background image

ULTIMATE OZONE™

OZONE GENERATION SYSTEM

MODELS U1000 and U3000 Kit

INSTALLATION AND USER'S GUIDE

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS

SAVE THESE INSTRUCTIONS

Содержание Ultimate Ozone U3000 Kit

Страница 1: ...ULTIMATE OZONE OZONE GENERATION SYSTEM MODELS U1000 and U3000 Kit INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS ...

Страница 2: ...LATION AND OPERATION The installation operation and servicing of this ozone system can only be carried out after reading and understanding the information contained in this guide The installation must be performed in accordance with all federal state and local regulations and codes This product must be wired in conjunction with a properly grounded Ground Fault Circuit Interrupter GFCI Only three 3...

Страница 3: ...1000 Corona Discharge Pump 1 unit OZG4017 Ozone Diffuser Stone 1 unit OZG4016 Ozone Compatible 1 4 Tubing 100 ft Limited Warranty Aquastar Pool Products Inc offers a one year limited warranty on the Ultimate Ozone See warranty sec tion for details and limitations SECTION 2 Installation Location Ultimate Ozone units are designed for wall mounting Mount the unit in a clean protected area either indo...

Страница 4: ...2 3 Remove the bubble plate by unscrewing the two screws located on either side from inside the skimmer s throat and feed the ozone com patible tubing from the junction box to the skimmer Connect 2 PVC pipe to the 2 socket located on the bottom of the throat of the FlowStar skimmer the PVC pipe must be at least 2 4 below water line and no greater than 4 feet See Figure 2 3 BLOW OUT OZONE TUBE TO C...

Страница 5: ...eed 8 0 ppm As Br2 when bathers are present 4 Ultimate Ozone Installation and User s Guide Maintenance The Ultimate Ozone requires little maintenance For a properly prerforming system ensure that the skimmer basket is regulary checked and kept clean from excess debris Every month all visual components should be inspected If anything is found to be damaged it should be replaced SECTION 4 Troublesho...

Страница 6: ...rts thereof to or from AquaStar Pool Products Inc s Technical Service Department Also AquaStar Pool Products Inc is not liable for any loss of time inconvenience incidental expenses such as telephone calls labor or material charges incurred in connection with the removal or replacement of the equipment or any other incidental or consequential damages including but not limited to damage to pool equ...

Отзывы: