DUO AQUALUX – PAPI004070 – FR – EN – DE – Rev.03.16
10
Adjustment menu:
Code
Function
Setting
Start a manual injection of the pH pump.
When installing, allows starting the pH pump and allows correcting
manually the pH without manipulate the tin.
From 0 to 9,5 mn
Calibrate the pH probe.
Allows by the device to display the pH value found in your swimming pool
with your analysis kit.
+/- 0,5 compared
to the displayed
value
Maintenance / Diagnostic of the failures parameters :
Calibrate the pH probe
: with the standard solutions ph 7 and pH 10 (see §
6.3).
Adjust the volume of the pool.
This device has a proportional regulation to the volume of the pool. For an
optimal efficiency, register in the device, the code corresponding to the
volume of the pool :
Pool volume Code
Pool volume
Code
Pool volume
Code
0 to 1 m
3
01
10 to 15 m
3
11
60 to 70 m
3
21
1 to 2 m
3
02
15 to 20 m
3
12
70 to80 m
3
22
2 to 3 m
3
03
20 to 25 m
3
13
80 to 90 m
3
23
3 to 4 m
3
04
25 to 30 m
3
14
90 to 100m
3
24
4 to 5 m
3
05
30 to 35 m
3
15
100 to 110m
3
25
5 to 6 m
3
06
35 to 40 m
3
16
110 to 120 m
3
26
6 to 7 m
3
07
40 to 45 m
3
17
120 to 130 m
3
27
7 to 8 m
3
08
45 to 50 m
3
18
130 to 140 m
3
28
8 to 9 m
3
09
50 to 55 m
3
19
140 to 150 m
3
29
9 to 10 m
3
10
55 to 60 m
3
20
150 to 160 m
3
30
From 5 to
160 m
3
Choose the type of corrective agent (by default : acid).
Allows modifying the pH corrective mode between acid (make rise the pH
up) or basic (make fall down the pH).
Acid (pH-)
Basic (pH+)
Adjust the pH instruction (7,2 by default).
Allows adjusting the pH value to maintain in the swimming pool.
From 6.8 to 7.6
DISPLAY
pH reading
Flashes
3
V
Select wished
instruction
C
7.2
7.2
MA
V
C
To go out of the menu and return to the normal display
3s
On/Off
3s
Menu
SE
V
MA
Ad
SE
CP
Co
CA