Page - 3
1 - Installation
WARNING
Failure to heed the following may result in injury or death.
l
Installation of this equipment by anyone other than a qualified installer can result in a safety hazard.
l
The information contained throughout the "Installation" section is intended for use by qualified installation
technicians familiar with the swimming Pool / Spa safety standards.
NOTICE
Failure to heed the following may result in damage to equipment.
l
Failure to protect equipment against corrosive conditions will adversely affect the life of the equipment and will
void equipment warranty.
1.1 Positioning Equipment
NOTICE
Failure to heed the following may result in damage to equipment.
l
Do not install equipment inside of a building.
Outdoor Use Only
Do not install equipment inside of a room or building.
l
Heat Pumps require unobstructed air flow for proper operation. Heat Pumps should never be installed indoors or
in a location where air flow is restricted.
See "Clearances" on page 4.
Controlling Irrigation and Rainwater Runoff
l
Irrigation water may damage heat pump components. Direct irrigation water away from the heat pump.
l
The heat pump will withstand normal rainfall. Do not allow a roof slope to direct rainwater onto the heat pump.
Have a gutter installed on the roof edge to direct this water away from the heat pump. Or install the heat pump in
another location.
Planning for Condensation
The heat pump can produce a large amount of condensation. The amount of water depends on air temperature
and humidity.
l
Install the heat pump with enough height to allow for water drainage.
l
Plan for water drainage as needed.
n
See "Condensation Drain Kit (# STK0202)" on page 28.
Mounting Pad Requirements
l
The heat pump's base must be installed on a flat and level surface that completely supports the
entire base.
l
Build the heat pump pad out of concrete or other code-approved material.
l
Confirm the pad can support the weight of the heat pump.
See "Weights" on page 27.
l
Elevate the pad enough to allow for drainage.
l
Make sure the pad is flat and level.
l
Have the pad extend at least 6 inches from the heat pump base in all directions.
l
Do not install the heat pump on soil or grass.
l
Do not allow the heat pump base to touch the building's foundation.
l
Do not place the heat pump directly on a concrete floor. This can case noise to be transmitted to an occupied
space. If necessary install vibration dampers between the heat pump base and floor.
l
Equipment pad must meet all requirements of authorities having code-related jurisdiction.
Содержание Heatwave Superquiet TropiCal