background image

INSTALLATION AND OPERATING INSTRUCTIONS  

3

 

 

1

2 + 3

4

6

7

9

14c

14b

14a

14d

10

11

12

13

8

5

15

Model 

AQP-TAP-4G - 4 Way Tap

   

Ref 

Description 

 

 

 

     Qty

1             Tap  

1

2  

Mains Cold Water Connection (Letter C engraved) 

1

3  

Mains Hot Water Connection (Letter H engraved) 

1

4  

Cold Filtered Water Shank with Brass Adapter  

5  

Ambient Filtered Water Shank  

1

Filtered Water Lever 

1

7  

Mains Water Hot & Cold Lever 

1

8  

Aerator (located in outlet) 

1

Fittings

9  

Flexible Metal connectors 

 2

10 

Brass Adapter Red Washer 

1

11 

Brass Adapter 

1

12 

1/4 inch Quick Connection Piece Black O-ring 

2

13 

1/4 inch Quick Connection Piece 

2

14  

Mounting set: 

 

   a. Mixer base with o-ring 

 

   b. Fixing plate washer 

 

 

   c. Fixing plate 

 

   d. Locking Nut 

1

15 

Quick Connect T Piece 

1

Содержание AQP-TAP-4G

Страница 1: ......

Страница 2: ...d ensure that the manual is kept in a safe place for future reference The faucet must be properly installed and located in accordance with the installation instructions before it is used Due to manufacturing alterations actual product may vary from that pictured License Number WMKA21678 AQUAPORT SELECT 3 STEP SYSTEM Aquaport has developed a premium range of tap mixers to suit your home or office d...

Страница 3: ...isolating tap in accordance with local authority installation codes Wipe tap in one direction only applying minimal pressure on tap Use only a soft dry cloth with warm soapy water to clean the surface of the tap Never use harsh detergents or abrasive cleaners To maintain tap lacquer use a soft cloth or wipe over tap with warm soapy water to remove surface dust where tap remains dry Note Recommende...

Страница 4: ...hank with Brass Adapter 1 5 Ambient filtered Water Shank 1 6 Filtered Water Lever 1 7 Mains Water Hot Cold Lever 1 8 Aerator located in outlet 1 Fittings 9 Flexible Metal connectors 2 10 Brass Adapter Red Washer 1 11 Brass Adapter 1 12 1 4 inch Quick Connection Piece Black O ring 2 13 1 4 inch Quick Connection Piece 2 14 Mounting set a Mixer base with o ring 1 b Fixing plate washer 1 c Fixing plat...

Страница 5: ...red Water Shank with Brass Adapter 1 5 Ambient Filtered Water Shank 1 6 Filtered Water Lever 1 7 Mains Water Hot Cold Lever 1 8 Aerator located in outlet 1 Fittings 9 Flexible Metal connectors 2 10 Brass Adapter Red Washer 1 11 Brass Adapter 1 12 1 4 inch Quick Connection Piece Black O ring 2 13 1 4 inch Quick Connection Piece 2 14 Mounting set a Mixer base with o ring 1 b Fixing plate washer 1 c ...

Страница 6: ...s Water D Flexible Metal Connectors E Cold Filtered Water Shank F Ambient Filtered Water Shank G Quick Connect T Piece H 1 4 inch tubing I Filtration System J Undersink Chiller Water Inlet K Undersink Chiller Water Outlet Filter System Tubing and Undersink Chiller System sold separately A B C D E F G I J K H ...

Страница 7: ...through the Mixer Base 14a Note Check to make sure the mixer base o ring is still present and is fully seated in place 5 Mount the tap onto the sink hole by threading the Flexible Metal Connectors 9 and tap shanks 4 5 through the sink hole and position the Mixer base 14a between the sink and the tap 6 Ensure that the Flexible Metal Connectors 9 are positioned towards the front of the sink with the...

Страница 8: ...ected to the Mains Hot Water Connection 3 inlet on the tap and connect the Flexible Hose Connector to the mains hot water supply line IMPORTANT Re check to make sure hot and cold mains water connections are correct 13 Connect Tubing connections from your filtration system and undersink chiller to the ends of the Quick Connection Pieces connected to the ends of the Ambient and Cold Filtered Water S...

Страница 9: ...he undersink chiller unit to the tap Cold Filtered Water Shank connection 5 Measure 3 4 inch 19 05mm from the ends of the tubing and mark with a pencil Fig 2 6 Push the tubing firmly into the quick connection fittings on the Filter System Quick Connect T Piece and Tap connections until the pencil mark is pushed next to the collet or until tubing is fully seated Fig 2 If tubing is removed re cut th...

Страница 10: ...bing Installation Connection needs thread tape Unscrew the Quick Connection Piece and place thread tape around the tap shanks in a clockwise direction reassemble Quick Connection Piece and install tube Faulty Tap If tap is leaking at the tap handle please contact Aquaport No Water Flow Shut off valve is switched off Please make sure that the shut off valve on your filtration system is open Mains W...

Страница 11: ...nds only to repairing or replacing any component that proves to be defective in material or workmanship 3 Product must be installed by a licensed plumber and in accordance to relevant National Standards and State Regulations Note We recommend a qualified licensed plumber install the system who is prepared to guarantee their workmanship 4 Product must be fully installed in accordance with the user ...

Страница 12: ...replace outlet aerator inserts etc 15 Warranty does not cover damage or malfunctions of tap ceramic cartridge due to the presence in the water supply of a Copper tube pieces b Sand dirt or stones c Thread tape d Other objects not normally present on potable water supplies e Water pressure exceeding 1000kpa 16 Warranty does not cover products which have been attached via the end of the spout to any...

Страница 13: ...INSTALLATION AND OPERATING INSTRUCTIONS 11 ...

Страница 14: ...CUSTOMER HOTLINE 1300 764 325 Aquaport Corporation Pty Ltd PO Box 81 Findon SA 5023 Australia Telephone 1300 764 325 Facsimile 08 8354 0722 Email aquaport aquaport com au Web www aquaport com au ...

Отзывы: