3.  Features 

                                                                                                                                                                                             

 

a.  DC Twin-rotary inverter compressor of Mitsubishi 
b.  DC Brushless fan motor 
c.  EEV Technology 
d.  Reverse cycle defrosting 
e.  High-efficiency twisted titanium heat exchanger   
f. 

Sensitive and accurate temp control and water temp display 

g.  High pressure and low pressure protection 
h.  Full protection on electrical system 

 
4.  Operating condition and range 

                                                                                                                                                                                             

 

To  provide  you  comfort  and  pleasure,  please  set  swimming  pool  water  temperature  efficiently  and 
economically.

 

The heat pump can work between air -10°C

43°C, and its ideal operation range is between air 15°C ~ 

25°C. 

 
5.  Introduction of different modes 

                                                                                                                                                                                             

 

a.  The heat pump has two modes: Boost and Silence. 
b.  They have different strengths under different conditions. 
 
   

               

 
 
 
 

 
 
 
 

Mode 

Modes 

Strength 

 

Boost mode 

Heating capacity: 20% to 100% capacity 

Intelligent optimization 

Fast heating 

 

Silence mode 

Heating capacity: 20% to 80% capacity 

Sound level: 3dB (A) lower than Boost mode 

Содержание ASC 110

Страница 1: ...Mar 2021 USER MANUAL ...

Страница 2: ...ameter 6 7 Dimension 7 D Installation Guidance 7 1 Installation reminder 8 2 Wiring 10 3 Electric wiring diagram 10 4 References for protecting devices and cable specification 11 E Operation Guidance 11 1 Key function 11 2 Operation instruction 11 F Testing 13 1 Inspect heat pump before use 13 2 Leakage detection notice and method 13 3 Trial 14 G Maintenance 14 H Trouble Shooting for Common Faults...

Страница 3: ...300 383 815 A Foreword Thank you for choosing our inverter pool heat pump which is designed for more silent and energy saving user experience It is an ideal way for green pool heating We hope you ll enjoy using our heat pumps Thank you ...

Страница 4: ...s attention to a procedure practice or the like which if not correctly performed or adhered to could result in personal injury or injury to a third party These signs are rare but are extremely important a Keep the heat pump away from fire source b It must be placed in well ventilated area indoor or closed area is not allowed c Repair and disposal must be carried out by trained service personnel d ...

Страница 5: ...even stopped h Don t use or stock combustible gas or liquid such as thinners paint and fuel to avoid fire i In order to optimize the heating effect please install heat preservation insulation on pipes between swimming pool and the heat pump and please use a recommended cover on the swimming pool j Connecting pipes of the swimming pool and the heat pump should be 10m 3 Safety a Please keep the main...

Страница 6: ...1300 383 815 C About Your Heat Pump 1 Transportation a Always keep upright b Do not lift the water union Otherwise the titanium heat exchanger inside the heat pump may be damaged 2 Accessories Connection of the condensate drainage kit ...

Страница 7: ...4 Operating condition and range To provide you comfort and pleasure please set swimming pool water temperature efficiently and economically The heat pump can work between air 10 C 43 C and its ideal operation range is between air 15 C 25 C 5 Introduction of different modes a The heat pump has two modes Boost and Silence b They have different strengths under different conditions Mode Modes Strength...

Страница 8: ...V 1PH 400V 3ph Rated input power kW 0 14 1 12 0 19 1 38 0 22 1 63 0 26 1 82 0 32 2 51 0 38 2 92 0 5 3 84 0 65 4 84 Rated input current A 0 63 4 83 0 83 5 98 0 96 7 09 1 13 7 83 1 39 10 9 1 65 12 7 2 17 16 7 0 95 7 01 Power cord mm 3X1 5 3X2 5 3X2 5 3X2 5 3X4 3X4 3X6 5X2 5 Sound level at 10m dB A 16 5 26 0 16 8 26 1 16 6 27 9 20 1 28 7 21 1 31 8 18 9 32 2 21 5 32 9 20 6 32 6 Advised water flux m h ...

Страница 9: ...t is subject to adjustment periodically for improvement without further notice D Installation Guidance A B C D E F G H ASC 70 410 645 390 430 890 250 75 657 ASC 90 410 645 390 430 890 250 75 657 ASC 110 410 645 390 430 890 290 75 657 ASC 130 410 645 390 430 890 280 75 657 ASC 170 410 710 390 430 1060 320 75 657 ASC 210 410 710 390 430 1060 390 75 757 ASC 280 410 710 390 430 1060 640 75 957 ASC 350...

Страница 10: ... themselves otherwise the heat pump might be damaged and risky for users safety a Location and clearances The inverter pool heat pump should be installed in a good ventilation place For 17kw and below models For 21kw and above models b Water pipe connection The inlet and outlet water unions can t stand the weight of soft pipes The heat pump must be connected by hard pipes ...

Страница 11: ...cal installation diagram 1 The frame must be fixed by bolts M10 to concrete foundation or brackets The concrete foundation must be solid and fastened the bracket must be strong enough and antirust treated 2 Please don t stack substances that will block air flow near inlet or outlet area and there is no barrier within 50cm behind the main machine or the efficiency of the heat pump will be reduced o...

Страница 12: ...products b Earth the machine well c Wiring must be handled by a professional technician according to the circuit diagram d Set leakage protector according to the local code for wiring leakage operating current 30mA e The layout of power cable and signal cable should be orderly and not affecting each other 3 Electric wiring diagram a For power supply 230V 50Hz b For power supply 400V 50Hz Note 1 Mu...

Страница 13: ... C 4 Auto mode 12 40 C 1 Boost 2 Silence Temperature Setting Attention i The controller has power down memory function ii The buttons will turn dark when it s locked 2 Operation instruction a Screen Lock 1 Press for 3 seconds to lock or unlock the screen 2 Automatic Lock Period 30 seconds if no operation MODEL ASC 70 ASC 90 ASC 110 ASC 130 ASC 170 ASC 210 ASC 280 ASC 350S Breaker Rated Current A 9...

Страница 14: ...ress to switch among boost mode silence mode Default mode boost Please choose boost mode for initial heating e Wi Fi When the screen is on press for 3 seconds after flashing enter Wi Fi connection Connect Wi Fi on mobile phone and input password then control equipment by Wi Fi When APP connects Wi Fi successfully lights on f Defrosting 1 Automatic defrosting When machine is auto defrosting will fl...

Страница 15: ...seconds to switch the display between degrees Celsius and degrees Fahrenheit Attention The controller has power down memory function F Testing 1 Inspect heat pump before use a The ventilating device and outlets are operating adequately and are not obstructed b It s prohibited to install refrigeration pipe or components in corrosive environment c Inspect the electric wiring on basis of the electric...

Страница 16: ...the compressor when starting the machine and it will stop running 1 minute later than the compressor when power off the machine d After the swimming pool heat pump start up please kindly checking for any abnormal noise from the machine G Maintenance 1 In winter season when you don t swim a Cut off power supply to prevent any machine damage b Drain water clear of the machine c Cover the machine bod...

Страница 17: ...s on special maintenance requirements for swimming pool heat pump with R32 gas Please refer to the technical service manual for detailed maintenance operation f Vacuumize completely before welding Welding can only be carried out by professional personnel in service center 2 Failure solution and code Failure Reason Solution Heat pump doesn t run No power Wait until the power recovers Power switch i...

Страница 18: ...f refrigerant gas is leaking check the connection of the sensor EA Evaporator overheat protection only at cooling mode Evaporator Wait for cooldown Eb Ambient temperature too high or too low protection Ambient environment Wait for the environment back to application range Ed Anti freezing reminder Not failure Wait for recover P0 Controller communication failure Controller Check the controller conn...

Страница 19: ...ompressor inverter board Check the compressor and or inverter board connection F5 Inverter board over current protection Inverter board Check the connection inverter board PCB F6 Inverter board overheat protection Inverter board Wait for recover if it shows frequently check the inverter board current F7 Current protection Inverter board Restart the heat pump If it shows frequently check the invert...

Страница 20: ...ater Pump Control Connection Customer remote control switch connector Breaker fuse Customer prepare Earthing Power Supply 230V 50Hz Water pump 230V voltage 500W capacity Water Pump Breaker fuse Customer prepare Power Supply 230V 50Hz Earthing Powercord ...

Страница 21: ...383 815 Customer remote control switch connector Water pump 230V voltage 500W capacity Breaker fuse Customer prepare Earthing Power Supply 230V 50Hz Water Pump Breaker fuse Customer prepare Power Supply 230V 50Hz Earthing Contactor Powercord ...

Страница 22: ... 1300 383 815 Customer remote control switch connector Water pump 400V voltage Breaker fuse Customer prepare Earthing Power Supply 230V 50Hz Water Pump Breaker fuse Customer prepare Power Supply 400V 50Hz Earthing Contactor Power cord ...

Страница 23: ...ontrol and timer connection 1 Water pump timer 2 Water pump wiring of Heat Pump Note The installer should connect 1 parallel with 2 as above picture To start the water pump condition 1 or 2 is connected To stop the water pump both 1 and 2 should be disconnected ...

Страница 24: ...22 hello aquaheataustralia com au 1300 383 815 J Wi Fi Operation ...

Страница 25: ...23 hello aquaheataustralia com au 1300 383 815 ...

Страница 26: ...24 hello aquaheataustralia com au 1300 383 815 ...

Страница 27: ...25 hello aquaheataustralia com au 1300 383 815 ...

Страница 28: ...26 hello aquaheataustralia com au 1300 383 815 ...

Страница 29: ...27 hello aquaheataustralia com au 1300 383 815 ...

Страница 30: ...chnical support PRODUCT INFORMATION Serial Number PERFORMANCE INFORMATION Pool size m3 Setting point C Water flow m3 h Pool cover Yes No Installation distance Cold air outlet Yes No Front cm 2m Back cm 2m Right cm 2m Left cm 2m C PARAMETERS C0 C1 C2 C3 C4 C5 C6 C9 C10 C11 We ll be appreciated if you could provide more details for our analysis Installation date Signature ...

Страница 31: ... in flow switch or E6 Error will be displayed indicating not enough flow detected Recommended procedure a Fully open all valves including the by pass and switch the unit on to max temp b If Error E3 is displayed slowly close by pass valve until unit initiates c Wait 3 4 minutes until heat pump is at 100 capacity d Check inlet and outlet temperature through on screen controller running status check...