RISKS TO AVOID

   

DANGER: RISK OF INJURY

•  DO NOT sit in the filter compartment area. Sitting in this area can cause:       

a) Restriction of Filter Pump suction/vacuum        b) Damage to components

•  Both can result in bodily harm. Should damage occur to components in this area, replace 

immediately!

To reduce the risk of injury to persons, DO NOT remove floating weir, basket, and filter located in 

the filter compartment while the spa is running.

•  The suction fittings in the spa are sized to match the specific water flow created by the pump. Never 

replace a suction fitting with one rated less than the flow rate marked on the original suction fitting.

•  There is a danger of slipping and falling. Remember that wet surfaces can be very slippery. Take 

care when entering or exiting the spa.

•  Never operate spa if the suction fittings are broken or missing.

•  The device should not be used by persons (including children) with reduced physical, sensory or 

mental capabilities, or lack of experience and knowledge, unless they receive supervision or training.

•  People with infectious diseases should not use the spa.

•  Keep any loose articles of clothing or hanging jewelry away from rotating jets or other moving 

components. 

Increased side effects of medication

•  The use of drugs, alcohol or medication before or during spa use may lead to unconsciousness with 

the possibility of drowning.

•  Persons using medications should consult a physician before using a spa; some medication may cause 

a user to become drowsy, while other medication may affect heart rate, blood pressure, and circulation.

•  Persons taking medications which induce drowsiness, such as tranquilizers, antihistamines or 

anticoagulants should not use the spa.

Health problems affected by spa use

•  Pregnant women should consult a physician before using spa.

•  Persons suffering from obesity or with a medical history of heart disease, low or high blood pressure, 

circulatory system problems, or diabetes should consult a physician before using spa. 

Unclean water

•  Keep the water clean and sanitized with correct chemical care. The recommended levels for your 

spa are:   Free Available Chlorine (FAC): 

3.0-5.0 ppm  Total Alkalinity:  

40 - 120 ppm   

   

      Water pH:  

 

 

7.2 - 7.8 

Calcium Hardness:  50- 150 ppm

IMPORTANT: 

Turn jet pump on for at least ten minutes after adding ANY spa water 

chemicals into the filter compartment.

•  Clean the filter cartridge monthly to remove debris and mineral buildup which may affect the 

performance of the hydromassage jets, limit the flow, or trip the high-limit thermostat which will turn 

off the entire spa.

AVOIDING THE RISK OF HYPERTHERMIA

Prolonged immersion in hot water can result in HYPERTHERMIA, a dangerous condition which occurs 

when the internal temperature of the body reaches a level above normal (98.6°F, 37ºC). The symptoms 

of hyperthermia include unawareness of impending hazard, failure to perceive heat, failure to recognize 

the need to exit the spa, physical inability to exit the spa, fetal damage in pregnant women, and 

unconsciousness resulting in a danger of drowning. 

Содержание Fairfax

Страница 1: ...OWNER S MANUAL 230V 60Hz Model...

Страница 2: ...person 84 84 36 818 LBS 330 230V Fairfax NL 6 person 84 84 36 818 LBS 330 230V Ventura 6 person 89 89 36 918 LBS 380 230V CAUTION DO NOT OPERATE SPA BEFORE READING THIS MANUAL Failure to read this man...

Страница 3: ...26 C 40 C 10 JETS OPERATION 11 MULTI COLOR LED LIGHT 11 ON OFF 11 PROGRAM 12 DIAGNOSTIC LCD MESSAGE 13 COMPONENT OPERATION SPA COMPONENT OPERATION 14 MUSIC 14 FILL UP AND START UP INSTRUCTIONS FILLING...

Страница 4: ...mfortable Children are especially sensitive to hot water Remind children that wet surfaces can be very slippery Make sure that the children are careful when entering or exiting the spa DON T Allow chi...

Страница 5: ...nction and the possibility of an electric shock Disconnect the power until the fault has been identified and corrected IMPORTANT Failure to wait 30 seconds before resetting the GFCI may cause the spa...

Страница 6: ...a physician before using a spa some medication may cause a user to become drowsy while other medication may affect heart rate blood pressure and circulation Persons taking medications which induce dr...

Страница 7: ...roduct Listing should be permanently installed where it is visible to the users of the spa IMPORTANT SPA INSTRUCTIONS The following contains important spa information and we strongly encourage you to...

Страница 8: ...nt A warmer climate may require shade from the hot sun Consider placement of trees shrubs patio cover or perhaps a gazebo structure to provide what you will need Indoor installations require adequate...

Страница 9: ...ldew or other problems Check for airborne moisture s effects on exposed wood paper etc in the room To minimize these effects it is best to provide plenty of ventilation to the spa area An architect ca...

Страница 10: ...e equipment compartment Remove all the screws around the top bottom and sides of the large full panel door Lower door panel slightly pull bottom of door away from spa then remove Equipment Compartment...

Страница 11: ...rounded supply conductors to comply with Section 422 20 of the National Electric Code ANSI NFPA 70 The disconnecting means must be readily accessible to the spa s occupant but installed at least 5 fee...

Страница 12: ...breaker The circuit must be dedicated and should not be shared with any other appliances The power supply must be hard wired into the power pack White Neutral Wire that is connected to Spa Neutral goe...

Страница 13: ...pressed again the set temperature will increase or decrease depending on which button is pressed After five seconds the LCD will automatically display the current spa temperature CONTROL PANEL OPERATI...

Страница 14: ...abrupt color changes slow full color wheel and fast full color wheel NOTE If left on the light will automatically turn off after 4 hours of operation MODE CLEANUP MODE Press the Mode button to start t...

Страница 15: ...tinue pressing the Light button until the actual temperature is displayed Powering down of the spa will also reset the first filter start time FILTER CYCLE SUSPENSION The filter cycle will be suspende...

Страница 16: ...error clears Prr A problem is detected with the temperature probe Call Customer Service OH The water temperature in the spa has reached 108 F 42 C Do not enter the water Remove the spa cover and allow...

Страница 17: ...ing the faces of the hydrotherapy jets to close the ones that are not in use HYDROTHERAPY JETS The hydrotherapy jets are recessed in the wall of the spa Rotate the large or medium jet faces to turn th...

Страница 18: ...g in air causing the pump to cavitate you need to add water 6 Check the filter installation and make sure the filter is not loose APPLYING POWER 1 Turn power to spa ON after filling spa from the main...

Страница 19: ...safe range of total alkalinity is established proceed to the next step STEP 3 DETERMINE CALCIUM HARDNESS It is important to bring the calcium reading to between 50 150 PPM If the reading requires adj...

Страница 20: ...pull up the filter cartridge and bring it out of the spa 4 Always clean the filter using a filter degreaser to remove mineral and oil build up Soak the filter in the degreaser according to the package...

Страница 21: ...en adding chemicals to your spa This will extend the life of your cover The gasses from burned off chemicals will be trapped under the cover if not removed These gasses may erode the protective lining...

Страница 22: ...e lines might freeze and damage the lines and jets a It will be necessary to remove all water from the interior plumbing b Remove the floating weir basket and filter cartridge Clean the filter cartrid...

Страница 23: ...n one direction to increased jet action 3 Make sure the water level is half way between top of spa and top of the gray filter ring 4 Check for dirty filter Clean if necessary 5 Make sure all jets are...

Страница 24: ...21 304275 17 E 5 17...

Отзывы: