Technical parameters of the controller
Voltage
AC 220V ± 15% 50 Hz
Power consumption
≤2 W
Operating temperature range
0-
45ºC
Interval operating humidity
≤85%
The load capacity of the output contacts
5A / 250VAC (constant load)
d.
Indication of the controller
The drawing below shows the panel with the indicators responsible for following
functions and parameters:
°
C-temperature display, indicating that the displayed value is the current value of the
fluid temperature.
μS/cm (mkSm /
cm) - Indication of conductivity values, indicating that the
displayed value is the value of the conductivity produced at the moment.
M1 (feed pump) - Indication of the feed pump displays as ON state.
INLET VALVE - Indication of the inlet solenoid valve, it displays as ON state.
M2 (high pressure pump) - Indication of the high pressure pump, displays as ON state.
FLUSH VALVE (flushing valve) - indication of the flush solenoid valve, displays as
ON state.
FULL - indication of the filling process of the permeate tank, shows the upper limit
level of permeate in the tank.
LOW FEED PRESS (LOW PRESSURE OF WATER SUPPLY) - The alarm indicator
of low water level. The indicator lights in the absence or lack of water in the raw
water tank.
LOW PRESS (low pressure) - Indication of the pressure sensor at the entrance to the
high pressure pump. The indicator lights when the pressure of the water supply is too
low on the enterance of the high pressure pump.
HIGH PRESS (high pressure) - Indication of abnormal high pressure at the pump
outlet. The indicator lights when the pressure is too high at the outlet of the high
pressure pump (for
a model with index “S” transducer is
not included).
CD max (max. conductivity) - the alarm of exceeding the limit of conductivity.
SLP (sleep\waiting) - the system is in standby mode.
FULL (shown in the sign display) full tank of water, lit the lamp «FULL».