Aquafog XE-HRSM-2000-EXP Скачать руководство пользователя страница 8

8

Contact Your Sales Representative for Further Assistance.

7.  Poor Quality Fog

 

A.)

 The liquid feed tube (Part #575) may not be properly positioned. The feed tube is located  

 

  behind the blade assembly and should be inserted approximately 1/4" into the slot    

 

  between the motor shaft and the stainless steel face plate. Centered in the slot area and  

 

  aimed slightly downward, free from any rotational contact.

 

B.)

 Liquid not traveling through the fan blades. This can be diagnosed by viewing the back  

 

  of a blade assembly during operation (using a bright flashlight). If system is clogged,    

 

  liquid can be seen spinning out of the slot area between the motor shaft and stainless

 

  steel face plate (Part #573). If confirmed, replace fan blade assembly (Part #571-assy).

 

  Cleaning the internal passageways of a blade assembly is feasible with the aid of some  

 

  speciality tools.

8.  Fan Motor Becomes Excessively Hot

 

The main fan motor normally becomes very hot to the touch. However, if it gets so hot that it  

 

begins to smell or smoke or the power cord becomes hot, discontinue operation and consult  

 

an electrician to properly evaluate the problem.

9.  Electrical Breaker Tripping

 

If the electrical breaker trips off, there is an overload in the system and there may be a serious  

 

motor problem. Turn off all other devices connected to the same circuit. If the breaker continues  

 

to trip, the motor is probably in need of repair. Consult an electrician for evaluation.

10. Fan and/or Motor Vibration

 

A.)

 

If the fan unit begins vibrating severely, first be sure the blade assembly is fully engaged  

 

  and securely tightened on the motor shaft. Next, inspect the blade assembly, particularly  

 

  the ends of the blades. Look for wear or cracks - replace as necessary. Look for deposits  

 

  of calcium or minerals - clean and remove mineral deposits and/or calcium.

 

B.)

 If the vibration seems to be coming from the motor, first check that the motor mounting  

 

  hardware is securely tightened. If hardware is secure, remove the blade assembly and  

 

  operate the motor without the blade. If vibration continues, the motor has a serious    

 

  mechanical problem and probably needs to be replaced.

11. Plumbing Leaks

 

Un-thread fittings and clean both the male and female threads. Apply new thread tape    

 

(approximately 2-3 wraps) and reconnect. If a tube fitting is leaking, tighten the cap - no    

 

more than 1 turn past finger tightened. If the leak persists, replace the tube fitting insert.

t

roubleShootinG

 

(

Cont

.)

BEFORE INSPECTION AND /OR SERVICE,

DISCONNECT AND LOCK OUT POWER SOURCE.

WARNING

Содержание XE-HRSM-2000-EXP

Страница 1: ...ead Understand Retain for Future Reference XE MOBILE ATOMIZER USER S MANUAL AND OPERATING INSTRUCTIONS OPERATOR S MANUAL UL and CSA Electrical Components NOTICE MODEL XE HRSM 2000 EXP ON OFF Rear Feed...

Страница 2: ...OR SERIOUS INJURY WARNING INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH IF NOT AVOIDED COULD RESULT IN DEATH OR SERIOUS INJURY CAUTION INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH IF NOT AVO...

Страница 3: ...ll fasteners at frequent intervals for proper tightness MOTORS ELECTRICAL EQUIPMENT AND CONTROLS CAN CAUSE ELECTRICAL ARCS THAT WILL IGNITE FLAMMABLE LIQUID OR GAS NEVER OPERATE OR REPAIR IN OR NEAR F...

Страница 4: ...TENSION CORD IS NOT RECOMMENDED IF NECESSARY REFER TO FIG 12 NOTICE Grounded and suitable for hazardous duty locations Unit Preparation EXTENSION CORD SPECIFICATIONS FOR SINGLE FAN USE ONLY AWG Americ...

Страница 5: ...Liquid Supply Hose Connection Liquid Storage Atomized Liquid 449 20A Dedicated Power Supply The volume of fog can be regulated by adjusting the Flow Control Valve See Fig 2 Particle size is smaller dr...

Страница 6: ...n on the unit and listen for any possible abnormalities such as the blades rubbing against the venturi Make re adjustments if necessary Evaluatefogqualitybyadjustingtheoutputusingtheflowcontrolvalve S...

Страница 7: ...pump remove the inline strainer cap Part 71 and turn the system ON for a few seconds Replace cap and try operating unit again B If pump is receiving electricity but there is no fog check for sediment...

Страница 8: ...the electrical breaker trips off there is an overload in the system and there may be a serious motor problem Turn off all other devices connected to the same circuit If the breaker continues to trip...

Страница 9: ...lt SST 8 288 1 8 NPT F elbow 1 294 1 8 NPT M x 3 8 tube fitting 1 349 5 16 brass rod 1 391 Top pivot plate 1 392 Bottom pivot plate 1 395 5 16 nylon lock nut 2 400 047 XE Faceplate screw SST 8 403 Bra...

Страница 10: ...plate Rear of Housing 16 52 600 L 117 54 20 49 32 32 20 600 R 10 Top of Tank Power Cord 58 56 58 57 56 57 116 391 392 56 517 395 479 Side view of motor 458 459 460 452 454 458 457 453 10 2002 10 2002...

Страница 11: ...14 3 455 290 298 295 REA D UNDER ST AND NOTICE WAR NING MA INT AIN A FU LL TANK TO RE TAIN EX PL OS ION PR OO F FE ATUR ES OP ER AT E ON LY WH EN TA NK IS FIL LE D AN D UN IT IS CO NN EC TE D TO A RE...

Страница 12: ...4 20 finish nut SST 2 288 1 8 NPT elbow 1 290 1 4 NPT street tee 1 294 1 8 NPT F x 3 8 tube fitting 1 295 1 4 NPT M x 1 4 tube fitting 1 297 1 4 NPT F x 3 8 tube fitting 1 298 1 2 NPT M x 1 4 NPT F bu...

Страница 13: ...r will be required 4 Inspect Blade Assembly Clean the blade assembly about once a year especially if a film of calcium or mineral deposits is visible on the exterior of the blades Remove any build up...

Страница 14: ...ck of maintenance or unauthorized repairs or alterations which affect the machine s performance or reliability LIMITATIONS OF LIABILITY TO THE EXTENT ALLOWABLE UNDER APPLICABLE LAW JAYBIRD MANUFACTURI...

Отзывы: