Fig. 4

Adjustment Pin

5

Fig. 3

C

ONTROLS

/ F

EATURES

The volume of fog can be regulated by adjusting the 

Flow Control Valve. (See 

Fig. 3

)

Particle size is smaller at lower outputs, so it is 

better to operate the unit at a lower output for 

longer periods of time.

At the base of the plumbing is an in-line strainer with 

a removable cap. Periodically check inside and flush 

any sediment from the screen. (See 

Fig. 3

)

The ORSM is equipped with a four position pivoting 

fogging head with 15º intervals up to 45º. Propelling 

the fog upward allows more time for the particles to 

evaporate, keeping floor areas drier.
When making an adjustment, balance the weight of 

the fogging head off of the pin for easy removal.

(See 

Fig. 4

)

Flow Control/ Strainer/ Pivot 

Inline 

Strainer

Fluid Level Gauge

On/Off

Fan Motor

Key

Hose

Connector

Flow Control 

Valve

Optional Inlet

(See [

*

] below)

On/Off

(Pumps)

*

 

Connect unit's plumbing directly to a metering pump (with 3/8" 

  tube fitting provided). This provides a way to feed chemical 

  concentrate to the ORSM. 

T

ESTING

 

AND

 E

VALUATION

►  

Turn on the unit and listen for any possible abnormalities, such as the blades rubbing against the 

      venturi. Make re-adjustments if necessary.

►  

Evaluate fog quality adjusting the output by using the flow control valve. (See 

Fig. 3

). After starting, it 

      generally takes several seconds for the liquid to reach the atomizing fan. 

BEFORE TESTING FAN MAKE SURE ALL OBJECTS ARE OUT OF THE 

ROTATION PATH OF THE FAN BLADES.HIGH-SPEED WARNING. 

KEEP HANDS 

CLEAR!

 MAKE SURE GUARDS ARE INSTALLED OR UNIT IS OUT OF REACH.

DANGER

CAREFULLY LISTEN FOR UNUSUAL NOISE OR VIBRATION.

CAUTION

►  

For first-time evaluation, fill tank (with water only) about one quarter full.

►  

Connect to power supply. 

►  

BUMP START ORSM and check for proper fan blade rotation (clockwise if looking at front of unit). 

   

      

If incorrect, find rotation connection changes on the motor's electrical schematic.

OFF

ON

Содержание SE-ORSM-1500

Страница 1: ...XE ORSM MODEL o ORSM 1000 o ORSM 1500 Read Understand Retain for Future Reference XE MOBILE ATOMIZER USER S MANUAL AND OPERATING INSTRUCTIONS OPERATOR S MANUAL NOTICE UL and CSA Electrical Components...

Страница 2: ...or problems or damages resulting from misuse SAFETY GUIDELINES This manual contains very important information This information will help ensure SAFETY and PREVENT EQUIPMENT PROBLEMS Use these symbols...

Страница 3: ...w children in the work area 7 Use of an extension cord for the ORSM is not recommended If necessary refer to the A W G chart in the following section or consult a certified electrician 8 Before each u...

Страница 4: ...E ONLY AWG American Wire Gauge Voltage 25 to 50 ft 50 to 100 ft 115 14 AWG 12 AWG 230 16 AWG 14 AWG Fig 12 ELECTRICAL GROUND FAULT RECEPTACLES ARE RECOMMENDED AND MAY BE REQUIRED BY LOCAL AND OR NATIO...

Страница 5: ...See below On Off Pumps Connect unit s plumbing directly to a metering pump with 3 8 tube fitting provided This provides a way to feed chemical concentrate to the ORSM TESTING AND EVALUATION Turn on th...

Страница 6: ...t the bottom of the fan housing See Fig 5 Use a measuring cup and turn on only the feed pump for a 60 second interval while catching the water from the feed tube Multiply ounces of water by 60 and the...

Страница 7: ...rapped air If the problem persists check your pre set flow rate valve refer to page 6 Factory Pre set Flow Valve The ORSM will automatically prime the feed pump but if the pre set flow rate valve is i...

Страница 8: ...l Noise It is normal to hear a slight rattling noise at start up and shut down This is caused by the tip of the liquid feed tube entering the center of the fan blade assembly reservoir 6 Fan Motor Bec...

Страница 9: ...nut SST 4 43 11 16 x 1 1 4 flat washer SST 1 44 Drain tubing 3 45 Liquid tight cord fitting 2 46 Key 1 52 1 4 20 x 3 4 HH bolt SST 4 54 1 4 20 x 3 8 button head cap screw 6 56 5 16 18 x 3 4 HH bolt SS...

Страница 10: ...w of motor Side of top pivot plate Rear of Housing Power supply in from on off switch Power supply out to pump 8 13 14 15 16 52 600 L 117 54 20 344 46 58 56 45 45 43 8 39 44 32 58 57 56 57 116 349 403...

Страница 11: ...60 61 84 45 71 72 65 65 295 295 65 65 84 45 198 67 65 Tank s Wall Inside Tank ORSM TANK EXPLODED VIEW 232 207 86 69 69 75 171 173 143 3 8 tube fitting provided for optional connection to metering pump...

Страница 12: ...1 84 3 4 M socket x 1 2 F NPT Bushing 2 86 6 32 x 1 2 oval slotted screw 6 93 Hose connector gasket 1 94 Hose connector 1 96 Gasket 2 97 Float valve 1 98 Stem 1 99 Float 1 111 Axle SST 1 126 1 4 lock...

Страница 13: ...he blades about once a year or whenever a film of calcium or mineral deposits is visible While cleaning inspect for irregularities or hairline cracks and replace as necessary 5 Storage Protect your mo...

Страница 14: ...ent lack of maintenance or unauthorized repairs or alterations which affect the machine s performance or reliability LIMITATIONS OF LIABILITY TO THE EXTENT ALLOWABLE UNDER APPLICABLE LAW JAYBIRD MANUF...

Отзывы: