www.aquasafecanada.com   |   Maximus II Installation Instructions 05/13   |   page 15

page 14   |   Maximus II Installation Instructions 05/13   |   www.aquasafecanada.com 

that length of tubing into the remaining port of the 3 way “T” adapter (Step 2, Fig. 25). You don’t need 
to use all 30 feet if your tank is closer but if you leave all of it intact you can move your tank further 
away at a later date without purchasing a new length of tubing or a union adaptor.

On the other end of the same length of tubing you will need to cut away a 1 foot section. Make sure to 
cut straight - NOT at an angle.  Locate the remaining Manual Shut off Valve from your small parts bag 
and reconnect the 1 foot piece of cut tubing to the main length using the Manual shut off Valve (Step 
3, Fig. 25).  If you ever need to shut off flow of water to the float valve, the manual shut off valve will be 
your means to do so.

Next you will need to drill a 1/2 inch hole into the appropriate location of your plexiglass sump tank.  

Choose this location carefully!  when your sump is full the ball of the float should be 1/2 (HALF) sub-
merged. Pay attention to when choosing the mount location of the float valve.   When the ball of the 
float is half submerged, 

that

 is the point when it will cease the flow of water into your sump.  Installing 

the float a little too low is probably better than too high. Please pay close attention, take your time and 
make sure to chose the right location! 

You will need to have the float valve 
mounted before hooking the tubing up 
to the float valve.  The tubing hooks into 
the float valve by way of its compression 
nut fitting.  Insert the compression nut 
over the tubing and 1 inch down the tub-
ing in such a way that the threads inside 
the compression nut are facing the float 
valve (Fig. 26).

Next, slide the compression ferrule over 
the tubing.  Now screw the compression nut onto the shaft of the float valve.  Use a pair of pliers to 
tighten further to ensure the compression nut is doing its job to form the seal on the tubing.

b) Stainless Steel: Do the same as for laminate, except be really sure of your clearance space. Take a 
metal punch (or a big nail) and give the magic spot a good hit. At this indentation drill a pilot hole. 
A wood drill will not do it. You must use a metal drill bit suitable for stainless. Once the pilot hole is 
made, follow up with a ½” hole and attach the faucet.

c) Marble or Granite: This is not that hard, but takes some time. You need a diamond tipped drill and 
about 15-20 minutes. The price of a ½” diamond tipped drill is around $75.00. Since you will probably 
never use it again, you would probably be better off either renting the equipment or calling in a Pro

Most glass installers have diamond drills and all vendors of stone have them. Some will rent it out, as 
will “Rent-All” stores. Start the hole by drilling a ½” hole in a piece of scrap wood. This will serve as a 
guide. Hold the piece of wood and let the diamond drill bit do the work. DO NOT push down or apply 
pressure. Keep the hole filled with water and wipe out the hole often. It is important to let the weight 
of the drill be the pressure and to let it just grind away at its own pace (which is slow).

d) Wood: If you have a wood counter top you could of course drill out the hole just beside the sink.  
Also please keep in mind that you could run the 1/4 ” tubing to a location nearby your system.

Faucet diagram for further reference.

Follow the schematic above.  Use the other length of blue tubing that was cut in two pieces during 
step 11.0. When you have your Aquasafe faucet firmly in place in the chosen location, insert the tube 
leading from the faucet into the straight male adaptor on the left side of the Polishing Filter.

15.0 Connecting auto top-up Float Valve

Choose a point along the length of tubing that connects the tank to the male “T” of the final polish-
ing filter and cut the tube.  Make sure to cut straight - NOT at an angle. Now insert each of the two cut 
ends into two of the three ports of the 3 way “T” adapter found in small parts bag (Step 1, Fig. 25).
Next locate the

 

30 foot length of tubing (the coil that was NOT in a Parts Bag) and connect one end of 

Gooseneck

Spacer

Cover Plate

Rubber Seal

Notched Steel Washer

Nut

Plastic Ferrule

Compression Nut

Blue tubing

threads

Counter Top

tighten this nut over the threads

under the faucet

remove the 

protective

blue film after 

installation

Figure 24

Attaching the 

faucet

Figure 25

Running tubing to 

the Auto top-up 

Float Valve

Figure 26

Connect the Auto 

top-up Float Valve

If you have a glass sump you will simply need to clamp the float to the top of the glass sump.

TIP

1

2

Cut the blue tubing between the polishing filter

and the tank and insert the 3 Way T adaptor. 

Attach 30’ length of 

blue tubing to the 

3 Way T adaptor and 

direct it to your sump

tank or storage container.

3

Cut 1 foot of tubing off the end of the

blue tubing and insert a Manual Shut

Off Valve there

0 ppm aquarium water

Reservoir Tank

3 Way T

Auto top-up

Float Valve

SUMP TANK

Manual

Shut Off

Valve

www.aquasafecanada.com

Final Polishing Filter

1’

4

Attach the float valve to the sump tank 

and then the blue tubing to the float 

valve (see Figure 26) 

(or other water storage)

ring

steel washer

ferrule

compression nut

blue tubing

threads

-tighten this nut 

over the threads

Plexiglass sump

tank wall

Float Valve

to 

3 Way T

Содержание Aquarium II Dual R.O./D.I. System

Страница 1: ...commend a fully automatic booster pump which is found on our websites general parts and accessories page We also highly recommend a booster pump if your water is extremely turbid with ppm counts beyond 600ppm The installation instructions that follow are extremely detailed if a leak is experienced during installation please see the Leak Prevention Section on page 18 ATTENTION It is extremely impor...

Страница 2: ...l Reverse Osmosis System COMBO 1 0 Relax take your time You will find this process easy and straight forward 1 2 0 Take everything out of the box 2 3 0 Remove the protective plastic from the prefilters 2 4 0 Inserting the R O Membrane 3 4 1 Inserting the pre filter elbow adaptors 3 5 0 Preparing the Feed Water to your system 3 5 1 Special note about braided wire plumbing 4 5 2 Installing the Needl...

Страница 3: ...s water inlet side water outlet side Figure 5 Screw elbow adaptors into inlet and outlet of the pre filter housings www aquasafecanada com Insert blue RO Membrane into housing Screw cap on housing 1 2 Membrane housing blue RO Membrane Cap Figure 4 Inserting the R O Membrane in to its housing TIP 2 0 Take everything out of the box Examine the contents of the Large and Small Parts Bag against the di...

Страница 4: ...view 5 1 Special note about braided wire plumbing Please Note DO NOT ATTEMPT TO INSTALL THE NEEDLE PIERCING SADDLE CLAMP TO BRAIDED WIRE PLUMBING Fig 6 You can install the needle piercing saddle clamp to all other forms of cold water lines found under the common sink just not the kind of plumbing de picted in Fig 6 The braided plumbing in Fig 6 is too soft a material and will therefore not allow f...

Страница 5: ... for clarity 1 2 Put a bowl or bucket under the short piece of blue tubing coming out of the ASV to catch the PERMEATE water cleaned by the R O Membrane E Z Flush Flow Restrictor Close the E Z Flush Flow Restrictor and turn the Manual Shut Off Valve on blue tubing Manual Shut Off Valve to water supply 3 Figure 12 Preparing to set up the E Z Flush Flow Restrictor You can now turn your home s emerge...

Страница 6: ...n do ing this timed measurement the permeate water should take three times as long to fill the same volume over that of the brine water 3 1 Ratio We do not recommend anything over a 1 1 ratio as it is extremely important for the R O Membrane to have adequate BRINE flow to be able to flush away the harmful particulates it is removing while filtering the water A setting near to or at 1 1 ratio is on...

Страница 7: ... I Canister and connect it to the second D I Canister using a 4 inch length of blue tube 3 Connect the last elbow to the right side of the third D I Canister www aquasafecanada com D I Canisters rotated back to make room elbow elbow www aquasafecanada com The Final Polishing Filter remineralizes your water to ensure it has a full bod ied taste Because of this the ppm of the water dispensed at your...

Страница 8: ...mply press the saddle clamp firmly onto the drain in order to catch the bolts on the opposite side TIP Figure 23 Assembling and attaching the drain saddle clamp rubber gasket quick connect fitting drain pipe yellow drain line Insert yellow drain line into quick connect fitting rubber gasket 1 2 Remove the backing from the gasket and stick it to the inside of the saddle clamp making sure that the y...

Страница 9: ...ver use it again you would probably be better off either renting the equipment or calling in a Pro Most glass installers have diamond drills and all vendors of stone have them Some will rent it out as will Rent All stores Start the hole by drilling a hole in a piece of scrap wood This will serve as a guide Hold the piece of wood and let the diamond drill bit do the work DO NOT push down or apply p...

Страница 10: ...all the PSI Meter onto your system there one area where installing the PSI Meter on your system can be of use Option 1 If you are on a well water system and you think you may have lower then 50 psi through out your home s plumbing a good place to install the PSI Meter is on the feed water line to your Reverse Osmosis System between the Manual Shut Off Valve and the inlet to the first pre filter ho...

Страница 11: ...II Dual System Filter Change Schedule Pre Post filters Defined as the filter stages Pre before RO Membrane and Post after RO Membrane Stage 1 2 3 Pre Filters When to conduct a filter change Stages 1 2 and 3 are your system s pre filters which need to be changed every 1000 gallons of purified water produced The average household consumes 3 5 gallons of drinking and cooking water daily At 5 gallons ...

Страница 12: ...er back ON with the Manual Shut Off Valve NOTE Back View hanging bracket not shown for clarity Manual Shut Off Valve in OFF position E Z Flush Flow Restrictor feed water in yellow tubing to discharge saddle clamp 3 TDS Meter Figure 29 How to depressurize your system Figure 30 Testing your permeate water with the TDS meter WARNING Are you unsure when you last replaced your R O Membrane Because the ...

Страница 13: ...re filters for 10 15 minutes 4 5 feed water in yellow tubing to discharge saddle clamp DONE After the 10 15 minute flush turn Manual Shut Off Valve back OFF and reconnect the white and yellow tubes to their original positions If this is the only filter change you are doing at this time you can turn the Manual Shut Off Valve and Tank Top Valve back ON and you are to faucet 3 Way T www aquasafecanad...

Страница 14: ...y pushing the canister down onto its canister clips Repeat for second and third D I Canisters Reinsert the blue tubing into the elbows on both sides of the D I Resin Canister Turn on the Manual Shut Off Valve and Tank Top Valve to repressurize your system Figure 36a Replacing the D I Resin Beads If you are done replacing filters for now you can re pressurize your system by turning on the feed wate...

Страница 15: ...ceeds 113 F 45 C The membrane is not subjected to a pH lower then 4 or higher then 11 The membrane is exposed to water pressure greater then 150 psi The membrane is allowed to dry out after its initial wetting The Membrane should always be kept moist after its initial exposure to water If the membrane is exposed to greater than 1500 PPM water BOOSTER PUMPS Reverse Osmosis Booster Pumps are warrant...