8

heater.  Use the adhesive tape which is included
in the package to stick the pattern to the wall.
Keep in mind that the heater needs to have cer-
tain minimum clearances (See paragraph 7 on
this page), and that the heater must be level.  Drill
four holes into the wall at the studs (16 inches on
center) as indicated on the template.  Use a 1/8
inch drill if screws are to go directly into wood or
1/4 inch if plastic anchors are to be used.

WARNING:  Be sure to remove the paper
template before hanging the heater on the
wall.
After the paper template is removed, insert the
mounting screws into the two upper holes.  Leave
1/2 inch between the wall and the screw head, in
order to have enough space for your unit to slip
over.  The bottom screws will secure the Water
and Gas Connecting Strip Assembly to the wall.
Next remove the front panel.  To do this, remove
the temperature selector knob (H) and the pilot
starting button by pulling them out.  Unscrew the
screws under each front corner.  Lift the panel up
and pull out.  At this point, you can either screw
the two large screws to fasten the Water and Gas
Connecting Strip Assembly to the wall using the
pre-drilled holes and connect your pipes directly
to the water heater, or you can remove the heater
from the Water and Gas Connecting Strip Assem-
bly in order to connect the piping, and then re-
connect the heater later.  If you decide to connect
the pipes directly, skip the next section and go to
#3, "Connecting the Gas Line."

2. To Disconnect Heater From the Water and
Gas Connecting Strip Assembly (Optional)
Refer to figure 3 (following page).  Unscrew each
brass union nut at the three points marked in fig-
ure 3.  Be careful not to lose the washers.  Re-
move your heater from the Water and Gas Con-
necting Strip.  Now you can make your water and
gas connections as explained in the following
sections.  When all connections have been made,
re-hang the heater on the upper screws and re-
connect the brass union nuts making certain that
the washers are properly in place.

8.  For alcove installation, maintain the following
minimum clearances from all construction for ser-
vicing and proper operations:

Alcove             Closet

A. Top            6 inches          12 inches
B. Front         OPEN                6 inches
C. Back         0 inches             0 inches
D. Sides        1 inch                 1 inch
                       (Left side 6" for service)
E. Floor          6 inches*         12 inches*
F. Flue            6 inches             6 inches
                       (single wall only)

*Do not install over floor covering which is combustible,
such as carpet.

Minimum clearance to combustible materials
should not be less than 6" for single wall flue pipe.
Note that this can be reduced if combustible
materials are protected as per table VI of the
National Fuel Gas Code or if Type B gas vent is
used.  (Follow the minimum clearances for the
vent type.  We recommend the use of Type B gas
vent.

9. WARNING:  THIS WATER HEATER DOES
NOT STORE ANY HOT WATER.  DO NOT IN-
STALL IN AN AREA WHERE IT COULD
FREEZE.  This heater is neither designed for
nor approved for outside installation.

10. The heater must be level before you begin
the piping.

INSTALLATION

Before installing the unit, be certain your heater
is for your type of gas - Propane or Natural Gas.
Identification labels for type of gas are found on
the shipping box, on the right side panel and on
the rating plate which is located in upper part of
draft hood seen by removing front panel (See
"X" Fig. 2, page 6).  Also, each gas orifice is
stamped with a number (75 for LPG and 115 for
Natural Gas).

1. Hanging the heater on the wall
Place the paper pattern or template (supplied with
heater) on the wall where you plan to hang your

Содержание 80 VP

Страница 1: ...s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the...

Страница 2: ...burners and is ignited by the pilot flame The heat exchanger then absorbs the heat generated by the burners and transfers it to the cold water as it travels through the heat exchanger When the hot wat...

Страница 3: ...GAS PRESSURE FOR HIGH ALTITUDES The pressure regulator provided with the heater is set to deliver the proper gas pressure as indicated on the rating plate and in the manual for altitude up to 2500 fe...

Страница 4: ...stic potable water a mixing valve or other similar device must be provided to reduce scald hazard potential DO NOT CONVERT AN EXISTING CLOSED HOT WATER HEATING SYSTEM TO A COMBINATION SPACE AND POTABL...

Страница 5: ...days 9 Should overheating occur and the gas supply fail to shut off turn off the manual gas control valve to the appliance 10 See instructions on setting the water tempera ture page 12 11 Do not use...

Страница 6: ...P M Z K H J G F D E C B A I Y Fig 2 Parts of AquaStar 80 L T pilot V overheat shut off sensor W draft hood X rating plate serial gas type etc Y incandescent particles tray Z gas pressure testing nippl...

Страница 7: ...t water lines insulated 6 Having a floor drain or sink nearby is handy in case you need to drain water from your heater 7 Place the heater in a location where water leaks will do NO DAMAGE to adjacent...

Страница 8: ...reful not to lose the washers Re move your heater from the Water and Gas Con necting Strip Now you can make your water and gas connections as explained in the following sections When all connections h...

Страница 9: ...lator to the gas piping the indicator arrow on the regulator must be pointed in the direction of gas flow NOTE The regulator supplied with the heater is an appliance level regulator de signed for low...

Страница 10: ...lowing all local ordinances and specifications for installing a gas appliance vent or chimney The gasses to the outdoors under all operating con venting system must be constructed so as to develop a p...

Страница 11: ...r Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS 1 STOP Rea...

Страница 12: ...should be serviced periodically de pending on hardness of water and conditions of use or whenever signs of corrosion appear at the gas and water valve joint Servicing the water valve consists of repl...

Страница 13: ...column Yellow flames could be a sign of wrong size gas orifices or dirty burners If some burn ers have yellow flames while others have good flames it is likely that dust lint or spider webs have parti...

Страница 14: ...urnished with the heater is designed for low PILOT WILL NOT LIGHT 1 No gas to the AquaStar A Gas cock on gas line may not be open B AquaStar manual shut off valve at base of heater is not open Turn ha...

Страница 15: ...years old it is very unlikely that they are faulty Before testing reconfirm that 2 is absolutely cor rect and all connections are clean and tight To test the thermocouple disconnect the thermo couple...

Страница 16: ...e is good To test the electromagnet reconnect the thermo couple and take another reading The reading should drop to about 14 mv If it does not re place the electromagnet PILOT LIGHTS BUT GOES OUT DURI...

Страница 17: ...ature selector dial on 4 or 5 For more information see section on Setting Water Temperature Page 12 2 Inlet water temperature is too high as with preheated water Note Only the Model S AquaStar should...

Страница 18: ...t In such cases when mixing cold water at the tap the lower hot water pressure may be overpowered by a much higher cold water presure which may cause the AquaStar burners to shut down Make sure fau ce...

Страница 19: ...Housing b Insert the other Gasket between tube and Filter Housing c Use two wrenches to tighten Pilot Tube to Filter Housing 1 One wrench should hold Pilot Burner in right most position making sure ri...

Страница 20: ...4 Leaving temperature setting at 2 now increase water flow on higher You should see the burner flames increase in size and then decrease when you reduce the water flow 5 Note If all of the above perfo...

Страница 21: ...omponents O Ring and Steel Wedge prior to installing the replacement thermostat 1 Shut off gas to the heater by turning the handle on the main gas valve 2 Shut off the water supply to the heater and o...

Страница 22: ...s Flow Shut off Valve 14 provides a quick gas shut off right on the heater The gas shut off safety devices are integrated with the pilot light An Electro Magnet in the Gas Valve ensures thatgasflowsto...

Страница 23: ...LY 9 PILOTLIGHT 10 PILOTLIGHTORIFICE 11 PILOTLIGHTGASFILTER 12 THERMOCOUPLE 13 ELECTROMAGNET GAS FLOW SHUT OFF VALVE 14 MANUAL GAS FLOW SHUT OFF VALVE 15 PILOT STARTER KNOB 16 THERMOSTATIC MODULATOR A...

Страница 24: ...RIGHT SIDE PANEL 38799 LEFT SIDE PANEL 22527 TEMPERATURE SELECTOR KNOB 23617 PANELRETAINING SCREW 28329 PILOT STARTER KNOB 36540 FRONT PANEL 33993 INCANDESCENT PARTICLETRAY HOUSING COMPONENTS DIAGRAM...

Страница 25: ...LECTING STRIP 25776 WASHER 25779 HEAT EXCHANGER FRAME RETAINING SCREW 27126 WASHER 29596 THERMOCOUPLE ELECTROMAGNET LEAD WIRE TERMINAL RETAINING SCREW 29910 INLET WATER FLOW RESTRICTOR 31851 COLD HOT...

Страница 26: ...S 36546 BURNER MANIFOLD WITH LP INJECTORS 36548 LP GAS SLOW IGNITION MEMBRANE ASSEMBLY 36549 LP MAIN VALVE ASSEMBLY 36650 NG MAIN VALVE ASSEMBLY 37167 MODEL S GAS MAIN VALVE ASSEMBLY 37613 MODEL S NG...

Страница 27: ...opane Natural Gas Model 80 25 100 150 170 NR 25 80 Model 80 15 50 100 125 NR 20 50 100 170 NR NR 35 70 Flex tubing greatly reduces capacity and therefore is not recommended Minimum Vent Size and Heigh...

Страница 28: ...l use and service within the applicable periods specified below in accordance with the terms of this warranty The CEC replacement will be warranted for the unexpired portion of the original warranty T...

Отзывы: