background image

www.aquasafecanada.com   |   Maximus II Installation Instructions 05/13   |   page 3

page 2   |   Maximus II Installation Instructions 05/13   |   www.aquasafecanada.com 

If need be you can use a pair of needle nose pliers or similar tool to grip the white cylinder pro-

truding from the base of the RO Membrane to gain the leverage needed to push the membrane 
entirely into its proper position.

4.0  Inserting the R.O. Membrane

The R.O. Membrane is shipped sealed for 
freshness. Remove the R.O. Membrane 
from its sealed plastic bag and insert the 
membrane firmly into the R.O. Housing 
(see Fig 4). It can only go in one way, the 
end with the two small o-rings is to be 
inserted first.

Please Note:  It is extremely important 
the two small black “O” rings on the tip 
of the membrane seal tightly into place 
inside the membrane housing.  Please 
make sure to insert the membrane as 
firmly as possible into the membrane 
housing.

When you are certain the Reverse Osmosis 
Membrane is firmly in place screw the R.O. 
Membrane housing cap back into its place (Fig 
4) and then tighten with reasonable force using 
the small canister wrench from the Large Parts 
Bag.

4.1  Inserting the pre-filter elbow adaptors

Using two of the elbow adaptors from the Small 
Parts Bag, screw one of them into the “INLET” 
(left) side of the three pre-filters (Fig. 5) and the 
other into the “OUTLET” (right) side of the three 
pre-filters (Fig 5). 

Please note: Apply 4-7 wraps of Teflon 

tape, found in the Large Parts Bag, on each of 
the elbow adaptors 

throughout this installation

 

to prevent any possible leaks.

5.0  Preparing the Feed Water to your system

Found under your sink are the water supply shut off valves to your hot and cold water lines. You will 
need to SHUT OFF the cold water valve. Run the hot water for 30 seconds and then feel which line un-
der your sink is warm. SHUT OFF the opposite water line – since that will be the cold water line. After 
this valve is off, turn on your sink’s cold water tap to make sure there is NO cold water flowing from 
your kitchen sink faucet. If you shut the valve off correctly, there should be no cold water flowing.

www.aquasafecanada.com

Insert elbows into the inlet and outlet

ports on either end of the prefilter 

housings

“water 

inlet”

side

“water 

outlet”

side

Figure 5

Screw elbow 

adaptors into inlet 

and outlet of the 

pre-filter housings

www.aquasafecanada.com

Insert blue RO Membrane

into housing

Screw cap 

on housing

1

2

Membrane housing

blue RO Membrane

Cap

Figure 4

Inserting the R.O. 

Membrane in to 

its housing

TIP

2.0  Take everything out of the box

Examine the contents of the Large and Small Parts Bag against the diagrams below. If any pieces are 
missing, check the box, sometimes the pieces can fall out of their bags during the system’s journey to 
you. Note that there is an extra length of 30’ of blue tubing (for running a line to your aquarium sump 
tank) plus a float valve not packed in either of the Parts Bags.

 

3.0  Remove the protective plastic from the prefilters

Inside each of the three prefilter canisters you will find a prefilter with protective plastic for quality as-
surance purposes. Paying close attention to how the filter is sitting inside the prefilter housing, remove 
the plastic and then reinsert the prefilter the same way the prefilter was taken out. Do this one at a 
time. If by chance you loose track of which filter goes into which prefilter canister, the SED (sedimen-
tary filter) is stage one, the GAC (granular activated carbon filter) is stage two and the CCB (coconut 
carbon block filter) is stage three. See pictures below of the three prefilters. The GAC is the only one 
of the three prefilters that only goes in one way.  The GAC must be placed with the gasket up and the 
plastic mesh down.

With the prefilters inside each prefilter canister, carefully screw the canisters into place. Try to keep the 
prefilters centered as much as possible during this process. Now, using the large canister wrench from 
the Large Parts Bag, tighten each of the prefilters with reasonable force in order to seal the filters into 
place.

1

3

2

8

7

6

4

5

1

3

2

8

7

6

4

5

1

3

2

8

7

6

4

5

1

3

2

8

7

6

4

5

1

3

2

8

7

6

4

5

Figure 1

Small Parts Bag

Figure 2

Large Parts Bag

Figure 3

The three  

pre-filters

3.  3X 4 inch blue tubing;
4.  3 inch red tubing          

4.  8X canister clips
       

5.  straight male adaptor
6.  T adaptor

7.  3 way T adaptor
8.  8X elbow adaptors

5.  drain saddle 

clamp

6.  teflon tape
7.  blue tubing

1.  2X manual 
     shut off valve

2.  tank top
     valve

1.  needle piercing 

saddle clamp

2.  small canister 

wrench

3.  large canister 

wrench

1

2

3

6

7

4

5

Sedimentary Filter (SED)

Granular Activated Carbon (GAC)

Coconut Carbon Block (CCB)

Содержание Aquarium II Dual R.O./D.I. System

Страница 1: ...commend a fully automatic booster pump which is found on our websites general parts and accessories page We also highly recommend a booster pump if your water is extremely turbid with ppm counts beyond 600ppm The installation instructions that follow are extremely detailed if a leak is experienced during installation please see the Leak Prevention Section on page 18 ATTENTION It is extremely impor...

Страница 2: ...l Reverse Osmosis System COMBO 1 0 Relax take your time You will find this process easy and straight forward 1 2 0 Take everything out of the box 2 3 0 Remove the protective plastic from the prefilters 2 4 0 Inserting the R O Membrane 3 4 1 Inserting the pre filter elbow adaptors 3 5 0 Preparing the Feed Water to your system 3 5 1 Special note about braided wire plumbing 4 5 2 Installing the Needl...

Страница 3: ...s water inlet side water outlet side Figure 5 Screw elbow adaptors into inlet and outlet of the pre filter housings www aquasafecanada com Insert blue RO Membrane into housing Screw cap on housing 1 2 Membrane housing blue RO Membrane Cap Figure 4 Inserting the R O Membrane in to its housing TIP 2 0 Take everything out of the box Examine the contents of the Large and Small Parts Bag against the di...

Страница 4: ...view 5 1 Special note about braided wire plumbing Please Note DO NOT ATTEMPT TO INSTALL THE NEEDLE PIERCING SADDLE CLAMP TO BRAIDED WIRE PLUMBING Fig 6 You can install the needle piercing saddle clamp to all other forms of cold water lines found under the common sink just not the kind of plumbing de picted in Fig 6 The braided plumbing in Fig 6 is too soft a material and will therefore not allow f...

Страница 5: ... for clarity 1 2 Put a bowl or bucket under the short piece of blue tubing coming out of the ASV to catch the PERMEATE water cleaned by the R O Membrane E Z Flush Flow Restrictor Close the E Z Flush Flow Restrictor and turn the Manual Shut Off Valve on blue tubing Manual Shut Off Valve to water supply 3 Figure 12 Preparing to set up the E Z Flush Flow Restrictor You can now turn your home s emerge...

Страница 6: ...n do ing this timed measurement the permeate water should take three times as long to fill the same volume over that of the brine water 3 1 Ratio We do not recommend anything over a 1 1 ratio as it is extremely important for the R O Membrane to have adequate BRINE flow to be able to flush away the harmful particulates it is removing while filtering the water A setting near to or at 1 1 ratio is on...

Страница 7: ... I Canister and connect it to the second D I Canister using a 4 inch length of blue tube 3 Connect the last elbow to the right side of the third D I Canister www aquasafecanada com D I Canisters rotated back to make room elbow elbow www aquasafecanada com The Final Polishing Filter remineralizes your water to ensure it has a full bod ied taste Because of this the ppm of the water dispensed at your...

Страница 8: ...mply press the saddle clamp firmly onto the drain in order to catch the bolts on the opposite side TIP Figure 23 Assembling and attaching the drain saddle clamp rubber gasket quick connect fitting drain pipe yellow drain line Insert yellow drain line into quick connect fitting rubber gasket 1 2 Remove the backing from the gasket and stick it to the inside of the saddle clamp making sure that the y...

Страница 9: ...ver use it again you would probably be better off either renting the equipment or calling in a Pro Most glass installers have diamond drills and all vendors of stone have them Some will rent it out as will Rent All stores Start the hole by drilling a hole in a piece of scrap wood This will serve as a guide Hold the piece of wood and let the diamond drill bit do the work DO NOT push down or apply p...

Страница 10: ...all the PSI Meter onto your system there one area where installing the PSI Meter on your system can be of use Option 1 If you are on a well water system and you think you may have lower then 50 psi through out your home s plumbing a good place to install the PSI Meter is on the feed water line to your Reverse Osmosis System between the Manual Shut Off Valve and the inlet to the first pre filter ho...

Страница 11: ...II Dual System Filter Change Schedule Pre Post filters Defined as the filter stages Pre before RO Membrane and Post after RO Membrane Stage 1 2 3 Pre Filters When to conduct a filter change Stages 1 2 and 3 are your system s pre filters which need to be changed every 1000 gallons of purified water produced The average household consumes 3 5 gallons of drinking and cooking water daily At 5 gallons ...

Страница 12: ...er back ON with the Manual Shut Off Valve NOTE Back View hanging bracket not shown for clarity Manual Shut Off Valve in OFF position E Z Flush Flow Restrictor feed water in yellow tubing to discharge saddle clamp 3 TDS Meter Figure 29 How to depressurize your system Figure 30 Testing your permeate water with the TDS meter WARNING Are you unsure when you last replaced your R O Membrane Because the ...

Страница 13: ...re filters for 10 15 minutes 4 5 feed water in yellow tubing to discharge saddle clamp DONE After the 10 15 minute flush turn Manual Shut Off Valve back OFF and reconnect the white and yellow tubes to their original positions If this is the only filter change you are doing at this time you can turn the Manual Shut Off Valve and Tank Top Valve back ON and you are to faucet 3 Way T www aquasafecanad...

Страница 14: ...y pushing the canister down onto its canister clips Repeat for second and third D I Canisters Reinsert the blue tubing into the elbows on both sides of the D I Resin Canister Turn on the Manual Shut Off Valve and Tank Top Valve to repressurize your system Figure 36a Replacing the D I Resin Beads If you are done replacing filters for now you can re pressurize your system by turning on the feed wate...

Страница 15: ...ceeds 113 F 45 C The membrane is not subjected to a pH lower then 4 or higher then 11 The membrane is exposed to water pressure greater then 150 psi The membrane is allowed to dry out after its initial wetting The Membrane should always be kept moist after its initial exposure to water If the membrane is exposed to greater than 1500 PPM water BOOSTER PUMPS Reverse Osmosis Booster Pumps are warrant...

Отзывы: