Page - 29
HEAT EXCHANGER
TYPE
MODEL
TEMPERATURE
Titanium ThermoLink
®
T090
3° to 6° F
(1.7° C to 3.3° C)
Titanium ThermoLink
®
T115
3° to 7° F
(1.7° C to 3.9° C)
Titanium ThermoLink
®
T135
4° to 8° F
(2.2° C to 4.4° C)
Titanium Tube-in-Tube
T170
3° to 7° F
(1.7° C to 3.9° C)
Titanium Tube-in-Tube
TC500
2° to 5° F
(1.1° C to 2.8° C)
Titanium ThermoLink
®
TC1000
2° to 5° F
(1.1° C to 2.8° C)
Titanium ThermoLink
®
TC1500
3° to 7° F
(1.7° C to 3.9° C)
Table 3 - Temperature Chart
PLEASE NOTE -
l
Temperature differences are based on pool water temperatures of 69° to 75° F. (20.5° to
23.8° C)
l
For water temperatures outside this range, contact AquaCal
®
.
2.7 Planned Maintenance
An annual inspection and maintenance program is strongly recommended starting no later than one year after
installation of the heat pump. In harsh environments or coastal areas, a bi-annual inspection is recommended.
See the recommended inspection checklist.
AquaCal
®
can perform this service in limited areas. Contact Customer Support for more information.
DANGER
Failure to heed the following will result in injury or death.
l
RISK OF ELECTRICAL SHOCK FROM ENERGY STORED IN CAPACITORS - MODELS EQUIPPED
WITH VARIABLE FREQUENCY COMPRESSOR DRIVES STORE ELECTRICITY EVEN AFTER THE
POWER HAS BEEN DEACTIVATED AT THE POWER BREAKER.
Wait for 2 minutes after the shut down
of equipment before servicing.
l
Deactivate power while routing wiring to control board.
l
Follow all National Electric Codes (NEC) and/or State and Local guidelines.
WARNING
Failure to heed the following may result in injury or death.
l
Annual inspection and service must be performed by a qualified heat pump specialist in order to prevent physical
injury or damage to equipment. For tasks requiring handling refrigerant, an HVAC license is required.
2
-
M
ai
nt
ena
nc
e
Содержание HeatWave SuperQuiet SQ120R
Страница 2: ......
Страница 11: ...Page 8 1 Operation ...
Страница 13: ...Page 10 1 Operation ...
Страница 17: ...Page 14 Set Efficiency Mode to 24 Hour 1 Operation ...
Страница 18: ...Page 15 Set Efficiency Mode to Filtration Schedule 1 Operation ...
Страница 19: ...Page 16 1 Operation ...
Страница 21: ...Page 18 Configure for Call mode 1 Operation ...
Страница 22: ...Page 19 Configure for Flex mode 1 Operation ...
Страница 53: ...Page 50 Model Number Example 4 Appendix ...
Страница 58: ......