Achieve the ratio of permeate and concentrate up to 70/30% (60/40, 80/20, etc. 
depends on salinity, requirements for the quality of purified water, and the type of the 
membrane element). The output capacity of the permeate should be 

~ 125-375 liters / 

h, and concentrate should be 180 to 540 l / h, depending on the model. 

Attention: 

Depending on the raw water quality and the type of membranal elements, 

the ratio of concentrate and permeate can be changed. The optimum ratio of permeate 
and concentrate can be provided after a full water analysis in order to evaluate the 
quantity of cations and anions of the dissolved salts.

 

If the flow of concentrate or permeate is not correspond to the values, adjust the 
flows of valves RV-02 and RV-03. Changing the flows and/or increasing the permeate 
flow will result in scaling, which will reduce the interval between the cleaning 
treatment and reduce the life of the RO membranes.

 

 

7.5.3

 

Check the working pressure and compare it with the results of the first test and 

the technical characteristics.

 

7.5.4

 

Check the presence of water at the outlet.

 

7.5.5

 

Check the system for leaks, remove them if necessary. Before working de- 

energized the system, release the pressure.

 

7.5.6

 

Check the concentrate flow.

 

Note: After the start of operation, write the display values of the RO system, they can 
help to predict the regulation for system maintenance.

 

 

7.6 Operation

 

7.6.1 Pressure and the degree of regeneration.

 

The system works at a design pressure. The operator must adjust the release valve of 
the concentrate so that the operating pressure should be 100-250 PSI (depending on 
the type of membrane), a maximum of 250 PSI and flow permeate should be 50-90% 
of the feed water flow. Guided by the following principles:

 

7.6.1.1.1

 

Pressure in the system should not be more than maximum allowable.

 

7.6.1.1.2

 

The capacity of the concentrate will be in the operation range.

 

7.6.1.1.3

 

Productivity for purified water (permeate) is calculated according to 

temperature of raw water.

 

7.6.1.1.4

 

If the flow of permeate and total water consumption is reduced, system must 

be flushed.

 

 

7.6.2

 

Replacement of membranes. 

Содержание APRO S-125

Страница 1: ...toi 2A Sillam e 40231 Estonia www pro aquaphor com International 372 356 2204 21 Skype aquaphor market pro e mail market pro aquaphor com REVERSE OSMOSIS SYSTEM APRO series Installation and operation...

Страница 2: ...ystem Aquaphor 7 INSTALLATION REVERSE OSMOSIS SYSTEM 7 1 Attention 7 2 Connection 7 3 Start up 7 4 Security measures 7 5 Commissioning 7 6 Operation 7 7 Maintenance operations at shutdown 7 8 Mode 8 C...

Страница 3: ...ater treatment For proper operation it requires pretreatment Materials of RO systems are safety non toxic and do not release to the water any dangerous substances to health or the environment 2 ASSIGN...

Страница 4: ...verse osmosis system Aquaphor model T RO X Y L Z Q Q Designation Content designation Transcript notation T Trade name availability AP Aquaphor Professional RO Type of system Reverse osmosis X Type of...

Страница 5: ...of elements AP RO S 125 AP RO S 250 AP RO S 375 AP RO S 500 F01 F02 Filter housing Gross10 20 2 2 2 2 Polypropylene 5 mkr 1 1 1 1 Carbon filter B510 520 13 1 1 1 1 LPS 01 LPS 02 Low pressure switch P6...

Страница 6: ...REATMENT L Tolstoi 2A Sillam e 40231 Estonia www pro aquaphor com International 372 356 2204 21 Skype aquaphor market pro e mail market pro aquaphor com Control panel 220 380 1 1 1 1 Frame 1 1 1 1 Pas...

Страница 7: ...trate NPT 5 REQUIREMENTS FOR THE QUALITY OF SOURCEWATER 5 1 Chlorine If the water is chlorinated you need to install a carbonfilter 5 2 Hardness If water hardness exceeds 20 ppm it is necessary to est...

Страница 8: ...Not more 5 SDI Mineral oil Salinity TDS 5000 mg l Fe total Not more than 0 1mg l Oxidizers chlorine ozone KMnO4 Not more than 0 1 mg l Manganese Mn Not more than 0 05 mg l Organic impurities Not more...

Страница 9: ...rder to keep the water feed rate and also to avoid ingress of chlorine solid particles in the membrane modules Replacement instructions Shut off the system from electricity make sure there is no press...

Страница 10: ...cteria and other impurities from the water with the aim of purification or desalting It is based on the principle of separation of permeate clean water and concentrate dirty water through the membrane...

Страница 11: ...RV 01 Pump pressure regulation valve LPS01 Low pressure switch RV 02 Concentrate flow regulation valve LPS02 Low pressure after filtration RV 03 Recirculation flow regulation valve XV 01 Solenoid inl...

Страница 12: ...tional 372 356 2204 21 Skype aquaphor market pro e mail market pro aquaphor com AQUAPHOR PROFESSIONAL WATER TREATMENT Technical drawing of a reverse osmosis system Aquaphor model AP RO S 125 Technical...

Страница 13: ...tional 372 356 2204 21 Skype aquaphor market pro e mail market pro aquaphor com AQUAPHOR PROFESSIONAL WATER TREATMENT Technical drawing of a reverse osmosis system Aquaphor model AP RO S 375 Technical...

Страница 14: ...nstalled should be between 4 45 C The level in the tank with permeate must not be higher than 1 5m above the level of the permeate line exit from the membrane otherwise the system may malfunction for...

Страница 15: ...ed 7 4 5 It is forbidden to make any installation and or change of the system whileit works 7 5 Commissioning 7 5 1 Prepare to work carry out in manual mode New RO membranes are soaked with conserving...

Страница 16: ...tment and reduce the life of the RO membranes 7 5 3 Check the working pressure and compare it with the results of the first test and the technical characteristics 7 5 4 Check the presence of water at...

Страница 17: ...7 7 1 Short shutdown 1 3 days When the ambient temperature is 5 35 C you can turn off the system as a normal shutdown After turning the system on the RO system should operate for at least 1 2 hours 7...

Страница 18: ...d is activated by turning in the direction of the arrows which is drawn on it typically clockwise To re power the RO system is necessary to press the switch EMERGENCY STOP To reset the conductivity co...

Страница 19: ...lve it displays as ON state M2 high pressure pump Indication of the high pressure pump displays as ON state FLUSH VALVE flushing valve indication of the flush solenoid valve displays as ON state FULL...

Страница 20: ...e error lights the lamp ALARM Display panel controller SET button parameter setting selection of the parameters to change the display circular selection discharge thousands hundreds tens and units sel...

Страница 21: ...connection will damage the contact or shorten its life Designation ZJ intermediate relay CJ magnetic contactor The drawing shows the connectors which are located on the rear panel The panel is equippe...

Страница 22: ...is not used lock out the contacts 5 and 8 6 The reset signal can be connected to the reset button on the control panel which uses to unlock and reset the alarm in the event of high or low pressure 8 t...

Страница 23: ...of 0 99 hours If set to 03 the system will flush the membrane every 3 hours of continuous operation or standby mode If you are not satisfied with the parameters you can change them using the buttons a...

Страница 24: ...art with a pause which you choose when the valve is fully closed This is done with a purpose in order to prevent shutdown of the system by work out sensors feed water and exhaustion the formation of a...

Страница 25: ...stoi 2A Sillam e 40231 Estonia www pro aquaphor com International 372 356 2204 21 Skype aquaphor market pro e mail market pro aquaphor com AQUAPHOR PROFESSIONAL WATER TREATMENT Electrical drawings 380...

Страница 26: ...stoi 2A Sillam e 40231 Estonia www pro aquaphor com International 372 356 2204 21 Skype aquaphor market pro e mail market pro aquaphor com AQUAPHOR PROFESSIONAL WATER TREATMENT Electrical drawings 380...

Страница 27: ...stoi 2A Sillam e 40231 Estonia www pro aquaphor com International 372 356 2204 21 Skype aquaphor market pro e mail market pro aquaphor com AQUAPHOR PROFESSIONAL WATER TREATMENT Electrical drawings 380...

Страница 28: ...stoi 2A Sillam e 40231 Estonia www pro aquaphor com International 372 356 2204 21 Skype aquaphor market pro e mail market pro aquaphor com AQUAPHOR PROFESSIONAL WATER TREATMENT Electrical drawings 380...

Страница 29: ...stoi 2A Sillam e 40231 Estonia www pro aquaphor com International 372 356 2204 21 Skype aquaphor market pro e mail market pro aquaphor com AQUAPHOR PROFESSIONAL WATER TREATMENT Electrical drawings 230...

Страница 30: ...stoi 2A Sillam e 40231 Estonia www pro aquaphor com International 372 356 2204 21 Skype aquaphor market pro e mail market pro aquaphor com AQUAPHOR PROFESSIONAL WATER TREATMENT Electrical drawings 230...

Страница 31: ...stoi 2A Sillam e 40231 Estonia www pro aquaphor com International 372 356 2204 21 Skype aquaphor market pro e mail market pro aquaphor com AQUAPHOR PROFESSIONAL WATER TREATMENT Electrical drawings 230...

Страница 32: ...stoi 2A Sillam e 40231 Estonia www pro aquaphor com International 372 356 2204 21 Skype aquaphor market pro e mail market pro aquaphor com AQUAPHOR PROFESSIONAL WATER TREATMENT Electrical drawings 230...

Страница 33: ...www pro aquaphor com International 372 356 2204 21 Skype aquaphor market pro e mail market pro aquaphor com AQUAPHOR PROFESSIONAL WATER TREATMENT Dimensions specifications of reverse osmosis system Aq...

Страница 34: ...tonia www pro aquaphor com International 372 356 2204 21 Skype aquaphor market pro e mail market pro aquaphor com AQUAPHOR PROFESSIONAL WATER TREATMENT Dimensions specifications of reverse osmosis sys...

Страница 35: ...e air d Flushing valve is switch on Check the operation of the pump after flushing 4 Very loud pump opera tion sound when pres sure grow up a Control block or element of posting valve Check and replac...

Страница 36: ...han 1 the tank is filled by 1 2 2 3 of the flushing solution Also you must have T branches and locking valves on the line of the permeate product and concentrate with outputs for flexible hoses not in...

Страница 37: ...raining the permeate to the drain for at least 15 min control the TDS parameter shown on the TDS meter q If all indicators of devices are normal switch the valves of permeate line into operation posit...

Страница 38: ...are not more than 3 months from the beginning of operation Lifetime of membrane is 1 year from the beginning of operation Warranty period The warranty period of the RO system is one year from the date...

Страница 39: ...L Tolstoi 2A Sillam e 40231 Estonia www pro aquaphor com International 372 356 2204 21 Skype aquaphor market pro e mail market pro aquaphor com AQUAPHOR PROFESSIONAL WATER TREATMENT 12 CE CERTIFICATE...

Страница 40: ...oi 2A Sillam e 40231 Estonia www pro aquaphor com International 372 356 2204 21 Skype aquaphor market pro e mail market pro aquaphor com AQUAPHOR PROFESSIONAL WATER TREATMENT 13 EC DECLARATION OF CONF...

Отзывы: