Aquatic Access IGMT Скачать руководство пользователя страница 16

AQUATIC ACCESS 

POOL LIFT MODEL #

Serial # 

US Patent Number

UP

DOWN

STOP

MAXIMUM WEIGHT CAPACITY
VARIABLE  AT 55/65 PSI/ 3.8-4.5 BAR

WATER PRESSURE NOT TO EXCEED  70 PSI/4.8 BAR 
OR DAMAGE TO LIFT WILL RESULT. USE A REDUCER
BETWEEN WATER SOURCE AND LIFT IF NECESSARY.

BEFORE USE BY A SWIMMER

INSTRUCTIONS FOR USE

TO REMOVE POOL LIFT

IMPORTANT SAFETY WARNINGS

1921 Production Drive    Louisville, KY    40299-2110   USA

 

800.325.5438 (LIFT)

 

502.425.5817

 

AquaticAccess.com

1. Turn control knob to UP to raise seat, which will 
     automatically turn 180° over deck.
2. Insert safety pull-pin before loading or unloading
     to prevent accidental descent.
3. Seat the swimmer, fasten seat belt, and place feet on 
     footrest. Swimmer’s feet must be on footrest or injury
     may result.
4. Remove pull-pin and turn control knob to DOWN 
     to lower  the swimmer into the water. Seat turns
     automatically at top of travel.
5.  Reverse procedure to lift swimmer.

   

When lift is not to be in use for 8 hours or longer, turn
off water and let seat descend, or place seat in raised 
position and insert pull-pin to hold it there. Then turn
off the water and turn the control knob to the DOWN
position. When ready to use lift again, turn on water 
and purge air from the cylinder and specified above 
(#4 in Before Use by a Swimmer).

NOTE: Speed of seat travel and turn can be controlled 
by turning control knob to less than full up or down            
position.  If water pressure is very high, seat may
move too quickly. Experiment to find the  best settings 
for your water pressure.

1.  Remove seat and lower lift to full down position.
2.  Turn off water at source and disconnect supply hose.
3. Lift out of socket and roll on wheel. 

1.    Never allow more than one person on the lift at a 
        time.
2.    Keep fi ngers, towels and loose clothing away from
        moving parts.
3.    Do not hang towels or robes on lift at any time.
4.    Do not allow people to climb on or hang from lift.
5.    Do not allow playing or rough–housing on or around 
         the lift.
6.    Do not jump or dive from lift.
7.    Turn water supply OFF and secure lift with push pin 
        when the lift is to be left unused for eight hours or  
        longer.
8.   Always run the seat up and down through several 
       cycles after turning the water supply on. This bleeds 
        air out of the cylinder which could cause unexpected 
        movement.
9.    Be certain swimmer is settled in the seat before 
        operating lift.
10.  Always place swimmer’s feet on the footrest.
11.  Never allow seat occupant’s mouth to submerge 
        beneath the water.
12.  Do not exceed weight and pressure limits.
13.  Do not use lift during an electrical storm or high 
         wind.
14.   Always drain water from cylinder before exposing 
          lift to temperatures below freezing.
15.   Never use any sort of oil or petroleum-based 
         product on the inside of the lift. It will damage the
         piston

.

DO NOT STORE LIFT IN BELOW-FREEZING ENVIRONMENTS.

1.  In seat-down position, mount lift into deck socket.
2.  Turn control know to down position.
3.  Connect supply hose and turn on water.
4.  With water supply on, operate Pool Lift control knob 
       to move seat several short strokes up and completely
       down.  This will purge air from the system.  If the seat
       does not move in a smooth  motion, repeat this step 
       until it does.  Air trapped inside must be removed for
       safe operation.

REV. 10/6/10

INST

R

UCTIONS FOR 

Y

OUR P

AR

TICUL

AR LIFT

WILL BE FOUND IN 

THIS AREA OF  

THE L

ABEL

FOUND ON 

THE CYLINDER OF 

Y

OUR LIFT

SERIAL NUMBER

MODEL NUMBER

WEIGHT CAPACITY

This illustration is of a generic Aquatic 
Access label and is here only to provide 
location of pertinent numbers found on 
every Aquatic Access label.

Please refer to the label attached to 
your lift for important information and 
instructions for your Aquatic Access lift.

You will fi nd a label similar in style 
to this one on every Aquatic Access 
lift cylinder.

Please do not remove that label 
from your lift. You will need the 
serial number should you ever 
require replacement parts for your 
lift.

The label on the lift cylinder also 
contains instructions for use and 
safety proceduress.

Sample Label to Indicate Location of Numbers Only

Rev. 10/6/10

12

Содержание IGMT

Страница 1: ...Aquatic Access Inc Pool Lift Model IGMT Installation Guide Instruction Manual AquaticAccess com 1921 Production Drive Louisville Kentucky 40299 2110 USA 800 325 5438 502 425 5817 Fax 502 425 9607...

Страница 2: ......

Страница 3: ...Decks Alternative Installations Assembly of Lift Water Connection Attach Seat Operation of Lift Service and Maintenance Routine Inspection Disassembly of Lift Determining the Cause of a Leak Cleaning...

Страница 4: ......

Страница 5: ...tion for the lift Using a 4 carbide core drill provided by the customer drill a hole in the concrete decking and clear to a depth of 8 Fill the hole around the socket with a good grade of hydraulic ce...

Страница 6: ...socket plate above and insert bolts Place washers and nuts on bolt and tighten securely For installations where there is a concrete deck with a void beneath 1 2 anchor bolts are used to secure the anc...

Страница 7: ...bly any accessories Carton 3 The mast is contained in the third package After you have installed the socket and allowed the cement to cure overnight insert the mast into the socket and check that it r...

Страница 8: ...t Although 55 65 PSI is required to lift the rated load less weight can be lifted wiht lower pressures In low pressure situations a pump can be added to boost pressure If a pump is used do not use wat...

Страница 9: ...le aligned with the T handle lock in the desired stationary position Once the person is seated rotate the seat until it is over the water and lower the seat slowly by opening the valve a little at a t...

Страница 10: ...end the piston rod completely This will expel most of the water from inside cylinder 4 Pull the piston rod back into cylinder by hand Rotate the cylinder back over the deck and let the piston rod rest...

Страница 11: ...hrough the top of the cylinder 9 Place the piston rod assembly on a CLEAN surface as dirt and debris will adversely affect the lift s performance Handle the piston rod carefully Any scratches on the p...

Страница 12: ...ll or simply by age or wear Replacement seals are always available from Aquatic Access CLEANING OF THE INSIDE OF THE CYLINDER To clean the inside of the cylinder spray the inside with an all purpose c...

Страница 13: ...g threads 9 Once the piston rod assembly is installed rotate it so the seat bracket holes at the bot tom of the piston are parallel to the 1 2 top mounting bolt holes at the top of the cylinder 10 Sli...

Страница 14: ...quaticAccess com Remember to send in your warranty card to Aquatic Access 1921 Production Drive Louisville KY 40299 2110 If it becomes necessary to replace any part in your unit we need to know its se...

Страница 15: ...is to be left unused for eight hours or longer Always run the seat up and down through several cycles after turning the water supply on This bleeds air out of the cylinder which could cause unexpected...

Страница 16: ...g on or around the lift 6 Do not jump or dive from lift 7 Turn water supply OFF and secure lift with push pin when the lift is to be left unused for eight hours or longer 8 Always run the seat up and...

Страница 17: ...er squirts out of top of cylinder Large amounts of water are getting past the seal Often this corrects itself If not clean or replace the seal White grey or brown chalky deposits on out side surfaces...

Страница 18: ...Rotation Manual 360 Materials 304L and 316L stainless steel brass UHMW plastic rubber Overall Size Height 84 213 cm Range of motion Lift provides 42 107 cm vertical travel Portability Lift can be rem...

Отзывы: