SPECIFICATIONS/DIMENSIONS
Table I – Recommended Circuit Breaker Size for 115V 60 Hz Motors
Pump Model
Motor
Voltage/
Full Load
Circuit Breaker
No.
H.P.
Hz/Phase
Amps
Rating(Amps)
AT230702, AT240702
3/4
115/60/1
9.4
15
AT231002, AT241002
1
115/60/1
13.2
20
AT231502, AT241502
1-1/2
115/60/1
13.5
20
NOTICE: Values given in table above are for pump motor only. Add the amp draw for any addi-
tional accessories installed on pump motor circuit (heater, blower, etc.) to the listed amp ratings
when figuring circuit and circuit breaker requirements.