  Residual Risk 

6

 

6.1  Hazard generated by current 

Manipulation of the Loxone Aquastar Air by operating staff is strictly prohibited 
and may only be performed by duly authorized staff, qualified for electrical 
work. Compliance with the corresponding instruction and prohibition signs is 
required. 
 

6.2  Hazard generated by human error 

The operating staff must be instructed in regard to the residual danger 
resulting from electricity and familiarized with correct operation. Efficiency of 
the safety training must be verified. 
 

6.3  Hazard generated by current during cleaning work 

Cleaning of the Loxone Aquastar Air may only be performed after 
disconnection from power supply (lever switch). 

 
 

  General 

7

 
Praher  Plastics  Austria  Aquastar  controls  are  significant  technical  products,  which  are 
manufactured with high accuracy to the most modern technical production methods. Entitled 
complaints  will  naturally  be  rectified  as fast  as  possible  if  they  occur.  The  equipment  has  a 
warranty after valid European law. The warranty begins with the purchase date. 

 
 
 
 
 
 
 

  Directions for use 

8

 
The following is a control unit for a 

Praher 6-way valve

 that is operated using a Loxone 

miniserver. The Loxone Aquastar Air backwashes a filter fully automatically via time and 
pressure and controls the pump of a swimming pool as well as various extensions for the 
Loxone control unit. 
 
An electrical connection for a Praher ball valve EO510, for opening during the cycle, is 
available. 
 

 
 
 
 

 
 

 

ATTENTION! For relief of the sealing system the valve is shipped on 

intermediate position and is not sealed! Prior to operation it has to be 

electrically set to position “Filter”! 

 

The Aquastar must never be operated without a Praher V6 valve to avoid 

damage to the device 

 

Содержание Loxone

Страница 1: ...Zertifiziert nach certified acc to EN ISO 9001 2008 SMART HOME READY...

Страница 2: ...8 Assembly 8 9 9 1 Function and installation diagram 8 Add the Device into the Loxone Config 9 10 10 1 Initial setup 9 10 2 Re learning in process 9 Electrical Connection 11 11 Technical data 12 12 C...

Страница 3: ...3 www praherplastics com...

Страница 4: ...amiliarization with the Loxone Aquastar Air and utilization of the same for the intended purpose This operation manual contains important information for safe proper and economical operation of the Lo...

Страница 5: ...user s facility in the installation dismantling putting into operation operation or maintenance of the Loxone Aquastar Air must have read and understood the entire operation manual and in particular...

Страница 6: ...ossible In this case the equipment is to be secured against unintentional start up and if necessary to be decommissioned Live parts can be uncovered when opening the cover or removing parts Before an...

Страница 7: ...ficant technical products which are manufactured with high accuracy to the most modern technical production methods Entitled complaints will naturally be rectified as fast as possible if they occur Th...

Страница 8: ...diagram 6 way valve type 11 2 und 2 Connections thread or solvent socket all connections open Max operating pressure ABS 11 2 2 3 5 bar GFK 11 2 2 6 bar Filtern der Fl ssigkeit z B Wasser Becken Pumpe...

Страница 9: ...time the learning mode will start automatically 10 2 Re learning in process To re learn the Loxone Loxone Aquastar Air simply press and hold the learn button for at least 5 seconds The Loxone Loxone A...

Страница 10: ...e and click on Create Device The device will now be listed in the Periphery tree The following objects are now available for configuration as part of the device itself Beyond the classic functions of...

Страница 11: ...5A at cos 1 30VDC 5A Use a Auxiliary relay at greater loads The potential free relays Rel1 to Rel3 are designed as NO contacts and act as a functional enhancement in the Loxone system e Pressure senso...

Страница 12: ...12 Voltage 100 240V AC 50 60 Hz Protection IP 65 Frequency 50 60 Hz Max Power 15 Watt 11 2 2 Connection diagram for pump and Praher ball valve EO510 13 13 1 Connection diagram for one phase pump 13 2...

Страница 13: ...13 www praherplastics com Circuitboards 14 14 1 Mainboard 14 2 Power Supply...

Страница 14: ...B 90 X 114 165 C 29 5 31 5 38 50 D 48 47 60 85 5 E 61 5 59 5 81 110 F 163 5 160 210 306 G 304 300 348 445 H 39 42 5 36 50 I 87 5 90 114 165 J 117 117 117 117 K 175 180 228 117 L 125 125 125 330 M 165...

Страница 15: ...astar Air 16 1 Aquastar lid with foam rubber cord 2 Hexagon screw 3 Gear motor 4 Aquastar body bottom 5 Cabel with Connector plug for pressure sensor 6 V6ND valve 1 2 7 Control board 8 Pressure sensor...

Страница 16: ...quastar Air 17 For dismantling the electronic drive off the valve a box spanner with a wrench size of 15mm is needed Carry out Installation in reverse order step 8 1 Inspection glas step 2 and hexagon...

Страница 17: ...1 16 63 50 109 121 38 5 124 5 16 Check valve S6 D DN A Z t D PN 50 40 77 87 31 5 101 5 16 63 50 87 99 38 5 115 3 16 PVC S6 DN 32 40 50 d 40 50 63 G 1 1 4 1 1 2 2 A 77 77 87 D 101 5 101 5 115 3 E 138 5...

Страница 18: ...ven at increased pressure The pump fails to switch on or off o Relay is burnt out The maximum pump current of 8A was exceeded o The pump is not properly connected The pump must always be looped via co...

Страница 19: ...19 www praherplastics com Notizen Notes...

Страница 20: ...Praher Plastics Austria GmbH BA DEEN 15 03 358 90454...

Отзывы: