AQUALUX AQLXC-5RO Скачать руководство пользователя страница 12

 

 
 
 

START-UP PROCEDURE

 

 

1.

 

Check to see all connections are made. 
 

2.

 

Check that all of the pre-filter and postfilter housings are secure. 

 
3.

 

Slowly turn on the water by turning the needle valve counterclockwise. 

 
4.

 

The valve handle on top of the tank should be in the open position, parallel to the valve body. 

 
5.

 

The black handle of the long reach faucet should be perpendicular to the spigot (closed). 

 
6.

 

Check for leaks. 

 
7.

 

The reverse osmosis drinking water system processes drinking water at a slow rate and may require 6 to 
8 hours before water is readily available from the long reach faucet on a continual basis.  It will take 
longer if also connected to a refrigerator ice maker. 

 

CAUTION FOR YOUR SAFETY BEFORE USING THE WATER FROM YOUR UNIT READ THE 

FOLLOWING INSTRUCTIONS 

 

DO NOT

 use the first tank of water.  Drain the first full tank of water to the drain in order to purge entrapped 

air from the system and rinse down the new carbon filter.  This process prepares the system to produce quality 
water. 
 
NOTE:  The first few tanks of water may have very small air bubbles in the processed water.  It will clear itself 

with normal use or you may drain the tank additional times. 

 

N O T I C E

:  THE PERFORMANCE OF YOUR WATER SYSTEM IS AFFECTED BY WATER 

TEMPERATURE AND WATER PRESSURE. 
 
Your water system has been tested to verify that it will reject at least 90% of the total dissolved solids in the tap 
water and produce the required gallons of quality water in a 24 hour period.  These tests were performed at 
standard conditions in which the tap water was at approximately 68 degrees Fahrenheit (20 degrees C) with a 
water pressure of 60 psi.  Actual performance in your home will vary if the water temperature and pressure are 
different from these standards. 
 
At temperatures lower than 68 degrees Fahrenheit the amount of water produced will decrease by about 0.1 
gallons for each degree of temperature less than 68 degrees Fahrenheit. 
 
At pressures lower than 60 psi, the amount of water produced will decrease by about 0.1 gallons for each 1 psi 
lower than 60 psi. 
 
 
 
 
 
 

Содержание AQLXC-5RO

Страница 1: ...Aqualux 5 Stage Reverse Osmosis System Operating Manual Aqualux 5 Stage System Aqualux 5 Stage with Booster Pump SKU AQLXC 5RO SKU AQLXC 5RO BP Aqualux 5 Stage with Permeate Pump SKU AQLXC 5RO PP...

Страница 2: ...500 ppm Maximum Total Dissolved Solid TFC Membrane 2500 ppm 4 pH Range CTA Membrane 5 0 to 8 0 TFC Membrane 3 0 to 11 0 5 The system must be connected to COLD water supply only 6 Do not allow unit to...

Страница 3: ...to reduce chlorine In systems with TFC membrane chlorine will damage membrane C The Reverse Osmosis Membrane which is a semi permeable membrane and is the heart of the system Here the remaining suspe...

Страница 4: ...following guidelines should be considered in making this determination A The REVERSE OSMOSIS HEAD ASSEMBLY will free stand alone or may be mounted against a vertical surface in a position to allow acc...

Страница 5: ...or a few minutes and feel the pipes NOTE Some mixing type faucets may require that the hot water by shut off as well If the cold water shut off valve fails to turn off the water the house water supply...

Страница 6: ...he brackets parallel to one another 4 Make the water connection to the outlet of the saddle valve Should you fail to do this before piercing the tube a small amount of water will escape from outlet un...

Страница 7: ...an any debris in the line caused by installation 8 Turn handle counter clockwise to open valve INSTALLATION OF DRAIN SADDLE 1 The drain saddle should be installed above the trap on the vertical or hor...

Страница 8: ...ing it will have a neat water fall pattern and that the faucet stud will be accessible from below once the hole is completed NOTE If the faucet stud will not be long enough an extension is available f...

Страница 9: ...or intermittent water flow or lifted up into a locking position for continuous flow MOUNTING THE REVERSE OSMOSIS HEAD ASSEMBLY 1 Using the bracket as a template mark the screw location at the desired...

Страница 10: ...tom the end of the tubing completely into the brass fitting and tighten with a wrench FITTING WHITE PLASTIC SLEEVE BRASS INSERT COMPRESSION NUT PLASTIC TUBING PLASTIC COMPRESSION FITTINGS To complete...

Страница 11: ...protruding collet with your fingers or 3 8 wrench The gripping mechanism will release and the tubing may be withdrawn NOTE If the quick connect fitting slightly weeps water after connecting Remove th...

Страница 12: ...arbon filter This process prepares the system to produce quality water NOTE The first few tanks of water may have very small air bubbles in the processed water It will clear itself with normal use or...

Страница 13: ...o drain water Clogged brine restrictor Replace brine restrictor Leaking drain assembly or leak Misalignment of hole in drain saddle Realign drain saddle Leaking from air gap opening in faucet Hole or...

Страница 14: ...OF ALL OTHER WARRANTIES EXPRESSED OF IMPLIED INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE YOUR REVERSE OSMOSIS UNIT IS BACKED BY A TRADITION OF QUALITY AND SERVICE BEHIND THIS PRODUCT ARE...