Multiplex Duo

 

Shower ControlShower Control

IMPORTANT AND SAFETY INFORMATION

Please read these instructions carefully before starting installation and keep in a safe place  
for future reference.

This Installation Guide contains instructions for the correct  
connection of the Duo product. The warranty will be 

 

invalidated if the product is not installed according to these 
instructions. Aquatica accepts no liability for loss or damage  
resulting from installation or use of the product that is not 
in accordance with these instructions.

All Aquatica valves are mixed flow products, which, for  
optimum performance, require hot and cold supplies 
to be reasonably balanced, with no more than 0.5bar 
pressure difference between them.

This product MUST be installed by a competent person in 
accordance with all current relevant state and municipal 
statutes and regulations, including building regulations.

All showers requiring an electrical connection MUST be  
installed by a certified plumber and electrician. Before any 
electrical connections are made, the electricity supply must 
be turned off at the mains switch. All electrical installation 
must be carried out only by a certified electrician.

We recommend that the temperature of the shower hot 
water supply should not exceed 65°C (149F).

The processor is supplied factory pre-set at a maximum 
temperature of 40°C (104F), in line with cUPC standards. 
The maximum temperature is fully adjustable to suit the site 
conditions.

Important: The processor must be installed in an ac-
cessible location for servicing and maintenance (and 
no warranty claim can be considered or liability ac-
cepted by Aquatica if lack of accessibility has pre-
vented maintenance).

The processor must not be installed in situations where 
either the ambient temperature is likely to exceed 40°C 
(104F) or where freezing may occur.

The user controls must not be installed in situations where 
the ambient temperature is likely to fall below 5°C(41F) or 
rise above 70°C. (158F).

The minimum depth of w’)all required to fit the control fixing 
brackets is 70mm (2 3/4”). 35mm (1.4”) depth is required if 
the rear of the bracket is cut down.

Cables mounted on surfaces must be protected by a suit-
able approved conduit. This applies even in a loft, where 
there may be a risk of damage by vermin.

Cables that are chased into walls must also be 

 

protected by a conduit or sheathing to allow removal 
for service and maintenance.

The power lead must not be replaced by anyone other than 
the manufacturer or its accredited agent.

The user control operates from a low voltage source.

Please check for hidden pipes or cables before drilling  
any holes.

The Multiplex Duo is suitable for domestic or commercial 
use. This product is supplied with a 5 year guarantee.

This product is not intended for use by children or persons 
with reduced physical or mental capabilities, and should 
not be used by such persons without appropriate instruc-
tion and supervision.

WARNING

CONTINUOUSLY TURNING THE CONTROL WHEEL IN 
THE CLOCKWISE DIRECTION MAY OVERRIDE THE 
PRE-SET MAXIMUM TEMPERATURE, RESULTING IN 
A RISK OF SCALDING.

ALWAYS TAKE CARE WHEN OPERATING THE 

 

CONTROL WHEEL, AND DO NOT LEAVE CHIL-
DREN UNATTENDED WHILST THE PRODUCT IS IN  
OPERATION.

Pipe sizing

To reduce pressure losses and help maintain flow rate, 3/4” 
pipework should be used on the inlets and reduced to 1/2” 
as close to the processor as possible, and elbows should 
be kept to a minimum.

Pipe runs on both inlet and outlet should be as short as 
possible to avoid reduction of flow rate at the shower head. 
If 1/2” pipe must be used, or long pipe runs are unavoida-
ble on the outlet, copper pipe should be used rather than 
plastic, particularly if a diverter is fitted.

All copper pipework must be cross-bonded and connected 
to an earthing point.

Full bore isolation valves must be fitted for maintenance 
purposes.

Flushing

After completing soldering the pipework should be thor-
oughly flushed out in accordance with the state and munic-
ipal regulations prior to connection of the product.

After installation

We recommend that the shower is not used for 24 hours 
after first being installed to allow the back up battery to 
become fully charged before use.Please familiarise the end 
user with how the Multiplex Duo works.

Aquaticausa.com  
Aquaticabath.ca
E:
 [email protected] 

Содержание Multiplex Duo

Страница 1: ...Function Form Fashion Aquaticausa com Aquaticabath ca E info aquaticabath com Multiplex Duo Shower Control Installation Care Manual INTERNATIONAL Function Form Fashion Function Form Fashion ...

Страница 2: ...is 70mm 2 3 4 35mm 1 4 depth is required if the rear of the bracket is cut down Cables mounted on surfaces must be protected by a suit able approved conduit This applies even in a loft where there may be a risk of damage by vermin Cables that are chased into walls must also be protected by a conduit or sheathing to allow removal for service and maintenance The power lead must not be replaced by an...

Страница 3: ...E CONTROL CONTROL FIXINGS CONTROL FIXING BRACKETS DUO FLOW OUTLET CONTROL ADAPTOR RING SETS BACK PLATES FOAM GASKETS DUO TEMPERATURE CONTROL DUO FLOW OUTLET CONTROL INLET OUTLET CONNECTORS BACK UP BATTERY SUPPLY PROCESSOR FIXINGS PROCESSOR DUAL OUTLET SHOWER MDUOSH BATH MDUOBATH TOOLS REQUIRED PENCIL CROSSHEAD SCREWDRIVER 8MM DRILL BIT ADJUSTABLE SPANNER DRILL ...

Страница 4: ...nding on Dynamic water pressure of supply system to the processor All products marked LP Low pressure and MP Medium pressure are also suitable for HP High pressure systems Please note This product must work from a minimum water pressure of 05 bar and above Water pressure recommended MP minimum 0 5 bar HP1 minimum 1 bar HP2 minimum 2 bar HP3 minimum 3 bar HP4 minimum 4 bar Aquaticausa com Aquaticab...

Страница 5: ...r cable must be secured and chased into the wall this must not be left exposed as in the event of a possible leak the cable will be protected Please make sure the cable is installed by a qualified electrician and has certificates to back this up Important The Processor must have an access panel Note The controller can be fitted anywhere in the showering area Cable length 6m max Bath filler Handset...

Страница 6: ...UO CEILING MOUNTED INSTALLATION SCENARIO handshower and fixed overhead shower configuration Handset fixed head outlets Cable length 6m max Note The controller can be fitted anywhere in the showering area MULTIPLEX DUO BATH SHOWER CEILING MOUNTED INSTALLATION SCENARIO handshower and bath filler Cable length 6m max Extension cables for the Bath filler control are available Bath Filler Handset oiutle...

Страница 7: ...nance Note If a double trim plate is used the control fixing brackets must be positioned so that the openings at the back are horizontal as shown Attach the control fixing brackets using the screws supplied Brackets attached from behind Function Form Fashion 1 Multiplex Duo Shower ControlShower Control INSTALLATION SEQUENCE Shower Control Option To make the installation easier we recommend that th...

Страница 8: ...h the wall Carefully cut down the bracket collars as marked Note Feeding a string or wire through the brackets and conduit will make it easier to pull the cables through to the processor Without optional trim plate String or wire Position the adaptor rings inside the back plate foam gaskets and fix through the adaptor ring holes into the bracket collars using the 15mm screws supplied Back plate Ad...

Страница 9: ...d turn clockwise to lock in position Push fit the front control wheels onto the controls Now follow step 16 on page 11 Carefully pull the front control wheel off the controls taking care not to mix them up Feed the foam seals onto the data cables and onto the control bodies Feed the control data cables through the brackets Note The Multiplex Duo Temperature control should be in the top position an...

Страница 10: ...om the control brackets by pulling off the front control wheel turning the control bodies anti clockwise and liffting out To refit position the control bodies in the slots and turn clockwise 12 13 14 15 Bath control option O ring Prepare the bath rim to take the control fixing brackets 35mm diameter holes are required to fit the brackets Feed the control data cables through the holes then insert t...

Страница 11: ...essor 16 15VB attery WLAN ValveC ontrollerD ual Wheel Inside Processor Dual outlet Connector block Fixing Holes Cover retaining holes Note Outlet 1 is the default outlet when turned on water will flow through this outlet first If a bath filler option is required it must be connected to outlet 1 Battery compartment Power supply Hot Cold Inlets Outlets ...

Страница 12: ... inlet connectors into the inlet valves one long and one short connector Note If required the nut ends of the inlet connectors and outlet connectors can be cut off and compression fittings can be used to attach the pipework 17 18 19 20 Connecting the processor Fix the processor in position using the fixings supplied Remove the inlet connectors retaining bolt 15VB attery WLAN ValveC ontrollerD ual ...

Страница 13: ...tors into the outlet valves Note Outlet 1 is the default outlet when turned on water will flow through this outlet first If a bath filler option is required it must be connected to outlet 1 21 22 23 24 Connecting the processor Important Flush through the pipework before connection Attach the 15mm hot and cold water supply connections Remove the outlet connectors retaining bolt 15VB attery WLAN Val...

Страница 14: ...at Note Make sure that the pipework is perpendicular to the processor so that there is no strain on the fittings use pipe clips as required Run a pipe from the mixed water outlet on the processor through the wall to the proposed position of the shower hose outlet etc Connect the data cable from the temperature control to the Controller connection in the processor Re insert the outlet connectors re...

Страница 15: ...w outlet control to the Dual Wheel connection in the processor 28 29 Connect flow outlet control data cable Connect the battery cable to the Battery for battery back up connection and place the battery in the compartment 15V Battery WLAN Valve Controller Dual Wheel Display WLAN ValveC ontrollerD ual Wheel Display 15V Battery WLAN Valve Controller Dual Wheel Display 15VB attery ...

Страница 16: ...ass and will invalidate your guarantee WARRANTY Aquatica Multiplex series digital shower and bath controllers carry a 5 year warranty that covers all manufacturing defects This warranty does not cover damage caused during fitting damage resulting from incorrect installation or damage caused by misuse or inappropriate cleaning Please do not disassemble the processor unit as this will invalidate you...

Страница 17: ...Function Form Fashion MultiplexTrio Shower Control Function Form Fashion Ø8 x 55 Ø8 x 55 this side up this side up 235mm 9 2inch Note Diagram is to scale Ensure when printing that image size is at 100 ...

Страница 18: ...Aquaticausa com Aquaticabath ca E info aquaticabath com Multiplex Duo Shower ControlShower Control ...

Страница 19: ...Function Form Fashion Function Form Fashion ...

Страница 20: ...Aquaticausa com Aquaticabath ca E info aquaticabath com Function Form Fashion Function Form Fashion ...

Отзывы: