AQUALUX AQLXC-5RO Скачать руководство пользователя страница 2

 
 
 

 

FACTORY PREPARATION 

 
This reverse osmosis unit is thoroughly tested before shipment.  Test procedures include: 
 
1.

 

Quality test of the product water produced to assure that minimum standards of impurity rejection are 
met. 

 
2.

 

Test of all components to assure correct function. 

 
3.

 

Flow rate measurement to assure that efficiency specifications are met. 

 
 

WARNING 

 
The feed water supply must comply with the following conditions for the warranty to remain valid. 
 
1.

 

Temperature Range – 40 degrees Fahrenheit to 85 degrees Fahrenheit 

 
2.

 

Water Pressure – 40 psi to 70 psi 

 
3.

 

Maximum Total Dissolved Solid CTA Membrane 1500 ppm 
Maximum Total Dissolved Solid TFC Membrane 2500 ppm 
 

4.

 

pH Range 
CTA Membrane 5.0 to 8.0 
TFC Membrane 3.0 to 11.0 
 

5.

 

The system must be connected to COLD water supply only. 

 
6.

 

Do not allow unit to freeze.  The membrane always contains water and will be destroyed if frozen. 

 
7.

 

Do not use where the water is microbiologically unsafe or with water of unknown quality without 
adequate disinfection before or after the unit. 

 
8.

 

All local plumbing codes are to be followed. 

 
 

PRE INSTALLATION INSPECTION 

 
After opening the shipping container, locate the following items 
1.

 

Reverse Osmosis Head Assembly 

2.

 

Storage Tank 

3.

 

Long reach Faucet with Mounting Hardware 

4.

 

Water Supply Connector (optional) 

5.

 

Drain Saddle (optional) 

6.

 

Four colors of  polyethylene tubing 

7.

 

Storage tank shut off valve with tube connection 

 

Содержание AQLXC-5RO

Страница 1: ...Aqualux 5 Stage Reverse Osmosis System Operating Manual Aqualux 5 Stage System Aqualux 5 Stage with Booster Pump SKU AQLXC 5RO SKU AQLXC 5RO BP Aqualux 5 Stage with Permeate Pump SKU AQLXC 5RO PP...

Страница 2: ...500 ppm Maximum Total Dissolved Solid TFC Membrane 2500 ppm 4 pH Range CTA Membrane 5 0 to 8 0 TFC Membrane 3 0 to 11 0 5 The system must be connected to COLD water supply only 6 Do not allow unit to...

Страница 3: ...to reduce chlorine In systems with TFC membrane chlorine will damage membrane C The Reverse Osmosis Membrane which is a semi permeable membrane and is the heart of the system Here the remaining suspe...

Страница 4: ...following guidelines should be considered in making this determination A The REVERSE OSMOSIS HEAD ASSEMBLY will free stand alone or may be mounted against a vertical surface in a position to allow acc...

Страница 5: ...or a few minutes and feel the pipes NOTE Some mixing type faucets may require that the hot water by shut off as well If the cold water shut off valve fails to turn off the water the house water supply...

Страница 6: ...he brackets parallel to one another 4 Make the water connection to the outlet of the saddle valve Should you fail to do this before piercing the tube a small amount of water will escape from outlet un...

Страница 7: ...an any debris in the line caused by installation 8 Turn handle counter clockwise to open valve INSTALLATION OF DRAIN SADDLE 1 The drain saddle should be installed above the trap on the vertical or hor...

Страница 8: ...ing it will have a neat water fall pattern and that the faucet stud will be accessible from below once the hole is completed NOTE If the faucet stud will not be long enough an extension is available f...

Страница 9: ...or intermittent water flow or lifted up into a locking position for continuous flow MOUNTING THE REVERSE OSMOSIS HEAD ASSEMBLY 1 Using the bracket as a template mark the screw location at the desired...

Страница 10: ...tom the end of the tubing completely into the brass fitting and tighten with a wrench FITTING WHITE PLASTIC SLEEVE BRASS INSERT COMPRESSION NUT PLASTIC TUBING PLASTIC COMPRESSION FITTINGS To complete...

Страница 11: ...protruding collet with your fingers or 3 8 wrench The gripping mechanism will release and the tubing may be withdrawn NOTE If the quick connect fitting slightly weeps water after connecting Remove th...

Страница 12: ...arbon filter This process prepares the system to produce quality water NOTE The first few tanks of water may have very small air bubbles in the processed water It will clear itself with normal use or...

Страница 13: ...o drain water Clogged brine restrictor Replace brine restrictor Leaking drain assembly or leak Misalignment of hole in drain saddle Realign drain saddle Leaking from air gap opening in faucet Hole or...

Страница 14: ...OF ALL OTHER WARRANTIES EXPRESSED OF IMPLIED INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE YOUR REVERSE OSMOSIS UNIT IS BACKED BY A TRADITION OF QUALITY AND SERVICE BEHIND THIS PRODUCT ARE...

Отзывы: