Page - 28
Temperature Port
(Shown with Probe)
1. Adjust the thermostat to its lowest setting with the unit in
heating mode.
2. Deactivate the water filtration pump.
3. Confirm that the filters leading to the heat pump are clean.
4. Adjust the valves controlling water headed towards the heat
pump to the half-open position.
5. Adjust the valves controlling water leading away from the
heat pump to a fully open position.
6. Activate the pool water filtration pump.
7. Slowly raise the thermostat temperature until the heat pump
activates.
l
After a four-minute delay, the heat pump's compressor will start.
8. With the heat pump running, confirm the filtration pump is operating properly with adequate flow and no short
cycling.
9. Wait for water temperatures to stabilize (approximately 5 minutes).
12. Adjust valves in the following order using the temperature chart provided.
a. Adjust the valve that controls water exiting the heat pump until the correct temperature differential is
achieved. Match the temperature measured with a temperature probe to the chart.
b. Wait for water temperatures to stabilize. Then check the temperature again. Re-adjust the valve as needed.
13. Mark valves at these positions for future reference.
HEAT EXCHANGER
TYPE
MODEL
TEMPERATURE
Titanium ThermoLink
®
SQ120R
3° to 7° F
(1.7° C to 3.9° C)
Titanium ThermoLink
®
SQ125
3° to 7° F
(1.7° C to 3.9° C)
Titanium ThermoLink
®
SQ145
3° to 7° F
(1.7° C to 3.9° C)
Titanium ThermoLink
®
SQ166R
3° to 8° F
(1.7° C to 4.4° C)
Titanium ThermoLink
®
SQ225
4° to 9° F
(2.2° C to 5° C)
Tube-in-Tube
T035
1° to 4° F
(.5° C to 2.2° C)
Tube-in-Tube
T055
2° to 5° F
(1.1° C to 2.8° C)
Tube-in-Tube
T075
3° to 7° F
(1.7° C to 3.9° C)
2
-
M
ai
nt
ena
nc
e
Содержание HeatWave SuperQuiet SQ120R
Страница 2: ......
Страница 11: ...Page 8 1 Operation ...
Страница 13: ...Page 10 1 Operation ...
Страница 17: ...Page 14 Set Efficiency Mode to 24 Hour 1 Operation ...
Страница 18: ...Page 15 Set Efficiency Mode to Filtration Schedule 1 Operation ...
Страница 19: ...Page 16 1 Operation ...
Страница 21: ...Page 18 Configure for Call mode 1 Operation ...
Страница 22: ...Page 19 Configure for Flex mode 1 Operation ...
Страница 53: ...Page 50 Model Number Example 4 Appendix ...
Страница 58: ......