background image

 

Aquafog and accessories are warranted to the original purchaser 

against defects in material and workmanship under normal use for one 

full year from date of purchase. Any part determined to be defective and 

returned to the manufacturer, shipping cost prepaid, will be repaired or 

replaced at Jaybird Manufacturing, Inc.'s discretion without charge. Proof 

of purchase date and an explanation of the problem or complaint must 

accompany the returned portion of the machine.

 

Jaybird Manufacturing, Inc. reserves the right to verify the legiti-

macy of claimed defects. The provisions of this warranty do not apply to 

damage resulting from direct or indirect misuse, negligence, accident, 

lack of maintenance, or unauthorized repairs or alterations which affect 

the machine's performance or reliability.

 

LIMITATIONS OF LIABILITY. TO THE EXTENT ALLOWABLE UNDER 

APPLICABLE  LAW,  JAYBIRD  MANUFACTURING,  INC.'S  LIABILITY  FOR 

DEATH, INJURIES TO PERSONS OR PROPERTY, OR FOR CONSEQUENTIAL 

OR  INCIDENTAL  DAMAGES  ARISING  FROM  THE  USE  OF  OUR  EQUIP-

MENT IS EXPRESSLY DISCLAIMED. JAYBIRD MANUFACTURING, INC.'S 

LIABILITY  IN  ALL  EVENTS  IS  LIMITED  TO,  AND  SHALL  NOT  EXCEED, 

THE PURCHASE  PRICE PAID. NO OTHER WARRANTY, EXPRESSED OR 

IMPLIED,  IS  AUTHORIZED,  INCLUDING  WARRANTIES  OF  MERCHANT-

ABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

This warranty gives you specific legal rights, and you may also have other 

rights, which vary from state to state.

1

year

O

NE

 Y

EAR

 L

IMITED

 W

ARRANTY

Made in U.S.A.

© 2020  Jaybird Mfg., Inc.

Jaybird Manufacturing, Inc.

135 Summer Lane

Centre Hall, PA  16828

Parts & Service:     1.814.364.1800

Website:           www.jaybird-mfg.com

Содержание HYDRO SS 700

Страница 1: ...HYDRO SS 700 OPERATOR S MANUAL Read Understand Retain for Future Reference NOTICE DIRECT FEED ...

Страница 2: ...Notes Purchase Date Model ID Number Vendor Information ...

Страница 3: ...y Damaged cords increase the risk of electric shock If use of an extension cord is necessary use a heavy gauge 3 wire extension cord with a molded three prong plug Keep hands and all objects from entering the path of the blade Install the Hydro SS 700 at seven 7 foot height or higher for added safety and optimum performance Do not use flammable liquids caustic materials or corrosive materials with...

Страница 4: ...et 1 Service Allen Wrench for Blade Assembly THE HYDRO SS 700 CAN BE AUTOMATED WHEN USED IN CONJUNCTION WITH A CONTROL THE FAN MAY NOT APPEAR POWERED BUT COULD SUDDENLY BEGIN HIGH SPEED ROTATION AS A FUNCTION OF THE PRESET CONTROL WARNING HIGH SPEED ROTATION NEVER OPERATE UNIT WITHOUT THE HOUSING AND SAFETY GUARDS INSTALLED UNPACKING NOTIFICATION GROUND FAULT RECEPTACLES ARE STRONGLY RECOMMENDED A...

Страница 5: ...he unit at the largest most open end and propel the fog towards the opposite end Utilize the pivoting fogging head in order to maximize the unit s performance DO NOT propel the fog into the wind or direction of airflow DO NOT pivot the fogging head to propel fog at a sharp downward angle DO NOT cramp the fan in tight spaces or skinny aisleways DO NOT mount the fan near the ground or underneath tab...

Страница 6: ...le level for monitoring Large Structures Equally space the units within the structure Lower humidity and or cooling requirements can allow for greater distance between fans Usually the maximum distance between fans should be 20 from the side and 35 from the front If the structure has forced ventilation shift the fans closer to the intake end The fans should always be propelling their fog with the ...

Страница 7: ...panel should be mounted in an accessible location for monitoring and adjusting water flow rate Cut 1 4 tubing at the desired location for the flowmeter Connect the flowmeter to the tubing between the Hydro unit and the water supply Use the remaining tubing and hose connector to connect to an available hose bib To remove hose connector apply pressure to the retaining clip while pulling on the tubin...

Страница 8: ...cally check and clean out debris that gets caught in the in line strainer Winterizing Protect your unit from winter damage If storing unit in freezing temperatures be sure all fluid is drained from the unit Fig 5 Blade s Reservoir Area Water Passageway O ring Stainless Face Plate Blade Assy Clip Plunger Water Solenoid from optional control packages Water Solenoid Coil Brass Body Screws Fig 6 3 in ...

Страница 9: ...lubricate motor bearings while manually rotating shaft back and forth until loose 2 If motor smells doesn t start with a direct power supply or shaft will not loosen up replace motor 3 Remove valve and clean If problem reoccurs perform a thorough cleaning inside the flowmeter body 4 Remove strainer cap screen and O ring Flush clean with water 5 Remove the top clip and disassemble the valve s brass...

Страница 10: ... blade assembly securing the motor to rear guard See Fig 8 Cleaning Flowmeter Using a small flat screwdriver remove the retaining key using Slot A by sliding the key out toward the back See Fig 9 Next use the screwdriver in Slot B to pull the retainer cap straight up After the retainer cap is removed be careful not to lose the internal float ball when handling or cleaning the flowmeter A B Screwdr...

Страница 11: ...Guard 400 002 3 Motor 115V 400 110 4 Rear Guard 400 127 5 Blade Assembly 400 128 6 Housing 400 100 7 SST Hanger a 620 8 Water Feed Tube 400 130 9 Pivot Location NA 10 Drain Barb Fitting 400 114 11 Drain Hose 400 089 12 Flowmeter Panel a F 5 13 In Line Strainer 71 14 1 4 Water Tubing W 14 15 Hose Connector W 2 ...

Страница 12: ...or unauthorized repairs or alterations which affect the machine s performance or reliability LIMITATIONS OF LIABILITY TO THE EXTENT ALLOWABLE UNDER APPLICABLE LAW JAYBIRD MANUFACTURING INC S LIABILITY FOR DEATH INJURIES TO PERSONS OR PROPERTY OR FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES ARISING FROM THE USE OF OUR EQUIP MENT IS EXPRESSLY DISCLAIMED JAYBIRD MANUFACTURING INC S LIABILITY IN ALL EVENTS...

Отзывы: