AquaScape Pond Powerhead Скачать руководство пользователя страница 5

aquascapeinc.com | 

 CAN (866) 766-3426 | 

 US (866) 877-6637

5

•  If running through winter conditions, check regularly to make sure it is functioning properly and ice is not forming around the 

pump.

•  In the event of a power failure, the powerhead should be removed to prevent any damage.
•  If concerned about possible freeze damage, disconnect and remove the powerhead. Clean with fresh water and store the 

pump in a frost-free location. 

Winter Application

•  Over time, depending on conditions, the powerhead may collect debris around the outside of the unit. Remove this debris 

from the outside of the unit to provide maximum water flow.

•  Outer/Inner Cage Cleaning:

 – Remove the single screw located at the center of the unit (Ex. 8). Depress all three external tabs and gently lift upward  
    to remove the front cage (Ex. 9).
 – Clean the exterior and interior of the cage to remove any existing debris or buildup. If needed, use Aquascape Pump  
    Cleaner Maintenance Solution (#91143) to remove stubborn buildup.

• Propeller Cleaning:

 – Remove the water chamber cover by rotating it counter-clockwise and gently pulling (Ex. 10).
 – Remove the propeller by pulling gently.
 – Clean the propeller and internal pump body with Aquascape Pump Cleaner Maintenance Solution (#91143), using a  
    sponge or soft-bristled brush.
 – When reinstalling the propeller, be sure to align the three tabs with the corresponding indentations before locking into  
    place (Ex. 11).
 – When reinstalling the cage, be sure to align the screw with the proper external tab.

General Maintenance

•  Plug the quick-connect 

fitting into a 12-Volt, 
outdoor-rated transformer 
or existing low-voltage 
system. The Pond 
Powerhead is designed to 
operate on a power source 
with a maximum operating 
range of 9V-15V. Operating 
the powerhead outside of 
this voltage range voids the product warranty (Ex.7).

Ex. 7

Ex. 6

#98998

#84023

#98489

#84022

A

A

B

B

2

2

1

1

A

A

B

B

2

2

1

1

Ex. 8

A

A

B

B

2

2

1

1

Ex. 9

A

A

B

B

2

2

1

1

Ex. 10

A

A

B

B

2

2

1

1

Ex. 11

Содержание Pond Powerhead

Страница 1: ...aquascapeinc com Pond Powerhead Item 91142 I N S T R U C T I O N S M A I N T E N A N C E POND POWERHEAD aquascapeinc com...

Страница 2: ...ety Information 3 Specifications Chart 4 Instructions 4 5 Winter Application 5 General Maintenance 5 Troubleshooting 6 Replacement Parts 6 Warranty Information 6 The Aquascape Pond Powerhead is design...

Страница 3: ...connect conduit to pump J Do not use power cable to lift pump Always operate the pump fully submerged Failure to do so may overheat the pump and cause it to fail voiding the warranty Use only in full...

Страница 4: ...n locations include stagnant areas with low water movement or debris build up Ex 2 Each time the powerhead turns on it will provide a slight recoil Therefore we recommend setting the unit in a locatio...

Страница 5: ...ebris or buildup If needed use Aquascape Pump Cleaner Maintenance Solution 91143 to remove stubborn buildup Propeller Cleaning Remove the water chamber cover by rotating it counter clockwise and gentl...

Страница 6: ...th a suitable replacement unit Units should be checked for proper operation prior to returning as defective No liability for loss or damage of any nature or kind whether arising out of or from the use...

Страница 7: ...aquascapeinc com Pond Powerhead R f rence 91142 I N S T R U C T I O N S E T E N T R E T I E N POND POWERHEAD aquascapeinc com...

Страница 8: ...n d placement d eau et emp cher l eau de stagner dans les bassins et les jardins aquatiques favorisant ainsi la circulation de l eau son agitation en surface et son a ration Cette pompe autonome ne n...

Страница 9: ...vez pas la pompe par le cordon d alimentation Lorsqu elle est utilis e la pompe doit toujours tre immerg e Si elle n est pas immerg e la pompe peut surchauffer et tomber en panne annulant ainsi la gar...

Страница 10: ...rie permettant ainsi une pose rapide et facile dans un accessoire aquatique nouveau ou existant Placez la ou les Pond Powerhead dans le bassin ou le jardin aquatique aux emplacements voulus Ex 2 Les e...

Страница 11: ...besoin utilisez la Pump Cleaner Maintenance Solution Aquascape no 91143 pour liminer les d p ts rebelles Nettoyage de la roue Retirez le couvercle de la chambre d quilibre en le faisant tourner dans...

Страница 12: ...d fectueux par un produit de rechange adapt Le bon fonctionnement du produit doit tre v rifi avant de le retourner comme tant d fectueux Aquascape Inc ou ses soci t s affili es ne sauraient tre tenue...