Aquafog XE-HRSM-2000-EXP Скачать руководство пользователя страница 2

General Safety   . . . . . . . . . . . . . . . . . . . . . . . .
Getting Started  . . . . . . . . . . . . . . . . . . . . . . . . 
Controls and Installation    . . . . . . . . . . . . . . .  
Testing and Operation   . . . . . . . . . . . . . . . . . . 
Troubleshooting    . . . . . . . . . . . . . . . . . . . . 
Aquafog Fan Exploded View   . . . . . . . . . 
HRSM Tank Exploded View   . . . . . . . . . . 
Maintenance   . . . . . . . . . . . . . . . . . . . . . . . . . 
Warranty    . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

PAGE     

3

 4
 5

6

7 - 8

9 - 10

 11 - 12

13
14

S

afety

 G

uidelineS

This manual contains very important information. 

This information will help ensure SAFETY and 

PREVENT EQUIPMENT PROBLEMS. Use these 

symbols to understand safety guidelines.

DANGER

DANGER INDICATES AN 

IMMINENTLY HAZARDOUS 

SITUATION WHICH, IF NOT AVOIDED, WILL RESULT IN 

DEATH OR SERIOUS INJURY.

WARNING INDICATES A 

POTENTIALLY HAZARDOUS 

SITUATION WHICH, IF NOT AVOIDED, COULD RESULT IN 

DEATH OR SERIOUS INJURY.

CAUTION INDICATES A 

POTENTIALLY HAZARDOUS 

SITUATION WHICH, IF NOT AVOIDED, MAY RESULT IN 

MINOR OR MODERATE INJURY.

NOTICE INDICATES IMPORTANT 

INFORMATION, THAT IF NOT 

FOLLOWED, MAY CAUSE DAMAGE TO EQUIPMENT.

t

able

 

of

 C

ontentS

WARNING

CAUTION

NOTICE

Notes

d

eSCription

Aquafog mobile units are intended to condition large  

volumes of air using water or other non-hazardous 

liquids at air temperatures between 31ºF and 145ºF. 

Any other use of these units will void the warranty 

and the manufacturer will not be responsible for 

problems or damages resulting from misuse.

Содержание XE-HRSM-2000-EXP

Страница 1: ...ead Understand Retain for Future Reference XE MOBILE ATOMIZER USER S MANUAL AND OPERATING INSTRUCTIONS OPERATOR S MANUAL UL and CSA Electrical Components NOTICE MODEL XE HRSM 2000 EXP ON OFF Rear Feed...

Страница 2: ...OR SERIOUS INJURY WARNING INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH IF NOT AVOIDED COULD RESULT IN DEATH OR SERIOUS INJURY CAUTION INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH IF NOT AVO...

Страница 3: ...ll fasteners at frequent intervals for proper tightness MOTORS ELECTRICAL EQUIPMENT AND CONTROLS CAN CAUSE ELECTRICAL ARCS THAT WILL IGNITE FLAMMABLE LIQUID OR GAS NEVER OPERATE OR REPAIR IN OR NEAR F...

Страница 4: ...TENSION CORD IS NOT RECOMMENDED IF NECESSARY REFER TO FIG 12 NOTICE Grounded and suitable for hazardous duty locations Unit Preparation EXTENSION CORD SPECIFICATIONS FOR SINGLE FAN USE ONLY AWG Americ...

Страница 5: ...Liquid Supply Hose Connection Liquid Storage Atomized Liquid 449 20A Dedicated Power Supply The volume of fog can be regulated by adjusting the Flow Control Valve See Fig 2 Particle size is smaller dr...

Страница 6: ...n on the unit and listen for any possible abnormalities such as the blades rubbing against the venturi Make re adjustments if necessary Evaluatefogqualitybyadjustingtheoutputusingtheflowcontrolvalve S...

Страница 7: ...pump remove the inline strainer cap Part 71 and turn the system ON for a few seconds Replace cap and try operating unit again B If pump is receiving electricity but there is no fog check for sediment...

Страница 8: ...the electrical breaker trips off there is an overload in the system and there may be a serious motor problem Turn off all other devices connected to the same circuit If the breaker continues to trip...

Страница 9: ...lt SST 8 288 1 8 NPT F elbow 1 294 1 8 NPT M x 3 8 tube fitting 1 349 5 16 brass rod 1 391 Top pivot plate 1 392 Bottom pivot plate 1 395 5 16 nylon lock nut 2 400 047 XE Faceplate screw SST 8 403 Bra...

Страница 10: ...plate Rear of Housing 16 52 600 L 117 54 20 49 32 32 20 600 R 10 Top of Tank Power Cord 58 56 58 57 56 57 116 391 392 56 517 395 479 Side view of motor 458 459 460 452 454 458 457 453 10 2002 10 2002...

Страница 11: ...14 3 455 290 298 295 REA D UNDER ST AND NOTICE WAR NING MA INT AIN A FU LL TANK TO RE TAIN EX PL OS ION PR OO F FE ATUR ES OP ER AT E ON LY WH EN TA NK IS FIL LE D AN D UN IT IS CO NN EC TE D TO A RE...

Страница 12: ...4 20 finish nut SST 2 288 1 8 NPT elbow 1 290 1 4 NPT street tee 1 294 1 8 NPT F x 3 8 tube fitting 1 295 1 4 NPT M x 1 4 tube fitting 1 297 1 4 NPT F x 3 8 tube fitting 1 298 1 2 NPT M x 1 4 NPT F bu...

Страница 13: ...r will be required 4 Inspect Blade Assembly Clean the blade assembly about once a year especially if a film of calcium or mineral deposits is visible on the exterior of the blades Remove any build up...

Страница 14: ...ck of maintenance or unauthorized repairs or alterations which affect the machine s performance or reliability LIMITATIONS OF LIABILITY TO THE EXTENT ALLOWABLE UNDER APPLICABLE LAW JAYBIRD MANUFACTURI...

Отзывы: