Aqua-Swirl

®

 

 

 

TABULAR MAINTENANCE SCHEDULE 

 

Date Construction Started: 

 

 

 

 

 

 

 
Date Construction Ended: 

 

 

 

 

 

 

 

During Construction 

 

 

Month 

Activity 

10 

11 

12 

Inspect and Clean  

as needed

 

 

 

 

 

 

 

 

 

Inspect Bypass and 
maintain as needed

 

 

 

 

 

 

 

 

 

Clean System*

 

 

 

 

 

 

 

 

 

 

 

 

X* 

* The Aqua-Swirl

®

 should be cleaned 

once a year

 regardless of whether it has reached full pollutant storage 

capacity. In addition, the system should be cleaned at the 

end of construction

 regardless of whether it has reach full 

pollutant storage capacity. 
 

 

First Year Post-Construction 

 

 

Month 

Activity 

10 

11 

12 

Inspect and Clean  

as needed

 

 

 

 

 

 

 

 

 

Inspect Bypass and 
maintain as needed

 

 

 

 

 

 

 

 

 

Clean System*

 

 

 

 

 

 

 

 

 

 

 

 

X* 

* The Aqua-Swirl

®

 should be cleaned 

once a year

 regardless of whether it has reached full pollutant storage 

capacity.  
 

 

Second and Subsequent Years Post-Construction 

 

 

Month 

Activity 

10 

11 

12 

Inspect and Clean  

as needed

 

 

 

 

 

 

 

 

 

 

 

 

X* 

Inspect Bypass, 

maintain as needed

 

 

 

 

 

 

 

 

 

 

 

 

X* 

Clean System*

 

 

 

 

 

 

 

 

 

 

 

 

X* 

* If the Aqua-Swirl

®

 did 

not

 reach full sediment or floatable pollutant capacity in the First Year Post-Construction 

period, the system can be inspected and cleaned once annually. 
 
If the Aqua-Swirl

®

 

reached

 full sediment or floatable pollutant capacity in less than 12 months in the First Year 

Post-Construction period, the system should be inspected once every six (6) months or more frequently if past 
history warrants, and cleaned as needed. The Aqua-Swirl

®

 should be cleaned annually regardless of whether it 

reaches its full sediment or floatable pollutant capacity. 

Содержание Aqua-Swirl

Страница 1: ...Stormwater Treatment System Inspection and Maintenance Manual AquaShieldTM Inc 2733 Kanasita Drive Suite 111 Chattanooga TN 37343 Toll free 888 344 9044 Phone 423 870 8888 Fax 423 826 2112 Email info...

Страница 2: ...ype hydrodynamic separator designed and supplied by AquaShieldTM Inc AquaShieldTM Aqua Swirl technology removes pollutants including suspended solids debris floatables and free floating oil from storm...

Страница 3: ...ate to the center of the chamber where velocities are the lowest The treated flow then exits the Aqua Swirl behind the arched outer baffle The top of the baffle is sealed across the treatment channel...

Страница 4: ...formance of any stormwater treatment structure including manufactured or land based systems depends on a consistent maintenance plan Inspection and maintenance functions are simple and easy for the Aq...

Страница 5: ...n Procedure To inspect the Aqua Swirl a hook is typically needed to remove the manhole cover AquaShieldTM provides a customized manhole cover with our distinctive logo to make it easy for maintenance...

Страница 6: ...Cleanout Procedure Cleaning the Aqua Swirl is simple and quick Free floating oil and floatable debris can be observed and removed directly through the 30 inch service access riser provided A vacuum t...

Страница 7: ...tasks Disposal of Recovered Materials AquaShieldTM recommends that all maintenance activities be performed in accordance with appropriate health and safety practices for the tasks and equipment being...

Страница 8: ...oil due to the dark body of the surrounding structure Oil may appear darker than water in the system and is usually accompanied by oil stained debris e g Styrofoam etc The depth of oil can be measure...

Страница 9: ...the presence of known contaminants may necessitate that appropriate actions be taken to clean and dispose of materials captured and retained by the Aqua Swirl All cleaning activities should be perfor...

Страница 10: ...IV Bypass Structures Bypass structures should be inspected whenever the Aqua Swirl is inspected Maintenance should be performed on bypass structures as needed MAINTENANCE COMPANY INFORMATION Company...

Страница 11: ...ogging Yes No Describe Other Observations NOTES Additional Comments and or Actions To Be Taken Time Frame ATTACHMENTS Attach site plan showing Aqua Swirl location Attach detail drawing showing Aqua Sw...

Страница 12: ...as needed X X X X Clean System X The Aqua Swirl should be cleaned once a year regardless of whether it has reached full pollutant storage capacity Second and Subsequent Years Post Construction Month...