Page - 4
Anchoring to Pad
l
Follow all applicable local, state, and national requirements regarding wind load anchoring.
l
The shipping brackets used to secure the heat pump to the pallet are approved mounting (hurricane) brackets.
They should be used to anchor the heat pump to the pad.
l
If needed, contact AquaCal
®
to obtain anchoring kit information. Please have the heat pump model number and
serial number when requesting support.
See "Identifying Model Specifications" on page 26.
1.2 Clearances
l
Proper air circulation is required for the heat pump to operate efficiently. The following diagrams show the
minimum clearances required for the proper operation of the heat pump.
l
Avoid storing chemical containers near the heat pump. The chemicals can cause equipment damage.
l
Avoid placing objects near or on top of the heat pump. This includes shrubbery and lawn furniture. These objects
will reduce performance and efficiency and hinder maintenance access.
(Overhead Clearance)
(Top View)
1.3 Plumbing
1.3.a Plumbing Requirements
NOTICE
Failure to heed the following may result in damage to equipment.
l
Do not use glue on the threaded portion of the equipment’s unions. A glued-in-place union will prevent the
equipment from being properly winterized.
l
The heat pump must receive water flow within the specified minimum ranges under worst-case conditions such as a
fouled water filter.
l
Failure to provide clean filtered water to the heat pump can void product warranty.
l
Water flow exceeding maximum flow rates will negatively affect the total pool filtration performance and may
damage the heat pump. This will not be covered under equipment warranty.
See "Water Flow Rates" on page 9.
l
Install a bypass valve whenever water-flow may exceed maximum rating.
l
See "Bypass Valve Kit (# STK0135)" on page 28.
l
For additional guidance testing water flow rates, please contact AquaCal
®
.
l
A safety enhancing "Over Temperature Alarm" kit is strongly recommended for all spa applications.
See "Over
Temperature Alarm Kit" on page 29.