INSTALLATION OF LONG REACH FAUCET 

 
NOTE:  This system includes a standard sink top long reach faucet without an air-gap.  In localities where 

plumbing codes require installation of an air-gap, contact the distributor to obtain an air-gap faucet. 

 
It is recommended that the system representative be consulted for proper tools, techniques and other assistance 
in performing the following procedure. 
The units manufacturer accepts no responsibility for sink top damage resulting from this installation. 
 
SAFETY GLASSES should be worn to protect your eyes while drilling the faucet hole. 
 
1.

 

For best results a 

½

” carbide tipped masonry drill bit should be used to drill the sink hole for the long 

reach faucet. 
 

2.

 

Carefully select the faucet location confirming it will have a neat water fall pattern and that the faucet 
stud will be accessible from below once the hole is completed. 

 
NOTE:  If the faucet stud will not be long enough, an extension is available from your distributor. 
 
3.

 

PORCELAIN SINKS:  Before starting the drill motor, apply firm downward pressure on the drill bit 
until a crunching occurs.  This will help keep the drill bit from walking when starting the hole. 
 

4.

 

STAINLESS STEEL SINKS:  Before using the 

½

” carbide drill bit, an indent should be made with a 

center punch to keep the drill bit from walking.  A small pilot hole will cause excessive wear on the bit 
and progress will be slow. 

 
5.

 

Keep steady firm downward pressure while drilling the hole.  Too little during the start of the hole will 
cause excessive wear on the bit and progress will be slow. 

 
6.

 

Once the hole is completed, immediately clean the area of metal chips and roughness around the hole.  
Metal chips will stain porcelain sinks. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание AQLXC-5RO

Страница 1: ...Aqualux 5 Stage Reverse Osmosis System Operating Manual Aqualux 5 Stage System Aqualux 5 Stage with Booster Pump SKU AQLXC 5RO SKU AQLXC 5RO BP Aqualux 5 Stage with Permeate Pump SKU AQLXC 5RO PP...

Страница 2: ...500 ppm Maximum Total Dissolved Solid TFC Membrane 2500 ppm 4 pH Range CTA Membrane 5 0 to 8 0 TFC Membrane 3 0 to 11 0 5 The system must be connected to COLD water supply only 6 Do not allow unit to...

Страница 3: ...to reduce chlorine In systems with TFC membrane chlorine will damage membrane C The Reverse Osmosis Membrane which is a semi permeable membrane and is the heart of the system Here the remaining suspe...

Страница 4: ...following guidelines should be considered in making this determination A The REVERSE OSMOSIS HEAD ASSEMBLY will free stand alone or may be mounted against a vertical surface in a position to allow acc...

Страница 5: ...or a few minutes and feel the pipes NOTE Some mixing type faucets may require that the hot water by shut off as well If the cold water shut off valve fails to turn off the water the house water supply...

Страница 6: ...he brackets parallel to one another 4 Make the water connection to the outlet of the saddle valve Should you fail to do this before piercing the tube a small amount of water will escape from outlet un...

Страница 7: ...an any debris in the line caused by installation 8 Turn handle counter clockwise to open valve INSTALLATION OF DRAIN SADDLE 1 The drain saddle should be installed above the trap on the vertical or hor...

Страница 8: ...ing it will have a neat water fall pattern and that the faucet stud will be accessible from below once the hole is completed NOTE If the faucet stud will not be long enough an extension is available f...

Страница 9: ...or intermittent water flow or lifted up into a locking position for continuous flow MOUNTING THE REVERSE OSMOSIS HEAD ASSEMBLY 1 Using the bracket as a template mark the screw location at the desired...

Страница 10: ...tom the end of the tubing completely into the brass fitting and tighten with a wrench FITTING WHITE PLASTIC SLEEVE BRASS INSERT COMPRESSION NUT PLASTIC TUBING PLASTIC COMPRESSION FITTINGS To complete...

Страница 11: ...protruding collet with your fingers or 3 8 wrench The gripping mechanism will release and the tubing may be withdrawn NOTE If the quick connect fitting slightly weeps water after connecting Remove th...

Страница 12: ...arbon filter This process prepares the system to produce quality water NOTE The first few tanks of water may have very small air bubbles in the processed water It will clear itself with normal use or...

Страница 13: ...o drain water Clogged brine restrictor Replace brine restrictor Leaking drain assembly or leak Misalignment of hole in drain saddle Realign drain saddle Leaking from air gap opening in faucet Hole or...