Page - 57
DEFROST1 SENSOR SHORT
or
DEFROST2 SENSOR SHORT
ISSUE
Shorted defrost sensor.
RESOLUTION
A qualified technician should replace the defrost sensor.
ERROR AT MASTER UNIT
ISSUE
The heat pump is slaved to a master heat pump that is displaying a fault code.
RESOLUTION
The error at the master heat pump must be corrected before the slaved unit will resume operation.
HIGH PRESSURE FAULT
ISSUE
The refrigerant system’s high-pressure switch is showing as open.
RESOLUTION
Heat Only Units
Place heat pump in heating mode and perform the following troubleshooting.
Determine if an insufficient amount of water is being supplied to the equipment.
1. Confirm the filter pump is on.
2. If a multiple-speed filter pump is being used, run filter pump at a higher speed. Do not exceed the
maximum flow rate for the model.
3. Confirm water is not being diverted away from the heat pump.
l
l
Adjusting Water Flow Using ΔT (Delta-T)
4. The water pressure switch may be incorrectly calibrated.
l
Adjusting Water Pressure Switch
HIGH WATER TEMPERATURE
ISSUE
Incoming water temperature has exceeded 110° F (43° C) and the unit has been deactivated. The heat
pump will not operate until the incoming water temperature drops to 100° F (38° C) or lower.
RESOLUTION
1. Determine if a gas heater is sending water directly to the heat pump. This situation would need to be
corrected before continuing.
2. If a solar heater is sending water directly to the heat pump, the water can initially be hotter than 110° F
(43° C). After the water from the solar panel normalizes, the fault will no longer display and the heat pump
will resume as needed.
3. If the
HIGH WATER TEMPERATURE
fault continues to display, the water temperature sensor may
require replacement.
2
-
T
roubl
es
hoot
ing
Содержание Leisure Temp LT1000
Страница 2: ......
Страница 9: ...Page 6 1 3 Dimensions Leisure Temp LT55 Leisure Temp LT400 1 Installation...
Страница 10: ...Page 7 Leisure Temp LT600 Leisure Temp LT700 LT800 1 Installation...
Страница 15: ...Page 12 Leisure Temp LT55 Leisure Temp LT400 and LT600 Leisure Temp LT700 LT800 and LT1000 1 Installation...
Страница 26: ...Page 23 Configure Call Flex Enter Installer Menus then proceed 1 Installation...
Страница 30: ...Page 27 1 Installation...
Страница 33: ...Page 30 1 Installation...
Страница 36: ...Page 33 Configure for 24 Hour Mode Enter Installer Menus then proceed 1 Installation...
Страница 37: ...Page 34 Configure for Scheduled Mode Enter Installer Menus then proceed 1 Installation...
Страница 38: ...Page 35 1 Installation...
Страница 41: ...Page 38 1 Installation...
Страница 43: ...Page 40 1 Installation...
Страница 46: ...Page 43 1 Installation...
Страница 50: ...Page 47 1 Installation...
Страница 53: ...Page 50 1 Installation...
Страница 55: ...Page 52 1 Installation...
Страница 72: ......