5
Prefabricated swimming pool:
To install a floodlamp in prefabricated swimming pool make a circular hole with a diameter of
240 mm (Fig. 2). Install the housing (no. 12) and one of the adhesive joints (no.18) on the outer side of the pool. Install the
other adhesive joint.
To install the flange (no. 19) on the inner side of the swimming pool, make sure that the heads of the screws DIN 7981 4,8x16,
which have been installed previously (no. 21), coincide with the area reserved for them on the back of the flange.
Secure the flange (no.19) to the pool wall using 16 screws:
DIN 966 M-6 x 24 point (no. 20) if the housing is for screws with metric pitch (Fig, 4).
DIN 7982 5.5 x 25 (no. 20) if the housing is for self-threading screws (Fig. 4).
4. ASSEMBLY:
After installation of the housing and the clamp, if it is a prefabricated swimming pool, assemble the floodlamp.
To connect the floodlamp to the electric power supply insert the cable through the gland seal nut (11). Tighten the gland seal
nut until you can verify that the cable will not yield when you pull on it with your hand.
Take the precaution of leaving 1.5 m of cable wound on the base of the floodlamp (no. 6) in order to be able to remove the
floodlamp to the edge of the pool in the event that lamp replacement or handling is required. (Fig. 5).
Insert the entire floodlamp assembly in the housing (Fig 6). In order to obtain good pool lighting it is important that the anagram
of the decorative ring (no. 1) is located on the upper part (Fig 7).
5. MAINTENANCE:
To remove the lamp, unscrew the 6 nuts (no. 8) which secure the decorative ring (no. 1) to the base of the floodlamp (no. 6)
(Fig. 9).
Remove the lamp (no. 4) from the inside of the base of the floodlamp and disconnect the two terminals, loosening the two
screws which secure them to the Iamp.(Fig. 10).
Change the lamp and assemble the Floodlamp, in the opposite order described in point 4 of assembly, taking special care to:
• Connect the cable terminals to the lamp, using the 2 screws supplied with the lamp (Fig. 11).
• Fully center the 110 x 11 O-ring (no. 5) in its seat.
• Firmly tighten the nuts.
Attention:
•
Before any handling ensure that there is NO voltage supplied to the floodlamp.
• The new lamp should have the same characteristics as that supplied with the floodlamp, PAR56 300 W 12 V.
• In order to ensure full water tightness, clean the seat of the O-ring (no. 6) for the lamp or replace the O-ring if you observe
any notches or permanent damage.
6. START-UP:
Ensure that the voltage the lamp receives is never greater than 12 V.
The floodlamp should only operate underwater while secured to the vertical walls of the pool. Never switch on the floodlamp if
it is not underwater.
SAFETY WARNINGS:
•
The persons who are in charge of assembly should have the required qualifications for this type of work.
• Avoid making contact with the electric voltage.
• Comply with the current standards regarding accident prevention.
• In this regard, the IEC 364-7-702 standards must be observed: WIRING IN BUILDINGS. SPECIAL WIRING. SWIMMING
POOLS.
• Any operation related to the maintenance or replacement of parts should be performed with the floodlamp disconnected from
the electric power system.
• Do not handle with wet feet.
• The manufacturer is not responsible in any circumstances for assembly, installation or start-up of any electric components
which have been inserted or handled at locations other than its own premises.
Содержание STANDARD Series
Страница 5: ...17 Fig 9 Fig 11 Fig 10 Fig 8 ...