT01-1010-101
A.09
A.08 (25.05.2020)
03.03.2021
4 - 18
4.5.13 Engine Shutdown
1.
Throttle
IDLE
2.
Parking Brake
SET
3.
Flaps switch
LDG
4.
ELT
CHECK (frequency 121.5 MHz)
5.
Avionics
switch
OFF
6.
Ignition Switch
OFF
7.
Electrical equipment
OFF
8.
ALT1 / BAT
switch
OFF
9.
Chocks and tie-downs
AS REQUIRED
4.5.14
Refueling
1.
Engine Shutdown as in Section 4.5.13
2.
Ground the aircraft
CAUTION
During refueling, the aircraft must be grounded (for example at the end of the exhaust pipe.)
3.
Open fuel tank filler cap
4.
Refuel both tanks equally
NOTE
Insert the fuel pump nozzle carefully into the tanks to avoid damage.
5.
Replace the fuel tank filler caps
6.
Remove grounding cable
4.5.15 Flight in Heavy Rain and/or with Wing Contamination
CAUTION
When flying with wet and/or contaminated wings and control surfaces, performance and
handling qualities may be reduced. This applies in particular to take-off distance, climb
performance, cruising speed and stall characteristics.
The stall speed may increase up to 3 kts and the air speed indicator may give false readings.
Visibility may deteriorate considerably in rain.