Place the Digital processor on a solid
mounting surface, and place the fixing
feet into suitable positions. Mark then
drill and prepare suitable fixings before
securing the processor to the mounting
surface using the screws provided.
4
Flush through both hot and cold supply pipes.
5
The maximum hot water inlet temperature must be no more than
65˚C.
!
Attach the supply pipes to the Digital
processor, ensuring that the cold and
hot feeds are fitted into the
appropriately marked inlets.
6
DO NOT SOLDER NEAR TO PLASTIC COMPONENTS.
!
Run a pipe from the mixed water outlet on the Digital processor through
to the proposed siting for the bath fill outlet.
7
Suitable non restrictive double check valves (not supplied) MUST
be fitted to the blended outlet pipe in line with current Water
Supply Regulations.
!