AquaTerra Fairfax Скачать руководство пользователя страница 14

11

CONTROL PANEL OPERATION

The “heater” indicator 

 

lights up when the heater is on. It flashes when there is a request for 

more heat, but the heater is not on. Once set temperature is reached the indicator shuts off and 

the low speed of the jet pump turns off after 30 seconds (if not in filter cycle).

JETS OPERATION

Jet Pump 1 button:

•  Press Jets 1 button once to turn Jet Pump 1 on low speed.
•  Press Jets 1 button a second time to turn Jet pump1 on high speed.
•  Press Jets 1 button a third time to shut Jet Pump1 off.

Jet Pump 2 button:

•  Press Jets 2 button once to turn Jet Pump 2 On.
•  Press Jets 2 button a second time to shut Jet Pump 2 Off.

MULTI COLOR LED LIGHT

Press the 

Light

 button once to turn on the lights, press the button again to turn 

the lights off, when turning back on after several seconds the same light mode 

will appear. Every time the light is quickly turned off and on a new light mode 

will appear. The sequence is as follows: White, Aqua, Magenta, Azure, Amber, 

Emerald, Ruby, color wheel with abrupt color changes, slow full color wheel 

and fast full color wheel.

NOTE: 

If left on, the light will automatically turn off after 4 hours of operation. 

MODE

CLEANUP MODE

Press the Mode button to start the cleanup cycle for one minute. The display 

will show CLn” message. This mode forces a purge step of the programmed 

filter cycle and is useful when the user wishes to cleanup the spa water after 

use without waiting for the next filter cycle purge. When active, the display will 

toggle between CLn and water temperature.

SOAK MODE

Press and hold the Mode button for 5+ seconds until SbY is displayed. The 

soak mode clears all pending user demands as well as filtration and smart 

winter mode. The only automatic feature that remains functional is the water 

temperature regulation.

OFF MODE

Press and hold the Mode button for 8+ seconds until OFF is displayed. This function is useful to 

preform simple spa maintenance. When enabled the display will toggle between OFF and water 

temperature. This function will clear all pending user demands for 60 minutes. This mode will be 

cancelled if the user starts a pump.

NOTE:

 If the spa is calling for heat it will take 1 minute before the jet pump will shut off.

Содержание Fairfax

Страница 1: ...OWNER S MANUAL 230V 60Hz Model...

Страница 2: ...person 84 84 36 818 LBS 330 230V Fairfax NL 6 person 84 84 36 818 LBS 330 230V Ventura 6 person 89 89 36 918 LBS 380 230V CAUTION DO NOT OPERATE SPA BEFORE READING THIS MANUAL Failure to read this man...

Страница 3: ...26 C 40 C 10 JETS OPERATION 11 MULTI COLOR LED LIGHT 11 ON OFF 11 PROGRAM 12 DIAGNOSTIC LCD MESSAGE 13 COMPONENT OPERATION SPA COMPONENT OPERATION 14 MUSIC 14 FILL UP AND START UP INSTRUCTIONS FILLING...

Страница 4: ...mfortable Children are especially sensitive to hot water Remind children that wet surfaces can be very slippery Make sure that the children are careful when entering or exiting the spa DON T Allow chi...

Страница 5: ...nction and the possibility of an electric shock Disconnect the power until the fault has been identified and corrected IMPORTANT Failure to wait 30 seconds before resetting the GFCI may cause the spa...

Страница 6: ...a physician before using a spa some medication may cause a user to become drowsy while other medication may affect heart rate blood pressure and circulation Persons taking medications which induce dr...

Страница 7: ...roduct Listing should be permanently installed where it is visible to the users of the spa IMPORTANT SPA INSTRUCTIONS The following contains important spa information and we strongly encourage you to...

Страница 8: ...nt A warmer climate may require shade from the hot sun Consider placement of trees shrubs patio cover or perhaps a gazebo structure to provide what you will need Indoor installations require adequate...

Страница 9: ...ldew or other problems Check for airborne moisture s effects on exposed wood paper etc in the room To minimize these effects it is best to provide plenty of ventilation to the spa area An architect ca...

Страница 10: ...e equipment compartment Remove all the screws around the top bottom and sides of the large full panel door Lower door panel slightly pull bottom of door away from spa then remove Equipment Compartment...

Страница 11: ...rounded supply conductors to comply with Section 422 20 of the National Electric Code ANSI NFPA 70 The disconnecting means must be readily accessible to the spa s occupant but installed at least 5 fee...

Страница 12: ...breaker The circuit must be dedicated and should not be shared with any other appliances The power supply must be hard wired into the power pack White Neutral Wire that is connected to Spa Neutral goe...

Страница 13: ...pressed again the set temperature will increase or decrease depending on which button is pressed After five seconds the LCD will automatically display the current spa temperature CONTROL PANEL OPERATI...

Страница 14: ...abrupt color changes slow full color wheel and fast full color wheel NOTE If left on the light will automatically turn off after 4 hours of operation MODE CLEANUP MODE Press the Mode button to start t...

Страница 15: ...tinue pressing the Light button until the actual temperature is displayed Powering down of the spa will also reset the first filter start time FILTER CYCLE SUSPENSION The filter cycle will be suspende...

Страница 16: ...error clears Prr A problem is detected with the temperature probe Call Customer Service OH The water temperature in the spa has reached 108 F 42 C Do not enter the water Remove the spa cover and allow...

Страница 17: ...ing the faces of the hydrotherapy jets to close the ones that are not in use HYDROTHERAPY JETS The hydrotherapy jets are recessed in the wall of the spa Rotate the large or medium jet faces to turn th...

Страница 18: ...g in air causing the pump to cavitate you need to add water 6 Check the filter installation and make sure the filter is not loose APPLYING POWER 1 Turn power to spa ON after filling spa from the main...

Страница 19: ...safe range of total alkalinity is established proceed to the next step STEP 3 DETERMINE CALCIUM HARDNESS It is important to bring the calcium reading to between 50 150 PPM If the reading requires adj...

Страница 20: ...pull up the filter cartridge and bring it out of the spa 4 Always clean the filter using a filter degreaser to remove mineral and oil build up Soak the filter in the degreaser according to the package...

Страница 21: ...en adding chemicals to your spa This will extend the life of your cover The gasses from burned off chemicals will be trapped under the cover if not removed These gasses may erode the protective lining...

Страница 22: ...e lines might freeze and damage the lines and jets a It will be necessary to remove all water from the interior plumbing b Remove the floating weir basket and filter cartridge Clean the filter cartrid...

Страница 23: ...n one direction to increased jet action 3 Make sure the water level is half way between top of spa and top of the gray filter ring 4 Check for dirty filter Clean if necessary 5 Make sure all jets are...

Страница 24: ...21 304275 17 E 5 17...

Отзывы: