Aquatique Thermo
installation instuctions
page 6
Step -by-step instructions
In addition to the guide below it is essential that the written instructions
overleaf are read and understood and that you have all the necessary
components (shown overleaf) before commencing installation. Failure to
install the product in accordance with these instructions may adversely
affect the warranty terms and conditions. Do not undertake any part of this
installation unless you are competent to do so. Prior to starting ensure that
you are familiar with the necessary plumbing regulations required to install
the product correctly and safely.
Aquatique Thermo is supplied with universal fittings.
Please note that the fixing template is supplied as a guide only, we thus
recommend that you assemble the valve and measure the pipe inlet
centres against the template prior to installation.
Carefully cut out the cardboard fixing
template supplied, mark out the inlet supply
holes at 194mm centres.
1
Rear entry pipe work
Set the pipe work to emerge from the wall at right angles.
2
Make good the wall as appropriate. After making good, measure the pipes
and mark the pipe cut off length (19mm-21mm).
3
Remove the mounting ring from the rear of the valve using the 2.5mm
hexagonal key provided. Locate the ring inside the large ring on the template
ensuring the locking screw is in the 6 o’clock position and mark the four
fixing holes.
4
!
!