Page - 54
3.8 Initial Cooling Recommendations
The following recommendations will reduce the amount of time required to cool a pool or cold plunge
application.
If unsure of equipment cooling capability, review equipment data plate.
1. Use the heat pump's "POOL/SPA" button to select the "POOL" group.
2. Select 48HR (48 hours) for the "SET TIME".
3. Confirm the mode has been set to "COOL" mode.
4. Set the desired temperature "COOL SETPOINT" for the water.
5. If a circulation pump has been connected to the heat pump, it will automatically activate.
6. Activate Turbo Boost Mode if equipped.
3.9 Service Mode
The heat pump can be set into a service mode where all connected devices including the heat pump can be
deactivated for servicing. While in service mode, connected devices / equipment can be manually activated as
needed.
Enter "Shortcuts" menus, then proceed
IF UNIT IS ASLEEP,
SWIPE TO WAKE UP
A
PRESS MENU
BUTTON
B
USE ARROWS TO
"SHORTCUTS"
C
PRESS "ENTER"
1
USE ARROWS TO MENU
"SERVICE MODE"
2
PRESS ENTER TO EDIT
3
USE ARROWS TO
"ON"
4
ENTER TO SAVE
MENU TO EXIT, PRESS
& HOLD TO STATUS
When service is complete, repeat above
steps setting SERVICE MODE to "OFF".