AQUA SALT EVO
MAINTENANCE AND INSTRUCTION MANUAL
Salt chlorine generator
ENGLISH
ADSP7000753
rev. 2.0
23/04/2019
63/96
63
3.5
System
activation
When chlorine generator is activated for the first time and the pool contains water without chlorine, we
recommend to run the Boost mode. This operating mode performs a shock chlorination, producing
chlorine at its maximum capacity for 12 hours. The daily chlorine production must be set as a function of
the number of bathers, depending on the water temperature and size of the pool (with the exception of the
proportional operation mode). To activate the chlorine generator, it is necessary to adapt the following
parameters to the configuration of your system:
Cell type: insert the capacity value of your pool's cell (50, 100, 150, 200).
Pool capacity: insert the volume (cu. m) of your pool
Operating mode: choose how to operate the chlorine generator (external timer, proportional, see the
opening pages of the manual).
4 Programming
procedure
To get the best results
from your chlorine generator,
programme
its activity and set the values of its parameters. To do so, the system
comes with a user interface equipped with:
•
Display
•
Keys
•
Led
The system can be also programmed through a software you can
install on your Windows PC.
Picture 9 shows the user interface. We will now see its main
characteristics.
Up/Down
keys modify the numerical values for every menu section and scroll the options of the
sections.
Enter (ENT)
key accesses and exits the submenu sections. By holding it for 1 second from the User
Menu, you will access the Installer Menu. If you hold it from the main sections of a Menu, you will go
back to the parent Menu.
Function (F)
scrolls the sections of the Menus.
Press it for 1 second from the User Menu to access the Programme Start Menu.
C
HLORINATION
P
OWER
-
ON
/S
TATE KEY AND LED
:
Pressing the ON / OFF button enables the production of chlorine, the next press production is disabled.
When the production of chlorine is enabled, the LED is:
▪
Green steady: chlorine production enabled but not running at the moment of viewing;
▪
flashing green: chlorine production enabled and running.
When the chlorine production is disabled the LED is off.
User M
enu
Start
Program
M
enu
Содержание Salt Evo
Страница 92: ...AQUA SALT EVO ADSP7000753 rev 2 0 23 04 2019 92 96 92 11 Pressure switch assembly ...
Страница 93: ...AQUA SALT EVO ADSP7000753 rev 2 0 23 04 2019 93 96 93 12 Connections with other versions ...
Страница 94: ...AQUA SALT EVO ADSP7000753 rev 2 0 23 04 2019 94 96 94 13 Download software ...