Aquaguard AGWAV20 Скачать руководство пользователя страница 12

Installation Preperation

The 

 

system cell MUST

 

be installed horizontally, with the ports down, as the last piece of pool 

equipment in line, on the return to the pool, a

er the heater. (See illustra

on 1 on next page) The 

design of the cell forms a natural gas trap.  Even though the 

 

system

 

has an internal 

ow sensor, 

this installa

on provides a secondary safety feature to prevent gas build-up within the system.  

Note:

  

The inlet is labeled on the cell housing with an arrow poin

ng up.  The cell housing should be located 6 

inches above the height of plumbing: in the event there is no heater, the cell should be located above 

the height of the 

lter inlet and outlets.  Any standard PVC cement may be used.  Always use PVC 

cleaner to prep all glue joints. Allow adequate drying 

me before turning on the pump. All of the 

fi�

ngs 

are 2 inch PVC, and if necessary can be reduced to 1½ inch PVC. The cell has a 10 foot power cord, and 

cannot be modi

ed; use precau

on to place the cell housing within reach of the

 

Control Center. 

 

 

The 

 

Control Center

 

is shipped wired for 220V

. The control center can be converted to

 

120V in the 

eld by a pool professional or cer

�fi

ed electrician; a wiring diagram for making the conversion in 

included with each

 

system.  Ques

ons on this process should be directed to SGS tech support at

 

1-866-972-7258; opera

ng hours for speaking to a technician at the factory are 7:00 AM to 3:00 PM 

Arizona 

me, Monday through Friday.   

 

The 

 

system is designed to power

 

on ONLY

 

when the primary pump is opera

ng and should be 

wired to the load side of the 

me clock

. It must be grounded with an 8AWG bonding wire from the lug 

(see illustra

on #2 on page 15 ) on the bo

om of the Control Center to a grounding rod (this is 

necessary to protect the integrity of the electronic systems).  

Note:  systems are not 

recommended to be installed on pools using a stainless steel liner or stainless steel plumbing. 

 

 

LOAD

LINE

110/220VAC

POWER 

SOURCE

6” VERTICAL

CONTROL

CENTER

POOL

RETURN

SPA

RETURN

FROM

POOL

FROM

SPA

12

Содержание AGWAV20

Страница 1: ...OWNER S MANUAL MODELS AGWAV20 20 000 Gallon System AGWAV40 40 000 Gallon System...

Страница 2: ...equipment failures resulting from the failure to maintain pool water chemistry in accordance with guidelines set forth in the Owner s Manual will void the warranty Customer releases SGS and holds SGS...

Страница 3: ...m Sizing 6 How the AquaGuard Chlorinator Works 7 Water Preperations and Tips on Water Chemistry 7 Salt When and How to Add It 9 Salt Convertion Table 10 Chlorinator Installation 11 Installation Preper...

Страница 4: ...an if you cannot verify the receptacle is protected by a GFCI 4 Do not bury cord Locate cord to minimize abuse from lawn mowers hedge trimmers and other equipment 5 WARNING To reduce the risk of elect...

Страница 5: ...not in any way interfere with this system which has been designed for your protec on CHEMICAL USE HAZARD To avoid personal injury when working with pool chemicals always wear rubber gloves and eye pro...

Страница 6: ...maintain residen al pools up to 40 000 gallons Correct sizing of a chlorine generator is subject to the speci ca ons of each body of water and should be carefully evaluated for best results Where heig...

Страница 7: ...ps on Water Chemistry Pool water that is not maintained properly will cause damage to the electroly c cell and possibly void the warranty of the cell Properly balancing pool water chemistry is the mos...

Страница 8: ...own in the manufacturer s instruc ons to reach the 80 100 PPM range 1 5 lbs of sodium bicarbonate raises 10 000 gallons of pool water by 10 PPM To lower the total alkalinity use muria c acid The acid...

Страница 9: ...page 17 and Troubleshooting sec on for instruc ons on what to do when the system goes into service mode We recommend using pool salt which can be purchased at pool and hardware stores Avoid using sal...

Страница 10: ...60 600 640 680 720 760 800 1800 147 182 220 258 293 330 367 403 440 477 513 550 587 523 660 697 733 2000 133 166 200 234 267 300 333 367 400 433 467 500 533 567 600 633 667 2200 120 150 180 210 240 27...

Страница 11: ...cid Replacement Device 1 Owner s Manual 1 Wiring Conversion Literature LOCATED ON BOX The following tools will be required to install the system Screwdriver Level Hacksaw or PVC cu er Wire Stripping T...

Страница 12: ...t power cord and cannot be modi ed use precau on to place the cell housing within reach of the Control Center The Control Center is shipped wiredfor 220V The control center can be converted to 120V in...

Страница 13: ...e head of the pins in the keyhole slots on the wall bracket and allow the unit to hang freely Your Control Center is now mounted 5 Connect 8AWG bonding wire not included between the grounding rod and...

Страница 14: ...cause possible cell damage and allow the cell to be removed for cleaning when necessary Start up Procedures 1 Balance your water chemistry according to the Water Chemistry Parameters shown on page 8...

Страница 15: ...the maintenance of calcium bridging between the cell blades The clear cell housing makes the monitoring of chlorine produc on and scale build up easy and visually accessible Control Center Func ons 1...

Страница 16: ...MODE should be used to o set out of the ordinary condi ons unusual weather or extremely high bather load Unlike other chlorinators the system is able to produce chlorine at all se ngs on the Sani zer...

Страница 17: ...BE ABLE TO REMOVE THE CELL FROM THE CELL HOUSING HOW TO CLEAN THE CELL 1 Remove the cell cap the large black cap at the end of the clear cell housing by turning it counter clock wise 2 Gently pull th...

Страница 18: ...g to your pool professional s recommenda ons 80 100 PPM APSP Standard 3 Stabilizer Cyanuric Acid Maintain ideal range of 20 30 PPM Follow your pool professional s recommenda ons 4 Calcium Hardness If...

Страница 19: ...PM System Status light is ashing service light is yellow solid Increase Salt level by adding salt according to chart on Page 10 High Phosphates Metals High nitrate level Metals present in pool water C...

Страница 20: ...from the power source Have an experienced pool professional or an electrician con rm that the voltage is existent and correct Circuit breaker may be tripped Check the circuit breaker located on the co...

Страница 21: ...Notes 21...

Страница 22: ...22 Notes...

Страница 23: ...23 Notes...

Страница 24: ......

Отзывы: