USER MANUAL – aquama
®
compact Atomizer
USER MANUAL – aquama
®
compact Atomizer
7
6
PART 2
SAFETY INSTRUCTIONS
2.1 CAUTION
2.3 ERROR CODES
2.2 REMARKS
• This device has been designed for the use
described. Any other use will exclude aquama
®
from any liability and warranty.
• Do not get the compact Atomizer wet. To clean,
use a damp cloth and dry immediately.
• Do not use this equipment in an environment
containing explosive or flammable gases.
• Keep children and other persons not connected
with the use of the compact Atomizer at least
10 m away.
•
Always use the accessories supplied by an
authorized dealer.
• If you detect air leakage or any other type of
malfunction, stop using the device, disconnect the
gun and contact your dealer.
• Do not attempt to disassemble or repair the unit.
Any tampering will invalidate the warranty.
• Only a qualified adult should handle the equipment.
The aquama
®
compact Atomizer may display various error messages. If any of these codes appear, proceed as
described in the table below:
The PURE compressor does not have a separate tank to store a reserve of pressurized air. It is therefore free of
rust, dirt and moisture. The aquama
®
compact Atomizer equipment does not require regular purging like most
compressors.
The battery has a thermal protection. It is possible that in case of intensive use the battery will heat up and cut off
the power supply. This safety feature temporarily blocks its use during charging and discharging. In this case, let
the battery cool down before using it again.
Before long periods of inactivity, it is recommended to store the battery with a half charge, do not store the battery
without charge.
The battery, when fully charged, allows approximately 12-18 minutes of operation of the PURE equipment.
If you have any questions, contact aquama
®
by telephone on +41 21 807 17 37 (head office in Switzerland)
or the representative for your country, list available on www.aquama.com
Error code
Description
Check / Solution
E01
Low battery
The electrical current supplied to the equipment is too low. The battery needs
to be recharged or replaced. If the problem persists, contact your dealer.
E02
Overcharge
Turn off the equipment and unplug it from the wall outlet. Wait one minute,
reconnect it to the mains and then switch it on. If the problem persists, contact
your dealer.
E04
Engine
fault
Turn off the equipment and unplug it from the wall outlet. Wait one minute,
reconnect it to the mains and then switch it on. If the problem persists, contact
your dealer.
E08
Controller
fault
Turn off the equipment and unplug it from the wall outlet. Wait one minute,
reconnect it to the mains and then switch it on. If the problem persists, contact
your dealer.
E16
Controller
overheat
The controller has overheated. Let it cool down. If the problem persists,
contact your dealer.
E32
Engine
overheating
The engine has overheated. Let it cool down. If the problem persists, contact
your dealer.