SAFETY ITEM:  It is imperative that the top mounting bolt extend through both cylinder walls 
and through the square key tube. The lift may malfunction if the square key is not properly 
engaged and injury could result.

Place turning handle in position and reinsert the 1/2” bolt through all three components. Place 

locknut on end of bolt and tighten to snug.

WATER CONNECTION

 

Connect the water hose to the valve 

and turn on the water supply.   Do 

not leave the water turned on when 

the lift is not in frequent use.

Your IGMT  pool lift operates using 

normal household water pressures of 

55-65 PSI.   No electricity is used.  

With sufficient water pressure and 

proper installation, the IGMT will 

lift a 300 lb. individual.  If your 

water pressure exceeds 70 PSI, 

a reducer is necessary to prevent 

damage to the lift.  Although 55-65 

PSI is required to lift the rated load, 

less weight can be lifted wiht lower 

pressures.

In low pressure situations, a pump can be added to  boost pressure.   If a pump is used, do not 

use water from the swimming pool to power the lift.   Chemicals from the pool water may 

damage the internal components of the lift.   Follow the pump manufacturer’s instructions and 

consult local building codes if you are installing a pump that exceeds 45 PSI.   

Never allow the 

pump’s pressure to exceed 70 PSI.  Excessive pressure can damage the lift. 

Some customers prefer to install a recessed water connection specifically for the lift.  Place water 

connection so that it doesn’t interfere with the user’s feet on rotation. 

ATTACH  SEAT

Turn the water on. Operate the control so that the seat tube/piston rod contracts into the cylinder. 

Check for any leaks.  If necessary, tighten valve.  Rotate the seat to a position over the deck and 
attach the seat with provided bolt.  Secure with a lock nut and tighten snug.

4

Содержание IGMT

Страница 1: ...Aquatic Access Inc Pool Lift Model IGMT Installation Guide Instruction Manual AquaticAccess com 1921 Production Drive Louisville Kentucky 40299 2110 USA 800 325 5438 502 425 5817 Fax 502 425 9607...

Страница 2: ......

Страница 3: ...Decks Alternative Installations Assembly of Lift Water Connection Attach Seat Operation of Lift Service and Maintenance Routine Inspection Disassembly of Lift Determining the Cause of a Leak Cleaning...

Страница 4: ......

Страница 5: ...tion for the lift Using a 4 carbide core drill provided by the customer drill a hole in the concrete decking and clear to a depth of 8 Fill the hole around the socket with a good grade of hydraulic ce...

Страница 6: ...socket plate above and insert bolts Place washers and nuts on bolt and tighten securely For installations where there is a concrete deck with a void beneath 1 2 anchor bolts are used to secure the anc...

Страница 7: ...bly any accessories Carton 3 The mast is contained in the third package After you have installed the socket and allowed the cement to cure overnight insert the mast into the socket and check that it r...

Страница 8: ...t Although 55 65 PSI is required to lift the rated load less weight can be lifted wiht lower pressures In low pressure situations a pump can be added to boost pressure If a pump is used do not use wat...

Страница 9: ...le aligned with the T handle lock in the desired stationary position Once the person is seated rotate the seat until it is over the water and lower the seat slowly by opening the valve a little at a t...

Страница 10: ...end the piston rod completely This will expel most of the water from inside cylinder 4 Pull the piston rod back into cylinder by hand Rotate the cylinder back over the deck and let the piston rod rest...

Страница 11: ...hrough the top of the cylinder 9 Place the piston rod assembly on a CLEAN surface as dirt and debris will adversely affect the lift s performance Handle the piston rod carefully Any scratches on the p...

Страница 12: ...ll or simply by age or wear Replacement seals are always available from Aquatic Access CLEANING OF THE INSIDE OF THE CYLINDER To clean the inside of the cylinder spray the inside with an all purpose c...

Страница 13: ...g threads 9 Once the piston rod assembly is installed rotate it so the seat bracket holes at the bot tom of the piston are parallel to the 1 2 top mounting bolt holes at the top of the cylinder 10 Sli...

Страница 14: ...quaticAccess com Remember to send in your warranty card to Aquatic Access 1921 Production Drive Louisville KY 40299 2110 If it becomes necessary to replace any part in your unit we need to know its se...

Страница 15: ...is to be left unused for eight hours or longer Always run the seat up and down through several cycles after turning the water supply on This bleeds air out of the cylinder which could cause unexpected...

Страница 16: ...g on or around the lift 6 Do not jump or dive from lift 7 Turn water supply OFF and secure lift with push pin when the lift is to be left unused for eight hours or longer 8 Always run the seat up and...

Страница 17: ...er squirts out of top of cylinder Large amounts of water are getting past the seal Often this corrects itself If not clean or replace the seal White grey or brown chalky deposits on out side surfaces...

Страница 18: ...Rotation Manual 360 Materials 304L and 316L stainless steel brass UHMW plastic rubber Overall Size Height 84 213 cm Range of motion Lift provides 42 107 cm vertical travel Portability Lift can be rem...

Отзывы: