background image

Instruction Sheet 

 

 

 

 

 

 

 

 

 

 

 

 

IS-AM09-592 
3/15/2018 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 2 of 2 

 

  

Pump Installation 

 

 

 

 

Cold Water Side Installation 

 

Valve Installation 

Note: Pipe dope and Teflon tape are not required for any of the valve threads. 

The valve is normally installed at the faucet that is furthest away from the hot water heater. If there are separate hot water branches in the residence, 
additional valves may be required.  

1) 

Close both the hot and cold angle stop valves under the sink. 

Fig. 1.

 

2) 

Open both the hot and cold water faucets to relieve the water pressure.  

3) 

Disconnect the riser pipes or hoses from the angle stop valves. Place a pan or rag below the connections to catch any water that may leak 
from the risers. 

Fig. 2. 

 

4) 

Attach the cold water riser to the 3/8” thread on the tee.  

5) 

Install the tee from the kit to the cold water angle stop valve using the 3/8” nut on the tee. 

Fig. 3. 

6) 

Attach the ½” hose from the kit to the ½” connection on the tee. 

Fig. 4.

 

7) 

Attach the Flash valve to the hot water angle stop valve using the 3/8” nut on the Flash valve. 

8) 

Attach the hot water riser to the 3/8” thread on the Flash valve. 

 

9) 

Attach the ½” hose from the kit to the ½” connection on the Flash valve.  

Fig. 5. 

10)  Open the hot and cold Close angle to stop valves and purge air from the lines using the faucets.

  

Note: The spacing dimensions between angle stops vary. Position the valve and tee hose connections to suit your system. 

 
 
 
 
 
Fig. 1.                

Fig. 2.                         

Fig. 3.  

 
 
 

 
 
 
 
 
 

Fig. 4.  

 

Fig. 5. 

 

 

 

 

 

 

 

Timer Operation 

The timer will turn the circulator on and off based on the times when hot water is needed. This may only be in the morning or mornings and 
evenings depending on the schedules of the residence.  

 

Mechanical Timer Operation 

The timer will turn the circulator on and off based the times when hot is needed. This may only be in the morning and evenings depending on the 
schedules of the residence. 

 

Setting Instructions 

1) 

To set the current time, rotate the outer ring until the arrow head lines up with the correct time. 

         This is a 24-hour clock so 1 to 12 on the clock indicates 1am to noon and 13 to 24 on the clock indicates 1pm to midnight. 
2) 

To set the time that the pump will operate, move all tabs outward during the time period. Example: To set on at 7:00am and OFF at 10:00am, 
move all of the tabs between 7 and 10 to outward position. 

3) 

By following the instructions in step 2 multiple on-off cycles can be set. 

4) 

The override switch has 3 positions The “I” indicates the pump will run continuously (24 hours a day). The position next to the clock symbol 
indicates the pump will follow the settings of the tabs. The “O” indicates the pump is off (not running). 

 

For Digital Timer models refer to the attached Grasslin Model FM1D14 Instructions.

 

  

Отзывы: