background image

13

M

AINTENANCE

1.  Clean Strainers

       The ORSM is equipped with 2 accessible strainers that should be cleaned regularly - the drain 

       strainer (Part #39) in the tank and the inline strainer (Part #71) at the bottom of the flow control 

       valve. Check these strainers regularly and remove any trapped debris.

2.   Flush Out Tank

       The tank should be rinsed regularly, especially if using chemicals. Remove drain plug (Part 

       #351) and, using a garden hose, thoroughly flush tank and pump of any sediment.

3.   Main Motor

       The main motor is a permanently lubricated motor, but occasionally applying some spray oil to 

       external rusty areas of the motor's body can help extend the motor's life.

4.   Inspect Blade Assembly

       Clean the exterior of the blades about once a year or whenever a film of calcium or 

       mineral deposits is visible. While cleaning, inspect for irregularities or hairline cracks and 

       replace as necessary.

5.   Storage

       Protect your mobile Aquafog from winter damage. Expansion due to freezing can burst the 

       fittings or the internal feed pump. If storing unit in below freezing temperatures, be sure all fluid 

       is drained from the tank area. Damage due to freezing is not covered under warranty.

DISCONNECT AND LOCK OUT POWER SOURCE

BEFORE SERVICING

WARNING

E

LECTRICAL

 S

CHEMATICS

115 V

OLT

  

1

 P

HASE

  

60/50

 H

ERTZ

Domestic (USA)/ Foreign

Note: All green wires

go to ground

Denotes Line

Connection

Denotes

Termination

N

mtr

FAN

mtr

PUMPS

SPST

TGS

115 VAC

LINE

SPST

TGS

On

2, 4, 5

1, 3, 8

Brown

Blue

Off

115V

115V

On

Off

240 V

OLT

  

1

 P

HASE

  

50

 H

ERTZ

Foreign

FAN

mtr

mtr

PUMPS

N

240 VAC

LINE

SPST

TGS

On

2, 3, 8

4, 5

Brown

Blue

Off

240V

240V

1

SPST

TGS

On

Off

Содержание SE-ORSM-1500

Страница 1: ...XE ORSM MODEL o ORSM 1000 o ORSM 1500 Read Understand Retain for Future Reference XE MOBILE ATOMIZER USER S MANUAL AND OPERATING INSTRUCTIONS OPERATOR S MANUAL NOTICE UL and CSA Electrical Components...

Страница 2: ...or problems or damages resulting from misuse SAFETY GUIDELINES This manual contains very important information This information will help ensure SAFETY and PREVENT EQUIPMENT PROBLEMS Use these symbols...

Страница 3: ...w children in the work area 7 Use of an extension cord for the ORSM is not recommended If necessary refer to the A W G chart in the following section or consult a certified electrician 8 Before each u...

Страница 4: ...E ONLY AWG American Wire Gauge Voltage 25 to 50 ft 50 to 100 ft 115 14 AWG 12 AWG 230 16 AWG 14 AWG Fig 12 ELECTRICAL GROUND FAULT RECEPTACLES ARE RECOMMENDED AND MAY BE REQUIRED BY LOCAL AND OR NATIO...

Страница 5: ...See below On Off Pumps Connect unit s plumbing directly to a metering pump with 3 8 tube fitting provided This provides a way to feed chemical concentrate to the ORSM TESTING AND EVALUATION Turn on th...

Страница 6: ...t the bottom of the fan housing See Fig 5 Use a measuring cup and turn on only the feed pump for a 60 second interval while catching the water from the feed tube Multiply ounces of water by 60 and the...

Страница 7: ...rapped air If the problem persists check your pre set flow rate valve refer to page 6 Factory Pre set Flow Valve The ORSM will automatically prime the feed pump but if the pre set flow rate valve is i...

Страница 8: ...l Noise It is normal to hear a slight rattling noise at start up and shut down This is caused by the tip of the liquid feed tube entering the center of the fan blade assembly reservoir 6 Fan Motor Bec...

Страница 9: ...nut SST 4 43 11 16 x 1 1 4 flat washer SST 1 44 Drain tubing 3 45 Liquid tight cord fitting 2 46 Key 1 52 1 4 20 x 3 4 HH bolt SST 4 54 1 4 20 x 3 8 button head cap screw 6 56 5 16 18 x 3 4 HH bolt SS...

Страница 10: ...w of motor Side of top pivot plate Rear of Housing Power supply in from on off switch Power supply out to pump 8 13 14 15 16 52 600 L 117 54 20 344 46 58 56 45 45 43 8 39 44 32 58 57 56 57 116 349 403...

Страница 11: ...60 61 84 45 71 72 65 65 295 295 65 65 84 45 198 67 65 Tank s Wall Inside Tank ORSM TANK EXPLODED VIEW 232 207 86 69 69 75 171 173 143 3 8 tube fitting provided for optional connection to metering pump...

Страница 12: ...1 84 3 4 M socket x 1 2 F NPT Bushing 2 86 6 32 x 1 2 oval slotted screw 6 93 Hose connector gasket 1 94 Hose connector 1 96 Gasket 2 97 Float valve 1 98 Stem 1 99 Float 1 111 Axle SST 1 126 1 4 lock...

Страница 13: ...he blades about once a year or whenever a film of calcium or mineral deposits is visible While cleaning inspect for irregularities or hairline cracks and replace as necessary 5 Storage Protect your mo...

Страница 14: ...ent lack of maintenance or unauthorized repairs or alterations which affect the machine s performance or reliability LIMITATIONS OF LIABILITY TO THE EXTENT ALLOWABLE UNDER APPLICABLE LAW JAYBIRD MANUF...

Отзывы: