5. Place the TigerShark in the pool. It will slowly sink to the bottom of the pool as the air 
inside is released. Submersing by hand is helpful.

6. Connect the power supply to the GFCI protected outlet and switch to the “on” position. 
The TigerShark will perform a self-diagnostics routine for several minutes before starting the  
cleaning cycle. 

The QC will go into Quick Clean cycle.

Caution: DO NOT switch power supply ON when the TigerShark is out of water. This may 
result in damage to the pump & drive motor seals, which will VOID the warranty.

7.  The  TigerShark  will  automatically  shut  off  after  a  cleaning  cycle  of  3  hours.  (90  
minutes for Quick Clean, 7 hours for the TigerShark2

®

). If your pool is cleaned in less 

time than 3 hrs, you may shut the TigerShark off manually by switching the power supply 
to the off position.

should a second cleaning cycle be required, switch off the power supply for 10 

seconds and restart.

8. After the pool has been cleaned, switch OFF the power supply before removing the 
TigerShark from the pool.

9. Remove the TigerShark from the water at the shallow end of the pool by pulling the 
cable  until  the  TigerShark  reaches  the  surface.  Then  lift  it  out  of  the  water  using  the 
handle, NOT the cable.

caution:

  When  pulling  the  cable,  reel  it  in  hand-over-hand  - 

do  not

  reel  it  around  

your arm.

neVer enter the swiMMing Pool when the aQua Vac is oPerating.

Optimum operating water temperature range for the TigerShark is 50ºF - 100ºF. 

Remove the TigerShark from the pool after each use. Keeping the TigerShark permanently 
in the pool may result in additional service requirements.

Содержание TigerShark

Страница 1: ...__________________________ Address___________________________________________________________________________________ City________________________________________________State___________Zip____________________ Date Purchased____________________________________________________________________________ Is this replacing another pool vacuum Yes____ No____ If yes what brand ______________________ Purch...

Страница 2: ......

Страница 3: ...Vac Pool Cleaners Inc at its sole option may determine that this warranty will not apply and that reimbursement for such repair will not be made because of failure to comply with such factory specified instructions Filter cartridges are not covered by this warranty and will be replaced only with your prior approval of the charges Any unit that is used outside the continental U S is excluded from t...

Страница 4: ......

Страница 5: ...or www haywardnet com Contents General Information 6 General Operating Instructions 6 TigerShark QC Plus and 2 Plus Operating Instructions 8 Remote Control Trouble Shooting 9 Machine Assembly Parts 10 Maintenance 11 Trouble Shooting 12 Specifications 13 Figures 14 17 Safety Precautions 18 Preventative Maintenance 19 Parts Ordering Instructions 19 All Models TigerShark TigerShark 2 TigerShark Plus ...

Страница 6: ...tely automatic Filter cleaning is much easier with the new patented cartridge type filter element Adaptive Seek Control Logic ASCL Microprocessor control optimizes cleaning routine for each individual pool size and shape Electronic Self Diagnostics and Overload Protection Simple Direct Drive design w non corrosive bearings for high reliability GENERAL OPERATING INSTRUCTIONS Take a moment to get fa...

Страница 7: ...d in less time than 3 hrs you may shut the TigerShark off manually by switching the power supply to the off position Should a second cleaning cycle be required switch OFF the power supply for 10 seconds and restart 8 After the pool has been cleaned switch OFF the power supply before removing the TigerShark from the pool 9 Remove the TigerShark from the water at the shallow end of the pool by pulli...

Страница 8: ... the unit will automatically shut off in 3 hours If the Quick Clean cycle is complete the on off power switch must be turned off and back on and then the Full cycle can be chosen during the Quick Clean cycle TIGERSHARK Plus and tigershark 2 plus OPERATING INSTRUCTIONS 1 For installation setup and general operation information refer to the General Operating Instructions located on page 6 2 For the ...

Страница 9: ...tion The batteries in the remote control may need to be replaced Requires one CR2032 lithium battery The overload protection breaker located on the front of the power supply may be tripped To reset depress the small black button located above the flotation cord connection on the power supply The Turning Foot may be lodged with debris Turn cleaner off and remove from the pool Manually work foot in ...

Страница 10: ...10 55 100 ...

Страница 11: ... perform Periodic Cleaning of Moving Parts WARNING Disconnect the power supply from electrical outlet before cleaning moving parts Inspect the pump outlet to ensure that no debris or hair has clogged the impeller The impeller can be cleaned by removing the impeller tube 9 by twisting rotating it Fig h Remove any debris that has accumulated between the tracks 10 and wheels 11 Storage When out of th...

Страница 12: ...ater and reset the power You may go to TigerShark Owners FAQS at our website for additional information 12 Important Tips Cleaning the filter cartridge after every use maximizes the unit s performance If the TigerShark has trouble climbing the pool walls during the middle of the cleaning cycle clean the filter and resume cleaning Replace worn brushes 12 to ensure maximum cleaning performance To av...

Страница 13: ...ed Service Center Use Filter Type Removable Re Usable Pleated Element Cartridge Media Pleated Cellulose Polyester Blend Cleaning Routine Control Type Adaptive Seek Control Logic ASCL Microprocessor Cleaning Cycle 3 hrs 7 hrs for TigerShark2 Drive System Direct Drive w Polyurethane Drive Track Acetal Stainless Steel Bearing System Power Supply Primary Voltage 110 120 volt AC 220 240 volts for 240 v...

Страница 14: ...14 Figures ...

Страница 15: ...15 Figures cont ...

Страница 16: ...16 Figures cont Mounting Instructions ...

Страница 17: ...easonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will occur in a particular installation If the unit does cause harmful interferenc...

Страница 18: ...L WHILE CLEANER IS IN OPERATION 7 NEVER ALLOW PLUG TO ENTER THE POOL 8 DO NOT OPERATE THE MACHINE OUT OF WATER THIS WILL DAMAGE THE MOTOR SEAL AND VOID THE WARRANTY 9 DO NOT DRAG THE MACHINE OUT OF THE POOLAGAINST THE SIDE WALL THIS COULD DAMAGE UNIT AND OR YOUR POOL WALL 10 SOME POOLS HAVE A CORNER OR A CORNER STEP CONFIGURATION THAT MAY CAUSE THE UNIT TO HANG UP THEREFORE DO NOT LEAVE THE UNIT C...

Страница 19: ...ions contact your local Service Center or call us at 1 800 327 0141 Monday Friday 8 30 a m 5 30 p m EST PARTS ORDERING INSTRUCTIONS Should you desire to order repair parts follow this simple procedure 1 Determine each of the parts you will need and identify them by part number Use this book as a guide be sure to note due to continual product improvement parts may vary depending on the year of manu...

Страница 20: ...d Road West Palm Beach Florida 33409 USA Toll Free 1 800 327 0141 561 688 0211 Fax 561 688 0217 E Mail info aquavacsystems com www aquavacsystems com or www haywardnet com To order parts call 800 949 9892 rev 11 08 ...

Отзывы: